122,99 €
An accessible and thorough guide to debonding and fixed retainer bonding Debonding and Fixed Retention in Orthodontics: An Evidence-Based Clinical Guide reviews the protocols, materials, and techniques required at two key stages of orthodontic treatment. The book has been written as a reference guide and the chapters introduce the best-supported and most efficient approaches to each stage of debonding and fixed retainer bonding treatments, from choice of material through to final results. The book includes relevant procedures including orthodontic appliance removal, appliance debonding, the use of rotating instruments, and enamel cleaning. The authors also provide guidance on topics such as the failure and adverse effects of fixed retainers, enamel structural defects, periodontal effects, and aerosol production, to aid in positive result retention. Readers will also find: * Two extensive sections covering debonding and fixed retainer bonding * Evidence-based guidelines for each stage of treatment * Summaries of the side effects of procedures on hard and soft dental tissues * Tips to avoid potential unfavorable sequelae * Detailed lists of existing methods and their clinical implications Debonding and Fixed Retention in Orthodontics is written for orthodontic specialists, clinicians, and postgraduate dental students looking to build knowledge and ensure the best results during these two stages of orthodontic therapy.
Sie lesen das E-Book in den Legimi-Apps auf:
Seitenzahl: 485
Veröffentlichungsjahr: 2023
Cover
Table of Contents
Title Page
Copyright Page
List of Contributors
Preface
Section A: Debonding
1 Cutting with Rotating Instruments and Cutting Efficiency of Burs
1.1 Introduction
1.2 Enamel Surface and Damage Associated with Debonding Techniques: Burs and Polishing
1.3 Preservation and Remineralization
1.4 Clinical Considerations
References
2 Debonding Protocols
2.1 Introduction
2.2 Bond Failure Locations during Debonding
2.3 Protocols for Bracket Removal
2.4 Ultrasonic Debonding
2.5 Electrothermal Debonding
2.6 Use of Lasers for Debonding
2.7 Guidelines from Manufacturers
2.A Appendix: Units for Debonding Stress and Consideration of Debonding Force
References
3 Bonding and Debonding Considerations in Orthodontic Patients Presenting Enamel Structural Defects
3.1 Introduction
3.2 General Considerations and Challenges of Bonding and Debonding Strategies
3.3 Enamel Structural Defects
3.4 Concluding Remarks
References
4 Enamel Colour, Roughness and Gloss Changes after Debonding
4.1 Introduction
4.2 Tooth Colour Changes Associated with Orthodontic Treatment
4.3 Tooth Bleaching Considerations After Debonding
4.4 Enamel Roughness Changes After Debonding
4.5 Tooth Gloss Changes After Debonding
References
5 Aerosol Production during Resin Removal with Rotary Instruments
5.1 Introduction
References
6 Evidence on Airborne Pathogen Management from Aerosol‐Inducing Practices in Dentistry – How to Handle the Risk
6.1 Introduction
6.2 Existing Evidence
6.3 Findings in Context
6.4 Concluding Remarks and Implications for Research
References
7 Future Material Development for Efficient Debonding
7.1 Command‐Debond Adhesives
7.2 BPA‐Free Monomers
7.3 Biomimetic Adhesives
Further Reading
8 The Use of Attachments in Aligner Treatment: Analyzing the ‘Innovation’ of Expanding the Use of Acid Etching‐Mediated Bonding of Composites to Enamel and Its Consequences
8.1 Enamel Involvement
8.2
In Vivo
‐Induced Alterations of Aligners and Attachments
8.3 Release of Compounds
8.4 Debonding and Grinding
8.5 Concluding Remarks
References
Section B: Fixed Retainer Bonding
9 Composite Resins Used for Retainer Bonding
9.1 Introduction
9.2 Hardness
9.3 Wear Resistance
9.4 Bond Strength
9.5 Microleakage
9.6 Water Sorption
9.7 Ageing
References
10 Wires Used in Fixed Retainers
10.1 Introduction
10.2 Desirable Properties of Retainer Wires
10.3 Clinical Selection of Retainer Wire
10.4 Recent Research
References
11 Release of Bisphenol‐A from Materials Used for Fixed Retainer Bonding
11.1 Introduction
11.2 BPA and Fixed Retainers – Clinical Considerations
11.3
In Vitro
Research
11.4 BPA‐Free Orthodontic Adhesives
11.5 Conclusions
References
12 Clinical Effectiveness of Bonded Mandibular Fixed Retainers
12.1 Introduction
12.2 Short‐Term Alignment Stabilisation
12.3 Long‐Term Alignment Stabilisation
12.4 Failure Rates
12.5 Periodontal Effects
12.6 Side Effects of Fixed Retainers – Unwanted Tooth Movement
References
13 Masticatory Forces and Deformation of Fixed Retainers
13.1 Introduction
13.2 Clinical Observations
13.3 Retainer Properties
13.4
In Vitro
Loading of Fixed Retainer Wires
References
Index
End User License Agreement
Chapter 3
Table 3.1 Enamel defects and orthodontics: amelogenesis imperfecta.
Table 3.2 Enamel defects and orthodontics: molar incisor hypomineralisation...
Chapter 4
Table 4.1
In vivo
tooth colour evaluation studies related to orthodontic t...
Table 4.2 Systematic reviews of the effect of orthodontic treatment on toot...
Chapter 6
Table 6.1 Characteristics of the relevant included studies (
n
= 29), in alp...
Table 6.2 League table, indicating network meta‐analysis (NMA) mean differe...
Table 6.3 The ranking probability of each treatment to be considered the 1s...
Table 6.4 Quantitative data from individual single studies for pathogen loa...
Chapter 8
Table 8.1 Effective surface exposure area of adhesive in bracket bonding an...
Table 8.2 Mechanical properties of adhesives and composites used for the fa...
Table 8.3 Mechanical properties (hardness, indentation modulus) of aligner ...
Chapter 9
Table 9.1 Mean values (± standard deviations) of selected mechanical proper...
Table 9.2 Mean values for shear bond strength (SBS), wire pullout resistanc...
Chapter 11
Table 11.1 Descriptive statistics for the results of instrumented indentati...
Chapter 13
Table 13.1 Young's modulus and the Vickers hardness (HV) test results for r...
Table 13.2 Force system during intrusive maximum loading of the anterior te...
Chapter 1
Figure 1.1 (a) Natural tooth; (b) tooth ground with a carbide bur.
Figure 1.2 (a) Natural tooth; (b) tooth ground with a diamond bur.
Figure 1.3 (a) Diamond bur before use; (b) diamond bur after use.
Figure 1.4 Grinding action by diamond burs. (a) During the first step in the...
Figure 1.5 (a) Carbide bur before use; (b) carbide bur after use.
Figure 1.6 (a) Cutting action in a clockwise direction; (b) polishing action...
Figure 1.7 Different types of turbines.
Figure 1.8 Electric motor handpieces.
Figure 1.9 (a) Turbine with one water port; (b) turbine with three water por...
Figure 1.10 Enamel appearance after debonding and polishing with white stone...
Figure 1.11 Enamel appearance after debonding and polishing with a tungsten ...
Figure 1.12 Enamel appearance after debonding and polishing with a tungsten ...
Chapter 4
Figure 4.1 Spectrophotometric recording of an enamel colour defect and an en...
Figure 4.2 The CIELAB colour space.
Figure 4.3 Full shade analysis of an upper‐right canine with reflectance spe...
Figure 4.4 Consecutive spectrophotometric recordings of an upper‐right centr...
Figure 4.5 Spectrophotometric recordings of an orthodontically treated upper...
Figure 4.6 Spectrophotometric recordings of an upper‐left central incisor. (...
Figure 4.7 Enamel wear of lower incisors (SpecroShade Micro; MHT, Zurich, Sw...
Chapter 5
Figure 5.1 A scanning electron microscope image of the various shapes and si...
Figure 5.2 Airborne particles produced during enamel clean‐up landing on the...
Figure 5.3 Airborne splatter particles visible on the operator's protective ...
Figure 5.4 A schematic of the human respiratory system and where particulate...
Figure 5.5 Mucociliary escalator lining the conductive airways of the respir...
Figure 5.6 Bracket debonding pliers being used to remove a metallic bracket ...
Figure 5.7 Schematic of a bracket bonded to the enamel surface. The blades o...
Figure 5.8 Schematic of the bracket base and adhesive resin penetrating the ...
Figure 5.9 Marple Personal Cascade Impactor assembled and disassembled stage...
Figure 5.10 Diagram showing the deposition site of the greatest particulate ...
Figure 5.11 The experimental setup used by Johnston et al. (2009) to test th...
Figure 5.12 Viable impactor with cut‐off stages.
Chapter 6
Figure 6.1 Network plot, with all contributing interventions and their compa...
Figure 6.2 Interval plot, allowing for graphical representation of effect si...
Figure 6.3 Rankograms for the 10 competing interventions. Horizontal axis de...
Chapter 9
Figure 9.1 Abrasive wear of the composite and microleakage six years post‐de...
Figure 9.2 Microleakage and abrasive wear of the composite seven years post‐...
Figure 9.3 Secondary electron and backscattered electron images from the sur...
Figure 9.4 Secondary electron and backscattered electron images from the sur...
Chapter 10
Figure 10.1 Examples of the clinical use of fixed retainers. (a) Multistrand...
Figure 10.2 (a) An example of unexpected tooth movement during the retention...
Figure 10.3 (a) Another example of unexpected tooth movement during the rete...
Figure 10.4 Scanning electron microscope images (insets) and photographs of ...
Figure 10.5 Beta‐titanium rectangular retainer, with the thicker side remain...
Figure 10.6 (a) Virtual computer‐aided design/computer‐aided manufacturing (...
Chapter 11
Figure 11.1 Fixed retainers are commonly used for an extended period or even...
Chapter 12
Figure 12.1 The two types of retainers used in the studies by Renkema et al....
Figure 12.2 The two types of retainers used in the studies by Kocher et al. ...
Figure 12.3 (a) Torque difference between the mandibular central incisors at...
Figure 12.4 (a, b) Excessive torque on the right mandibular canine four year...
Figure 12.5 Deep labial gingival recession at the mandibular left central in...
Chapter 13
Figure 13.1 Deformation of the dead‐soft retainer three years post‐debonding...
Figure 13.2 The orthodontic measurement and simulation system (OMSS).
Figure 13.3 Significant deformation of a retainer with a high degree of anne...
Cover Page
Title Page
Copyright Page
List of Contributors
Preface
Table of Contents
Begin Reading
Index
WILEY END USER LICENSE AGREEMENT
iii
iv
xiii
xiv
xv
xvii
xviii
1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
Edited by
Theodore Eliades
DDS, MS, Dr Med Sci, PhD, DSc, FIMMM, FRSC, FInstP, FDS RCS(Ed)Professor and Director, Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine,University of Zurich, Switzerland
Christos Katsaros
DDS, Dr med dent, Dr hc, Odont Dr/PhDProfessor and Chair, Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine/Medical Faculty,University of Bern, Switzerland
This edition first published 2024© 2024 John Wiley & Sons Ltd
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, except as permitted by law. Advice on how to obtain permission to reuse material from this title is available at http://www.wiley.com/go/permissions.
The right of Theodore Eliades and Christos Katsaros to be identified as the authors of the editorial material in this work has been asserted in accordance with law.
Registered OfficesJohn Wiley & Sons, Inc., 111 River Street, Hoboken, NJ 07030, USAJohn Wiley & Sons Ltd, The Atrium, Southern Gate, Chichester, West Sussex, PO19 8SQ, UK
For details of our global editorial offices, customer services, and more information about Wiley products visit us at www.wiley.com.
Wiley also publishes its books in a variety of electronic formats and by print‐on‐demand. Some content that appears in standard print versions of this book may not be available in other formats.
Trademarks: Wiley and the Wiley logo are trademarks or registered trademarks of John Wiley & Sons, Inc. and/or its affiliates in the United States and other countries and may not be used without written permission. All other trademarks are the property of their respective owners. John Wiley & Sons, Inc. is not associated with any product or vendor mentioned in this book.
Limit of Liability/Disclaimer of WarrantyThe contents of this work are intended to further general scientific research, understanding, and discussion only and are not intended and should not be relied upon as recommending or promoting scientific method, diagnosis, or treatment by physicians for any particular patient. In view of ongoing research, equipment modifications, changes in governmental regulations, and the constant flow of information relating to the use of medicines, equipment, and devices, the reader is urged to review and evaluate the information provided in the package insert or instructions for each medicine, equipment, or device for, among other things, any changes in the instructions or indication of usage and for added warnings and precautions. While the publisher and authors have used their best efforts in preparing this work, they make no representations or warranties with respect to the accuracy or completeness of the contents of this work and specifically disclaim all warranties, including without limitation any implied warranties of merchantability or fitness for a particular purpose. No warranty may be created or extended by sales representatives, written sales materials or promotional statements for this work. The fact that an organization, website, or product is referred to in this work as a citation and/or potential source of further information does not mean that the publisher and authors endorse the information or services the organization, website, or product may provide or recommendations it may make. This work is sold with the understanding that the publisher is not engaged in rendering professional services. The advice and strategies contained herein may not be suitable for your situation. You should consult with a specialist where appropriate. Further, readers should be aware that websites listed in this work may have changed or disappeared between when this work was written and when it is read. Neither the publisher nor authors shall be liable for any loss of profit or any other commercial damages, including but not limited to special, incidental, consequential, or other damages.
Library of Congress Cataloging‐in‐Publication DataNames: Eliades, Theodore, editor. | Katsaros, Christos, editor.Title: Debonding and fixed retention in orthodontics : an evidence‐based clinical guide / edited by Theodore Eliades, Christos Katsaros.Description: Hoboken, NJ : Wiley‐Blackwell, 2024. | Includes bibliographic references and index.Identifiers: LCCN 2022059886 (print) | LCCN 2022059887 (ebook) | ISBN 9781119623953 (hardback) | ISBN 9781119623960 (adobe pdf) | ISBN 9781119623977 (epub)Subjects: MESH: Dental Debonding–methods | Dental Debonding–adverseeffects | Orthodontic Appliances, Fixed | Dental EnamelClassification: LCC RK521 (print) | LCC RK521 (ebook) | NLM WU 192 | DDC 617.6/43–dc23/eng/20230429LC record available at https://lccn.loc.gov/2022059886LC ebook record available at https://lccn.loc.gov/2022059887
Cover Design: WileyCover Image: © Dr. Andreas Karamouzos, Dr. Effimia Koumpia and Dr. Anastasios A. Zafeiriadis
María ArreguiDepartment of OdontologyFaculty of DentistryUniversitat Internacional de CatalunyaSant Cugat del VallesBarcelona, Spain
Georgios N. BelibasakisDepartment of Dental MedicineKarolinska InstitutetHuddinge, Sweden
Christoph BourauelDepartment of Oral TechnologySchool of DentistryUniversity Hospital BonnBonn, Germany
T. Gerald BradleySchool of DentistryUniversity of LouisvilleLouisville, Kentucky, USA
William BrantleyDivision of Restorative and Prosthetic DentistryCollege of DentistryThe Ohio State UniversityColumbus, OH, USA
Christian J. DayDepartment of Orthodontics Bristol Dental SchoolUniversity of BristolBristol, UK
Theodore EliadesClinic of Orthodontics and Pediatric DentistryCenter of Dental MedicineUniversity of ZürichZürich, Switzerland
Teresa FloresDepartment of Orthodontics Faculty of DentistryUniversitat Internacional de CatalunyaSant Cugat del VallesBarcelona, Spain
Lluís Giner‐TarridaDepartment of Odontology Faculty of DentistryUniversitat Internacional de CatalunyaSant Cugat del VallesBarcelona, Spain
Angélica IglesiasDepartment of Orthodontics Faculty of DentistryUniversitat Internacional de CatalunyaSant Cugat del VallesBarcelona, Spain
Masahiro IijimaDivision of Orthodontics and Dentofacial OrthopedicsDepartment of Oral Growth and DevelopmentHealth Sciences University of HokkaidoIshikari, Tobetsu, Hokkaido, Japan
Anthony J. IrelandDepartment of Orthodontics Bristol Dental SchoolUniversity of Bristol, Bristol, UK
Andreas KaramouzosDepartment of Orthodontics Faculty of DentistrySchool of Health SciencesAristotle University of ThessalonikiThessaloniki, Greece
Christos KatsarosDepartment of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine/Medical FacultyUniversity of BernBern, Switzerland
Katerina KavvadiaDepartment of DentistrySchool of MedicineEuropean University CyprusNicosia, Cyprus
Dimitrios KloukosDepartment of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine/Medical FacultyUniversity of BernBern, Switzerland
Despina KoletsiClinic of Orthodontics and Pediatric DentistryCenter of Dental MedicineUniversity of ZürichZürich, Switzerland
Effimia KoumpiaDepartment of Orthodontics Faculty of DentistrySchool of Health SciencesAristotle University of ThessalonikiThessaloniki, Greece
Thaleia KouskouraDepartment of Pediatric Oral Health and OrthodonticsUniversity Center for Dental Medicine, University of BaselBasel, Switzerland
Spyridon N. PapageorgiouClinic of Orthodontics and Pediatric DentistryCenter of Dental MedicineUniversity of ZürichZürich, Switzerland
Pawel PazeraDepartment of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine/Medical FacultyUniversity of BernBern, Switzerland
Andreu PuigdollersDepartment of OrthodonticsFaculty of DentistryUniversitat Internacional de CatalunyaSant Cugat del VallesBarcelona, Spain
Jonathan R. SandyDepartment of OrthodonticsBristol Dental SchoolUniversity of BristolBristol, UK
Iosif SifakakisDepartment of OrthodonticsSchool of DentistryNational and KapodistrianUniversity of AthensAthens, Greece
Eser TüfekçiDepartment of OrthodonticsSchool of DentistryVirginia Commonwealth UniversityRichmond, VA, USA
Anastasios A. ZafeiriadisDepartment of OrthodonticsFaculty of DentistrySchool of Health SciencesAristotle University of ThessalonikiThessaloniki, Greece
The completion of orthodontic treatment includes two important phases, which have not received the proper attention in the broader orthodontic literature and are therefore highly individualized, empirically driven and with limited evidence: debonding and fixed retainer bonding.
The first includes the detachment of the orthodontic appliance from the enamel and the subsequent grinding of the adhesive layer (or, more recently, the thick composite attachment block used in aligners). This stage entails a relatively large number of materials and processes that are influenced by the bonding process, because etching‐mediated bonding results in a more cumbersome and catastrophic debonding procedure than glass‐ionomer bonding, for example. Depending on the composition of the appliance used, this process includes using debonding pliers or ultrasound, laser or heat probes to detach the bracket; many types of burs with different cutting efficiencies in slow‐ or high‐speed handpieces and an array of polishing tools are also used.
Fixed retainer bonding includes many types of wires and configurations bonded with various types of composite resins requiring different handling, even for the same materials. Some side effects have been reported related to the placement technique or the wire activation over time: the coaxial wires used have a significant resilience and therefore store a recoverable elastic deformation, which is then given back to the wire‐adhesive‐tooth complex, resulting in either fracture of the wire‐adhesive interface or unwanted tooth movement.
For this plethora of materials, instruments and handling modes, the information transferred to the trainee or practicing clinician is often dictated by the bias of the supervising instructor for postgraduate students or the content of relevant weekend courses – the sort that have saturated the professional community – rather than the result of an evidence‐based approach.
The objective of this textbook is to provide succinic and clinically relevant information on the underlying mechanisms of success or failure for these two fundamental phases of treatment. The book is structured around two axes: debonding and resin grinding, and fixed retainer placement.
The first section covers aspects of the topic that have not yet been found in relevant texts, including methods of appliance removal, cutting efficiency of burs, grinding and enamel effects, complicated interfacial characteristics of attachments with enamel and aligners, airborne pathogens and aerosol produced during resin grinding, and future materials utilizing biomimetic approaches for bonding, among others.
The second section provides an analysis of the materials utilized in fixed retainer bonding, with emphasis on resin, wires, their effect on material deformation during mastication or placement, and release of bisphenol‐A from fixed retainer resin adhesives, as well as clinical effectiveness and unwanted effects of fixed retainers on tooth position.
We hope the book will serve as a source of information serving education and practice alike.
Theodore Eliades
Christos Katsaros
María Arregui1, Lluís Giner‐Tarrida1, Teresa Flores2, Angélica Iglesias2, and Andreu Puigdollers2
1 Department of Odontology, Faculty of Dentistry, Universitat Internacional de Catalunya, Sant Cugat del Valles, Barcelona, Spain
2 Department of Orthodontics, Faculty of Dentistry, Universitat Internacional de Catalunya, Sant Cugat del Valles, Barcelona, Spain
The retention phase is a crucial part of orthodontic treatment. Its importance keeps increasing since patients look for a long‐lasting ‘perfect’ result for aesthetic reasons, even though some degree of relapse is always expected. For this reason, life‐long retention is more commonly advised every day by clinicians (Padmos et al. 2018).
Many studies have analysed the retention phase in terms of stability, retention material, adhesion, clinician and patient preference and hygiene (Al‐Moghrabi et al. 2018; Eroglu et al. 2019; Gugger et al. 2016; Sifakakis et al. 2017), but none of the literature has focused on the consequences of retention on the enamel. Unlike bracket debonding, the detachment of lingual retainers is usually accidental and may be caused by excessive force, adhesive material wear or retainer rupture. The enamel could be altered due to the applied load that caused the rupture in the adhesive interphase or the removal of remaining adhesive or retainer materials (Ryf et al. 2012).
Cleaning and polishing procedures for remnants of adhesive materials are as variable as retention protocols. No consensus has been reached on the ideal protocol for adhesive removal (Janiszewska‐Olszowska et al. 2014). The various techniques include using hand instruments, rotatory instruments (high‐ and low‐speed), sandblasting, ultrasound and bur and disc materials including tungsten carbide burs, diamond burs, composite burs, rubber burs and Sof‐Lex discs (Eliades 2019; Janiszewska‐Olszowska et al. 2015; Shah et al. 2019). This is a critical moment, as the aim is to remove the material with no or minimal damage to the enamel structure and without overheating the pulp due to friction caused by the instruments. To do so, it is extremely important to carefully select the burs and rotary instruments to be used. For this reason, it is important to have a good understanding of the cutting efficiency of the burs, which type of bur is most suitable, the bur's longevity and the maximum number of uses due to loss of effectiveness. It is also important to take into account the characteristics of the rotating instruments: rotational speed, torque or power, water spray coolant, etc., to avoid damaging the tooth.
In this chapter, we will discuss aspects of the retention phase concerning enamel preservation and the consequences of temporarily adhesive procedures, such as appliances bonding, on the enamel surface. We will analyse the repercussions of adhesive procedures for retention materials, especially considering that life‐long retention may require one or more rebonding procedures (Jin et al. 2018). We will also deal with the correct selection of burs for the removal of cement from brackets and fixed retainers; the subsequent final finishing with polishing tools to help recover the enamel aesthetics; and the most advisable protocol for removing fixed retainers, whether for final removal or for a rebonding procedure.
Thanks to advanced microscopy technology and mineral property analysis techniques, the composition of enamel and its properties before and after adhesive treatments have been widely studied. The vast majority of studies are based on the vestibular surface because there is significant concern about enamel preservation due to aesthetic concerns. However, more aggressive bonding techniques are often used on the lingual surface because this surface does not have aesthetical importance. Such studies are usually done on labial surfaces; it is not common to do them on lingual surfaces.
An in vitro study using a scanning electron microscope (SEM) found an important difference between the two enamel surfaces. The lingual surface appears to be smoother, with smaller micropores and a less pronounced wavelike appearance after conditioning, which resulted in less mechanical interlocking in the enamel‐bonding interphase and, thus, lower shear bond strength (SBS) values and greater tooth damage compared to the buccal side (Brosh et al. 2005). This interesting data is rarely discussed when adhesion protocols for retainers or lingual brackets are presented.
Sufficient bonding strength, easy debonding and limited damage to the enamel surface are critical factors in orthodontics (Shinya et al. 2008). A lower enamel Adhesive Remnant Index (ARI) after cleaning of residual adhesive corresponds to less damage to the enamel surface (David et al. 2002; Fjeld and Ogaard 2006). Removal systems are important not only for enamel preservation after appliance removal but also in lingual retention: the polishing phase is crucial for patient comfort because studies show that patients' tongues can detect changes in surface roughness (SR) of less than 1 μm (Jones et al. 2004). Furthermore, the smoother surface helps reduce the amount of bacterial plaque deposited.
Before selecting instruments, some basic concepts related to burs must be considered: cutting, grinding, and finishing and polishing actions. Cutting is a unidirectional action related to instruments with blades, such as tungsten carbide burs. Depending on the number of blades, the bur will have more of a cutting or polishing function. Also, if we use a low‐speed handpiece, by allowing a change of rotation, we can obtain a greater polishing effect rather than cutting. It has been seen that tungsten carbide burs can leave a regular pattern on the enamel structure (Figure 1.1). The grinding action is responsible for removing small particles from the surface by the effect of abrasive wear, and their action is unidirectional. Diamond burs are an example (Figure 1.2). Different types of diamond burs are available depending on the size of the component particles. During the finishing and polishing phase, the use of tungsten carbide burs with more blades or diamond burs with fine grit is indicated to give the final texture to the surface. Polishing gives a gloss to the enamel, which regains its usual brightness after the cement is removed and becomes smooth and homogeneous. This final part of the polishing process is usually carried out with abrasive instruments such as rubber cups, discs, strips and fine‐grained polishing pastes (Anusavice 2013).
Figure 1.1 (a) Natural tooth; (b) tooth ground with a carbide bur.
Figure 1.2 (a) Natural tooth; (b) tooth ground with a diamond bur.
To remove cement properly, it is important to take into account the cutting efficiency of the burs, which is defined as the maximum capacity to remove dental tissue with the minimum effort during a specific period of time (Choi et al. 2010). It is measured and evaluated by calculating the amount of substrate removed (by weight or length of the cut) in a given time. Many studies have observed a reduction in cutting efficiency after repeated use of burs (Bae et al. 2014).
This reduction of cutting efficiency is associated with factors such as (i) wear of the burs due to use and friction, (ii) debris clogging the bur surface, and (iii) the procedures for cleaning, disinfecting and sterilizing the burs. Some studies have determined that cutting efficiency decreases between the first and the sixth sterilization cycles (Bae et al. 2014; Emir et al. 2018; Regev et al. 2010). Firoozmand et al. (2008) determined that the lifetime of a bur is five uses, since after that it is difficult to guarantee a proper and efficient cut. These results were confirmed by Emir et al. (2018).
The selection of diamond burs should focus on constant cutting efficiency throughout their life span because studies have shown that these burs tend to lose their efficiency due to use (Bae et al. 2014; Emir et al. 2018; Prithviraj et al. 2017). One of the factors related to the reduction in cutting efficiency is the pull‐out of diamond chips (Bae et al. 2014; Pilcher et al. 2000; Prithviraj et al. 2017) (Figure 1.3).
Manufacturers use various methods to adhere abrasive particles to the bur shaft, such as electrodepositing a nickel coating on diamond chips (Ben‐Hanan et al. 2008; Siegel and Anthony Von Fraunhofer 1998), electrodepositing a chrome‐nickel coating (Regev et al. 2010; Siegel and Anthony Von Fraunhofer 1998), sintering, microabrasion (Prithviraj et al. 2017; Siegel and Anthony Von Fraunhofer 1998; Siegel and Von Fraunhofer 1996) and chemical vapour deposition (Jackson et al. 2004). The quality of diamond burs is based on the concentration of abrasive particles and the capacity of the adhesive system to retain the diamond particles during continuous use.
Figure 1.3 (a) Diamond bur before use; (b) diamond bur after use.
The diamond particles used in burs vary between manufacturers, and the primary characteristics are (i) whether the diamonds are natural or synthetic, (ii) their size and shape, and (iii) the individual features of burs. Natural diamonds have more irregular shapes than synthetic ones, which facilitates their deposition in a nickel or chrome‐nickel coating matrix. The size of the diamond chips determines the thickness and category of the burs: ultrafine, fine, medium or coarse (Siegel and Anthony Von Fraunhofer 1998). In cutting efficiency studies, medium grit (120–140 μm) or coarse grit (150–160 μm) burs are generally used. Fine and ultra‐fine grit burs are not usually evaluated in the literature, as their use is more indicated for finishing and polishing.
The cutting and grinding actions of diamond burs are caused by friction. Every movement of the bur in both directions removes tissue with the abrasive action of the sharp edges of the diamond chips (Figure 1.4).
Tungsten carbide burs are composed of 8 to 40 blades (Figure 1.5); the most frequently used have 8, 12, 20 or 40 blades and are indicated for contouring and smoothing various dental materials and structures (Jefferies 2007). These burs generally are characterised by their hardness and cutting edge, but they wear out with each use and are also fragile and susceptible to fracture (Di Cristofaro et al. 2013).
Figure 1.4 Grinding action by diamond burs. (a) During the first step in the grinding process, the bur starts to remove tissue. (b) Every movement of the bur in both directions removes tissue by abrasive action.
Figure 1.5 (a) Carbide bur before use; (b) carbide bur after use.
Figure 1.6 (a) Cutting action in a clockwise direction; (b) polishing action in a counterclockwise direction.
Tungsten carbide burs have a bidirectional cut so that when the burs are rotated in a clockwise direction, they have a cutting action. In a counterclockwise direction, they have a polishing action such that a regular pattern is observed on the tooth structure, corresponding to the ordered arrangement of the blades on the bur (Figure 1.6).
Burs with fewer blades are normally used for cutting and grinding, while those with more blades are used to finish polishing and provide texture, as they have a less aggressive effect on the enamel surface.
Carbide burs are considered the gold standard in the literature for removing orthodontic cement during the debonding procedure because they are faster and more effective than other tools that can be used in this stage. But there is always a risk of removing part of the enamel and altering the external surface, in which case the enamel will not recover its original external roughness (Bosco et al. 2020).
Cutting efficiency can be defined as the amount of substrate removed in a specific period. A long cutting time means lower cutting efficiency (Bae et al. 2014).
This efficiency depends on several factors, such as (i) the type of burs used (diamond or carbide); (ii) the cutting instrument, which may be a turbine or an electric motor handpiece; (iii) the water flow (to remove debris that is clogging the burs and control the intra‐pulp temperature); (iv) the force applied by the operator; and (v) the substrate.
Studies usually compare carbide burs with each other and with diamond burs. Diamond burs are also compared with each other, comparing different particle sizes, usually medium (120–140 μm) or coarse (150–160 μm) grit, with different designs (channelled or conventional) and shapes (chamfered or thin taper).
In general, carbide burs have good cutting efficiency; it is greater in burs with deep angles and sharp edges (Di Cristofaro et al. 2013). Another factor that improves cutting efficiency is a negative cutting angle: it makes the bur more effective because it reduces debris that clogs the bur and interferes with cutting and speed. Some studies observe that carbide burs are faster and more effective than diamond burs (Ercoli et al. 2009); this may be due to their hardness and cutting edge compared to the hardness of the metal that acts as a binder for diamond chips. However, other publications consider diamond burs to have a higher cutting efficiency than carbide burs (Emir et al. 2018).
All diamond burs exhibit similar behaviour: the greatest loss of efficiency occurs between the first and second cuts, after which it decreases progressively (Bae et al. 2014; Pilcher et al. 2000). This is due to wear of the burs during use.
The cutting performance of this type of burs primarily depends on the diamonds. Natural diamonds have irregular shapes with sharper edges, so the most effective burs have a higher proportion of natural diamonds (Prithviraj et al. 2017; Siegel and Von Fraunhofer 1996, 1999). Other factors are the size and diameter of the diamond chips. Larger grit means the bur has greater cutting efficiency. However, studies show that burs with medium and coarse grit often do not differ in their cutting efficiency. This may be because manufacturers assign a category to their burs, such as medium grit; then, when studies analyse the burs with a SEM and measure the diamond chips, the diamonds are observed to be larger and correspond more closely to the coarse size described by the ISO standard (Bae et al. 2014; Prithviraj et al. 2017). In general, these differences between manufacturer classifications and the analysis during studies may be due to the filters used in the manufacturing process to standardise the grit allowing a range of sizes to pass through, so that sometimes particles with greater diameters are introduced.
Cutting efficiency is compromised when diamond chips are pulled out of the binder with which they are attached to the bur shaft rather than by the wear of the diamond cutting edge (Bae et al. 2014; Ben‐Hanan et al. 2008; Emir et al. 2018; Prithviraj et al. 2017). The extent to which diamonds can be pulled out is associated with the properties of the metal used as a binder (Bae et al. 2014) or the system used to bond the diamonds to the bur. The chips are less likely to be detached when the binder is more powerful and has higher adhesion properties, and therefore the bur has greater cutting efficiency. It has also been seen that burs that use nickel electroplating have lower cutting efficiency than burs that use a proprietary brazing system (PBS) (Prithviraj et al. 2017). SEM studies of burs processed by means of electrodeposition with nickel have observed that spaces are left by detached diamond chips; in addition, some diamond chips are embedded too far into the metal matrix, leaving fewer cutting edges exposed and providing less area for cutting (Prithviraj et al. 2017). Another factor that can affect cutting efficiency is a secondary effect of spaces left by diamonds when they are clogged with debris. This effect reduces the effective work of the burs, which is why it is important to cool them properly during grinding or polishing so the water removes this debris (Ben‐Hanan et al. 2008).
The design and shape of diamond burs also influence their cutting efficiency. Some studies have compared chamfered and thin‐taper burs and observed that burs with a larger diameter (chamfered) have a larger cutting area, greater peripheral speed, and higher cutting efficiency than thinner burs (Bae et al. 2014). However, it has been observed that chamfered burs produce a larger temperature increase due to greater friction. Other studies have compared conventional and channelled burs and observed that conventional burs have a higher cutting efficiency than channelled burs (Funkenbusch et al. 2016). It has been seen that grooved burs allow a better distribution of water along the bur between the grooves, providing constant cleaning and reducing clogging debris in the bur, and also achieve faster heat dissipation (Galindo et al. 2004), but no statistically significant differences were observed compared to conventional burs (Ercoli et al. 2009).
The effect of cleaning, disinfecting and sterilisation on the cutting efficiency of burs has also been studied, and some studies concluded that these procedures do not directly affect cutting efficiency (Bae et al. 2014). However, other authors have observed that cleaning and sterilising burs that are used repeatedly improved their cutting behaviour because debris is eliminated during the cleaning procedure (Rotella et al. 2014).
Some studies have evaluated whether bur wear affects the SR the burs cause on the tooth structure or materials as well as cutting efficiency. It seems that the more worn the bur is, the lower the cutting efficiency and SR. The loss of roughness may be heterogeneous, but it can affect the bonding process (Emir et al. 2018). When studying different materials, it is observed that the cutting efficiency of burs used to cut zirconium or lithium disilicate or metals is reduced more rapidly since those materials have harder surfaces than the tooth structure (Emir et al. 2018; Galindo et al. 2004; Nakamura et al. 2015; Siegel and Von Fraunhofer 1996).
In summary, the cutting efficiency of carbide burs is reduced due to wear and tear on the blades (Di Cristofaro et al. 2013). On the other hand, in diamond burs, the factors that influence wear and cutting efficiency are (i) diamond chips being pulled out, (ii) wear of the cutting edges of the diamond chips, (iii) debris clogging the cutting areas, and (iv) wear of the material that acts as a binding agent for the diamond chips on the shank (Ben‐Hanan et al. 2008).
For more than 50 years, turbines have been used in dentistry to grind or polish dental structures and materials because of their performance: (i) they are ergonomic and lightweight, (ii) they are reasonably priced, and (iii) they can quickly remove tooth structure. On the other hand, turbines have these disadvantages: (i) vibration and noise, (ii) the release of aerosols, and (iii) low torque, which causes them to slow down when too much force is detected and decreases cutting capacity – a turbine can even get stuck and stop (Choi et al. 2010; Eikenberg 2001; Ercoli et al. 2009; Kenyon et al. 2005; Rotella et al. 2014) (Figure 1.7).
Figure 1.7 Different types of turbines.
Figure 1.8 Electric motor handpieces.
Electric motor handpieces were developed 20 or 30 years ago. They are characterised by their variable power and higher torque than turbines and therefore maintain their rotation speed with less risk of getting stuck when more force is applied than usual. Other positive aspects of these instruments are that (i) they are quieter and have less vibration; (ii) they release fewer aerosols, reducing the risk of cross‐contamination; and (iii) they provide more precise and concentric cuts than turbines. On the other hand, electric motor handpieces weigh more, making them less ergonomic than turbines (Choi et al. 2010; Eikenberg 2001; Ercoli et al. 2009; Kenyon et al. 2005; Rotella et al. 2014) (Figure 1.8).
Studies have been carried out to compare cutting efficiency depending on the cutting instrument used: turbine or electric motor handpiece. All the studies came to the same conclusion – that the electric motor handpiece had a higher cutting efficiency than the turbine – although no statistically significant differences were observed (Choi et al. 2010; Eikenberg 2001; Ercoli et al. 2009; Rotella et al. 2014). All the authors believe the reason is the difference in torque: the high torque of the electric motor handpiece means its rotational speed is not reduced when more force is applied (Choi et al. 2010; Eikenberg 2001; Ercoli et al. 2009; Rotella et al. 2014). Choi et al. (2010) even add that the difference could be related to the increased weight of the electric motor handpiece, which may cause the dentist to apply slightly more force (without being aware of it), making the instrument more efficient.
Not only is the electric motor handpiece more efficient than the turbine, but a smoother surface is obtained. In contrast, rough marks can be seen from the effect of a turbine, which may be related to loss of speed and possible stall caused by low torque (Geminiani et al. 2014).
As previously mentioned, various factors reduce cutting efficiency, including water flow, which depends on the instruments, and applied force, which depends on both the instrument and the dentist.
Water flow is a very important factor since it removes debris that may remain attached to the bur and avoids iatrogenic injury caused by heat generated during preparation of the tooth (most of the energy that is not used is transformed into heat). The amount of heat transmitted to the tooth usually depends on the type of bur, applied force, cutting time and rate, cooling technique, speed, and torque of the instrument (Galindo et al. 2004).
Most studies that have measured the effect of water flow on the temperature inside the pulp chamber have observed that grinding does not affect the pulp chamber because the water‐flow coolant helps to decrease the temperature and prevent the pulp from reaching a critical temperatures. The water flow indicated in these studies to prevent an increase in pulp temperature is between 25 and 50 ml/min, regardless of whether the bur is made of diamond or carbide. More water is always better to cool the tooth preparation (Ercoli et al. 2009; Galindo et al. 2004; Siegel and von Fraunhofer 2000; Siegel and Patel 2016; Von Fraunhofer and Siegel 2000).
The importance of water flow is based on the number and distribution of water outlets on the instruments (Ercoli et al. 2009; Siegel and Von Fraunhofer 2002). Earlier turbines (and some of today's turbines) had only one water port at the base of the head, so the bur was not fully cooled. Today, electric motor handpieces and modern turbines have three or four water ports (Figure 1.9), increasing the water flow of the entire bur. This allows control over the temperature, increases the removal of debris, and therefore increases cutting efficiency. Studies have compared the efficiency of dry and wet cutting and concluded that wet cutting increases the cutting rate and removes three times more tissue than dry cutting (Ercoli et al. 2009).
Figure 1.9 (a) Turbine with one water port; (b) turbine with three water ports; (c) turbine with four water ports; and (d) electric motor handpiece with three water ports.
The last important factor related to cutting efficiency is the force applied when preparing the tooth. Different authors have conducted studies with dentists to determine the force they apply. Elias et al. (2003) determined that the force varied between 0.66 and 2.23 N, and Siegel et al. (Siegel and Von Fraunhofer 1997, 1999) concluded that the most effective force for medium‐grit burs is 0.92 N. Most literature considers that dentists exert a force between 50 and 150 g when preparing a tooth (Eikenberg 2001; Galindo et al. 2004; Siegel and Von Fraunhofer 1997, 1999). Elias et al. (2003) concluded that the magnitude of the force depends more on the power of the rotating instrument than on the speed of the instrument or outside force applied by the operator. On the other hand, Funkenbusch et al. (2016) consider that greater force applied by the operator generally increases cutting efficiency, so we can observe that there is no consensus about whether force depends more on the instrument or the operator. In summary, all studies consider that as the burs wear out and cutting efficiency is reduced, the force applied by the operator increases, leading to a risk of raising the temperature if there is not proper water flow (Emir et al. 2018; Pilcher et al. 2000; Rotella et al. 2014; Siegel and Von Fraunhofer 1996).
In adhesion protocols, many properties must be taken into account: the chemical nature of the substrates to be joined, the state of the surfaces (cleaning, oxidation, passivation, etc.), their roughness (in relation to previous preparations such as carving, milling, roughing, casting, micro‐etching, etc.), the relationship between the energy surface of the substrate to be bonded and that of the adhesive, wettability between the adhesive and the surface or substrate, adhesive viscosity, liquid transformation, strength of the adhesive, dimensional changes of the adhesive during this transformation, strength and toughness (cohesion) of the cured adhesive and film thickness of the adhesive agent.
When fixed lingual retention is selected, many of these variables must be considered. For example, a smoother lingual surface may require a more aggressive pretreatment or a longer acid‐etching exposure to ensure mechanical porosity and greater resistance to debonding.
Another important aspect of fixed retention is the increasing preference of clinicians for life‐long retention, which will also affect the bonding procedure. Since adhesion in orthodontics is almost always temporary, when looking for definitive bonding, some aspects of the protocol must be revised.
Regarding the retainer itself, there is no consensus among practitioners about adequate stiffness or properties of the material. These are influenced by the clinician's experience, training and beliefs. However, most agree about the use of a fluid composite resin with an acid‐etching‐priming procedure for adhesion.
The consequences of a permanent adhesive technique become evident when rupture, debonding or fracture of the interphase of the retainer occurs. In this case, we encounter damage from the mechanical removal of adhesive remnants and additional chemical damage from the rebonding procedure.
Disruption of the demineralization/remineralization balance in teeth can lead to irreversible structural damage, as adult enamel cannot self‐regenerate (Yamaguchi et al. 2006). Removal of lingual retainer, orthodontic brackets and residual cement causes inevitable enamel loss that is irreversible by biological mechanisms (Pus et al. 1980). This loss can be minimised by carefully selecting less aggressive removal processes. However, any enamel repair must be induced by external methods (Eisenburger et al. 2001), which should be instituted as soon as possible after orthodontic appliance removal.
Reported amounts of enamel loss after bracket debonding and cleaning are highly variable, ranging from 5–10 μm (Zachrisson and Arthun 1979) to 29.5–41.2 μm (Pus et al. 1980). This high variability may be attributed to differences in the methods used for remnants, bracket bonding (self‐etching versus conventional etching cement and direct versus indirect bonding) (Flores et al. 2015; Iglesias et al. 2020; Mielczarek and Michalik 2014) or analysis (weight comparison, surfometry [Hosein et al. 2004], profilometry [Pus et al. 1980], SEM [Fjeld and Ogaard 2006]). A significant loss of enamel volume is observed in premolars subjected to simulated orthodontic treatment compared to untreated enamel. Enamel loss can be reversed, but not completely recovered, by remineralization with toothpaste. This finding may be attributable to the rapid decrease in fluoride release over time (Hahnel et al. 2014).
Recently, research done at the Orthodontics Department of Universitat Internacional de Catalunya compared different removal techniques (specifically after retention debonding) and found higher levels of rugosity (Sa, Sq, Sz) of the enamel in samples to which a high‐speed white stone was applied (Figure 1.10). Tungsten burs were also tested at high and low speeds (Figures 1.11 and 1.12), with 15‐blade burs, and the results showed less damage of the enamel when using a tungsten bur at low speed. This protocol of low‐speed tungsten bur and posterior polishing with rubber cups was applied in accordance with other studies that analysed similar parameters after bracket debonding (Ireland et al. 2005).
Figure 1.10 Enamel appearance after debonding and polishing with white stone using a high‐speed handpiece.
Figure 1.11 Enamel appearance after debonding and polishing with a tungsten carbide bur using a high‐speed handpiece.
Figure 1.12 Enamel appearance after debonding and polishing with a tungsten carbide bur using a low‐speed handpiece.
Researchers have examined the potential use of toothpaste containing surface (S) prereacted glass‐ionomer (PRG) filler (Flores et al. 2017; Ikemura et al. 2008) based on calcium phosphate (Cochrane et al. 2010) or a novel fluoride‐containing bioactive glass (Coceska et al. 2016) for inhibiting demineralization and recovering enamel loss (Fujimoto et al. 2010). In aqueous environments, PRG forms a stable glass‐ionomer phase via a reaction between polyacrylic acid and fluoride‐containing glass (Ikemura et al. 2008). The buffering action of S‐PRG reduces the acidity of the oral environment (Fujimoto et al. 2010; Iijima et al. 2014; Ikemura et al. 2008). Furthermore, S‐PRG filler releases strontium and fluorine ions, which improve the acid resistance of teeth by reacting with hydroxyapatite (Featherstone et al. 1983). More novel investigations have focused on the study of biometric hydroxyapatite toothpaste as a preventive measure in remineralization cases (Bossù et al. 2019; Memarpour et al. 2019).
Nanometric techniques permit three‐dimensional data to be obtained with minimum sample preparation (Hashimoto et al. 2013). Reports of nanometric studies of healthy and affected enamel have described the enamel topography and SR.
SR affects the aesthetic properties, bacterial adhesion and plaque formation of enamel by altering the pathogenic environment (Elkassas and Arafa 2014; Kaga et al. 2014). Researchers have analysed the enamel SR using atomic force microscopy (AFM) and SEM as nanometric techniques. In contrast to SEM, AFM does not dehydrate the surface enamel during sample preparation (Bitter 1998; Keszthelyi and Jenei 1999). Similar to AFM, confocal microscopy (CFM) and profilometry are noninvasive nanometric techniques that enable the quantification of SR parameters with high measurement sensitivity and without altering the enamel surface quality (Poggio et al. 2012).
In a recent study (Iijima et al. 2014), toothpaste containing 5 or 30% S‐PRG offered greater enamel remineralization than NaF‐containing toothpaste, as indicated by the improved surface hardness and elastic modulus values. Remineralization was primarily determined by the toothpaste's strontium‐ and fluorine‐releasing capacities rather than the fraction of S‐PRG filler. Using SR and microhardness analyses, Elkassas and Arafa (2014) demonstrated the superior remineralizing efficacy of fluoride varnish compared to fluoride toothpaste, which they attributed to the greater fluoride content of the varnish. However, toothpaste may yield better long‐term results because fluoride varnish is only intended for use over one year.
Kaga et al. (2014) reported that the buffering effect of S‐PRG filler inhibits enamel demineralization. An aqueous solution containing S‐PRG filler exhibited a rapid increase in pH at one day, a gradual increase over six days, and the lowest Ca ion concentration among remineralization solutions. Although human saliva can harden the enamel surface, calcifying solutions may have greater remineralizing potential due to their higher concentrations of calcium and phosphate (Reynolds 1997; Reynolds et al. 2003). Calcium phosphate precipitates on the enamel surface as an amorphous precursor that undergoes rapid transformation to apatite crystals (Shen et al. 2001). Lippert et al. (2004) observed no enamel hardening due to saliva.
A previous study reported higher SR values after remineralization with 70 wt% S‐PRG compared to untreated enamel. The improvement could have been due to an increasing number of filler particles on the enamel surface (Hahnel et al. 2014). Fluoride toothpaste can reportedly restore the surface of lesions (Gjorgievska et al. 2013; Mielczarek and Michalik 2014), indicating its potential utility in cases with an elevated risk of caries, such as orthodontic patients (Gjorgievska et al. 2013).
Due to the stability of the enamel composition and its poor ability to restore itself once its structure has been damaged, it is vital to create protocols that produce the least possible iatrogenesis. Among them, the use of different, less‐aggressive burs for removing residual cement accompanied by a remineralization protocol that can help reconstitute damaged enamel should be incorporated into any debonding protocol. It is important to minimise the structural damage previously discussed in all temporary bonding procedures and in fixed retentions.
Given that it is impossible to avoid changing the surface structure of the enamel even if the most appropriate and least invasive protocols are followed, the systematic use of post‐treatment remineralizing agents should be practically mandatory after treatment to remove residual cement. These parameters should remain a vital focus of study, as we have yet to find a non‐harmful method.
Al‐Moghrabi, D., Johal, A., O'Rourke, N. et al. (2018). Effects of fixed vs removable orthodontic retainers on stability and periodontal health: 4‐year follow‐up of a randomized controlled trial.
Am. J. Orthod. Dentofacial Orthop.
154 (2): 167–174.e1.
Anusavice, S.R. (2013). Materials and processes for cutting, finishing, and polishing. In:
Phillip's Science of Dental Materials
(ed. S.R. Anusavice), 231–253. Elsevier Ltd.
Bae, J.H., Yi, J., Kim, S. et al. (2014). Changes in the cutting efficiency of different types of dental diamond rotary instrument with repeated cuts and disinfection.
J. Prosthet. Dent.
111 (1): 64–70.
Ben‐Hanan, U., Judes, H., and Regev, M. (2008). Comparative study of three different types of dental diamond burs.
Tribol. Mater. Surf. Interfaces
2 (2): 77–83.
Bitter, N. (1998). A scanning electron microscope study of the long‐term effect of bleaching agents on the enamel surface in vivo.
Gen. Dent.
46 (1): 84–88.
Bosco, E., Iancu Potrubacz, M., Arrizza, L. et al. (2020). Enamel preservation during composite removal after orthodontic debonding comparing hydroabrasion with rotary instruments.
Dent. Mater. J.
39 (3): 367–374.
Bossù, M., Saccucci, M., Salucci, A. et al. (2019). Enamel remineralization and repair results of biomimetic hydroxyapatite toothpaste on deciduous teeth: an effective option to fluoride toothpaste.
J. Nanobiotechnol.
17 (1): 1–13.
Brosh, T., Strouthou, S., and Sarne, O. (2005). Effects of buccal versus lingual surfaces, enamel conditioning procedures and storage duration on brackets debonding characteristics.
J. Dent.
33: 99–105.
Choi, C., Driscoll, C.F., and Romberg, E. (2010). Comparison of cutting efficiencies between electric and air‐turbine dental handpieces.
J. Prosthet. Dent.
103 (2): 101–107.
Coceska, E., Gjorgievska, E., Coleman, N.J. et al. (2016). Enamel alteration following tooth bleaching and remineralization.
J. Microsc.
262 (3): 232–244.
Cochrane, N.J., Cai, F., Huq, N.L. et al. (2010). Critical review in oral biology & medicine: new approaches to enhanced remineralization of tooth enamel.
J. Dent. Res.
89 (11): 1187–1197.
David, V.A., Staley, R.N., Bigelow, H.F., and Jacobsen, J.R. (2002). Remnant amount and cleanup for 3 adhesives after debracketing.
Am. J. Orthod. Dentofacial Orthop.
121 (2): 291–296.
Di Cristofaro, R.G.R., Giner, L., and Mayoral, J.R. (2013). Comparative study of the cutting efficiency and working life of carbide burs.
J. Prosthodont.
22 (5): 391–396.
Eikenberg, S.L. (2001). Comparison of the cutting efficiencies of electric motor and air turbine dental handpieces.
Gen. Dent.
49 (2): 199–204.
Eisenburger, M., Addy, M., Hughes, J.A., and Shellis, R.P. (2001). Effect of time on the remineralization of enamel by synthetic saliva after citric acid erosion.
Caries Res.
35 (3): 211–215.
Eliades, T. (2019). Orthodontic applications of biomaterials.
J. Chem. Inf. Model.
53: 230.
Elias, K., Amis, A.A., and Setchell, D.J. (2003). The magnitude of cutting forces at high speed.
J. Prosthet. Dent.
89 (3): 286–291.
Elkassas, D. and Arafa, A. (2014). Remineralizing efficacy of different calcium‐phosphate and fluoride based delivery vehicles on artificial caries like enamel lesions.
J. Dent.
42 (4): 466–474.
Emir, F., Ayyildiz, S., and Sahin, C. (2018). What is the changing frequency of diamond burs?
J. Adv. Prosthodont.
10 (2): 93–100.
Ercoli, C., Rotella, M., Funkenbusch, P.D. et al. (2009). In vitro comparison of the cutting efficiency and temperature production of 10 different rotary cutting instruments. Part I: turbine.
J. Prosthet. Dent.
101 (4): 248–261.
Ercoli, C., Rotella, M., Funkenbusch, P.D. et al. (2009). In vitro comparison of the cutting efficiency and temperature production of ten different rotary cutting instruments. Part II: electric handpiece and comparison with turbine.
J. Prosthet. Dent.
101 (5): 319–331.