Concentrating on the natural science aspects of forensics, top international authors from renowned universities, institutes, and laboratories impart the latest information from the field. In doing so they provide the background needed to understand the state of the art in forensic science with a focus on biological, chemical, biochemical, and physical methods. The broad subject coverage includes spectroscopic analysis techniques in various wavelength regimes, gas chromatography, mass spectrometry, electrochemical detection approaches, and imaging techniques, as well as advanced biochemical, DNA-based identification methods. The result is a unique collection of hard-to-get data that is otherwise only found scattered throughout the literature.

Sie lesen das E-Book in den Legimi-Apps auf:

Android
iOS
von Legimi
zertifizierten E-Readern

Seitenzahl: 911

Veröffentlichungsjahr: 2016

Bewertungen
0,0
0
0
0
0
0
Mehr Informationen
Mehr Informationen
Legimi prüft nicht, ob Rezensionen von Nutzern stammen, die den betreffenden Titel tatsächlich gekauft oder gelesen/gehört haben. Wir entfernen aber gefälschte Rezensionen.



Table of Contents

Cover

Related Titles

Title Page

Copyright

List of Contributors

Preface

Chapter 1: Forensic Science – Chemistry, Physics, Biology, and Engineering – Introduction

References

Chapter 2: Forensic Applications of Vibrational Spectroscopy¥

2.1 Introduction

2.2 Trace Evidence

2.3 Ink Analysis

2.4 Forensic Biology and Anthropology

2.5 Gunshot Residue

2.6 Controlled Substances

2.7 Counterterrorism and Homeland Security

2.8 Emerging Technologies

2.9 Conclusions

Acknowledgments

References

Chapter 3: Applications of Internal Reflection Spectroscopy in Forensic Analysis

3.1 Introduction

3.2 Principles and Theory

3.3 Accessories for ATR

3.4 Forensic Applications of ATR

3.5 Conclusion

References

Chapter 4: Applications of Mass Spectrometry in Forensic Science: A Brief Introduction

4.1 Introduction

4.2 Mass Spectrometry

4.3 Applications of MS in Forensic Science

4.4 Conclusions

Acknowledgments

References

Chapter 5: An Introduction to Forensic Electrochemistry

5.1 Introduction

5.2 Electrochemical Methods

5.3 Voltammetric Methods

5.4 Electrochemical Methods in Forensic Science

5.5 Outlook for Forensic Electrochemistry

References

Chapter 6: Electrochemical Detection of Gunshot Residue for Forensic Analysis

6.1 Overview of Gunshot Residue Detection

6.2 Electrochemical Detection of Inorganic GSR

6.3 Electrochemical Detection of Organic GSR

6.4 Next Steps in GSR Analysis: Chemometric Data Treatment and Complementary Orthogonal Methods

6.5 Future Prospects for Electroanalytical Detection of GSR

References

Chapter 7: From Optical to Hyperspectral Imaging Techniques in Forensic Sciences

7.1 Added Value of Imaging Techniques in Forensic Sciences

7.2 Optical Examination in Forensic Sciences: A Step Before Hyperspectral Imaging

7.3 Hyperspectral Imaging: A Flourishing Technique in Forensic Sciences

7.4 Conclusions and Future Prospects of Hyperspectral Imaging in Forensic Sciences

References

Chapter 8: Biochemical Analysis of Biomarkers for Forensic Applications

8.1 Introduction

8.2 Biocatalytic Analysis of Biomarkers for Forensic Identification of Ethnicity Between Caucasian and African American

8.3 Biocatalytic Analysis of Biomarkers for Forensic Identification of Sex

8.4 Biocatalytic Assay to Determine Age of Blood Sample

8.5 Conclusions

Acknowledgment

References

Chapter 9: Processing Skeletal Samples for Forensic DNA Analysis

9.1 Introduction

9.2 Bone Evidence in Forensic Investigations

9.3 The Sources of DNA from Skeletal Remains

9.4 Postmortem Taphonomic Effects of Skeletal Remains

9.5 Contamination of Challenged Bone Specimens

9.6 Sample Preparation and Processing of Bone Evidence for Forensic DNA Analysis

References

Chapter 10: DNA Damage and Repair in Forensic Science

10.1 Mechanisms of DNA Damage

10.2 DNA Damage in Forensic Samples

10.3 DNA Repair Mechanisms

10.4 DNA Repair in Forensic Science

References

Chapter 11: Biosensors in Forensic Analysis

11.1 Introduction

11.2 The Use of Biosensors in Forensic Toxicological Analysis

11.4 Conclusions and Future Perspectives

Acknowledgments

References

Chapter 12: Recent Advances in Bloodstain Pattern Analysis

12.1 Introduction

References

Chapter 13: Detection of Cocaine on Paper Currency

13.1 Cocaine

13.2 Cocaine on Banknotes as Forensic Evidence

13.3 Methods of Analysis

Acknowledgments

References

Chapter 14: The Forensic Analysis of Glass Evidence: Past, Present, and Future

14.1 Glass as Forensic Evidence

14.2 A Brief History of Forensic Glass Analysis

14.3 Current Methods of Forensic Glass Analysis

14.4 Future Directions of Forensic Glass Analysis

14.5 Conclusions

Acknowledgment

References

Chapter 15: Forensic Examination of Trace Evidence

15.1 What Is Trace Evidence?

15.2 Major Types of Trace Evidence

15.3 Limitations and Significance of Trace Evidence

References

Chapter 16: Fingerprint Spoofing and Liveness Detection

16.1 Introduction

16.2 Fingerprint Spoofing

16.3 Liveness Detection

16.4 Summary

References

Chapter 17: Engineering as a Forensic Science

17.1 Introduction

17.2 Accident Reconstruction

17.3 Biomechanics of Injuries

17.4 Products Liability

17.5 Conclusion

References

Further Reading

Chapter 18: Unmanned Systems Technology Use by Law Enforcement

18.1 Evolution and Anatomy of Unmanned Systems

18.2 Law Enforcement Applications

18.3 Legal Issues

18.4 Unmanned Systems Deployment

References

Chapter 19: Forensic Science – Conclusions and Perspectives

Index

End User License Agreement

Pages

xiii

xiv

xv

xvi

xvii

xviii

xix

xxi

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

89

90

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

121

122

123

124

125

126

127

128

129

130

131

132

133

134

135

136

137

138

139

140

141

142

143

144

145

146

147

148

149

151

152

153

154

155

156

157

158

159

160

161

162

163

164

165

166

167

168

169

170

171

172

173

174

175

176

177

178

179

180

181

182

183

184

185

186

187

188

189

190

191

192

193

194

195

196

197

198

199

200

201

202

203

204

205

206

207

208

209

210

211

212

213

214

215

216

217

218

219

220

221

222

223

224

225

226

227

228

229

230

231

232

233

234

235

236

237

238

239

240

241

242

243

244

245

246

247

248

249

250

251

252

253

254

255

256

257

258

259

260

261

262

263

264

265

266

267

268

269

270

271

272

273

274

275

276

277

278

279

280

281

283

284

285

286

287

288

289

290

291

292

293

294

295

296

297

298

299

300

301

302

303

304

305

306

307

308

309

310

311

312

313

314

315

316

317

318

319

320

321

322

323

324

325

326

327

328

329

330

331

332

333

334

335

336

337

338

339

340

341

342

343

344

345

346

347

348

349

350

351

352

353

354

355

356

357

358

359

360

361

362

363

364

365

366

367

368

369

370

371

373

374

375

376

377

378

379

380

381

382

383

384

385

386

387

388

389

390

391

392

393

394

395

396

397

398

399

401

402

403

404

405

406

407

408

409

410

411

412

413

414

415

416

417

418

419

420

421

422

423

424

Guide

Cover

Table of Contents

Preface

Begin Reading

List of Illustrations

Chapter 1: Forensic Science – Chemistry, Physics, Biology, and Engineering – Introduction

Figure 1.1 Application of vibrational spectroscopy for forensic analysis.

Figure 1.2 Forensic electrochemistry – the electroanalytical sensing of gunshot residues.

Figure 1.3 Schematic delineating voltammetry of microparticles on a wearable

Forensic Finger.

(a) The

Forensic Finger

shows the three electrode surfaces screen-printed onto a flexible nitrile finger cot (bottom left inset), as well as a solid, conductive ionogel immobilized on a similar substrate (top right inset). (b) “Swipe” method of sampling to collect the target powder directly onto the electrode. (c) Completion of the electrochemical cell by joining the index finger with electrodes to the thumb coated with the solid ionogel electrolyte.

Chapter 2: Forensic Applications of Vibrational Spectroscopy¥

Figure 2.1 Influence of the shaking time on the forensic analysis of Raman spectra of spray paints. The Raman spectra of an acrylic red spray paint, containing the pigment Naphthol red, after 0–5 min of shaking are shown. The peak intensities decrease over time. The inset shows the maximum counts calculated for the peak at 1350 cm

−1

for the 15 replicates of each condition plotted using boxplots. The time point of 1 min shows a higher pigment concentration, as indicated by the highest boxplot values

Figure 2.2 Determining the best excitation wavelength for Raman spectroscopy for the forensic analysis of black and color inkjet-printed documents. Comparison of Raman spectra obtained for yellow Canon and Hewlett-Packard sample A (HP A) with 785 nm (red dotted line) and 458 nm (solid blue line) excitation wavelengths. Differences between the two spectra from the same ink are explained by a resonance effect.

Figure 2.3 Discrimination of human and animal blood traces via Raman spectroscopy. (a) Comparison of the preprocessed and averaged Raman spectra from all human (blue trace,

n

= 10) spectra and all animal (red trace,

n

= 100) spectra. (b) Cross-validated prediction scores for human class using the binary PLS-DA model. Red line represents the default classification threshold.

Figure 2.4 Brain tissue from rats analyzed by FTIR spectroscopy to estimate the time since death. The spectra shown were acquired from brain tissue 0–144 h after death. Peak intensities at several frequencies were used to create calibration curves and estimate the postmortem interval with 93–97% accuracy.

Figure 2.5 ATR-FTIR imaging for detection of microscopic GSR. (a) Visual image of the mapped tape substrate area. (b–d) ATR images of mapped area: each pixel represents one raw ATR-FTIR spectrum. The pixels are colored by intensities of transmitted light at (b) 1415 cm

−1

(chemical marker for IGSR), (c) 1646 cm

−1

(a chemical marker for OGSR), and (d) 1728 cm

−1

(chemical marker for tape substrate). (e) Color scale determining the intensities of detected chemical signal. Blue colored areas indicate strong absorption (low %

T

) by the analyte, at that specific frequency, while red colored areas indicate little to no absorption (high %

T

) by the analyte, at that specific frequency. (f) FTIR spectra of organic GSR, inorganic GSR, cotton fiber, and tape, showing the unique peaks used during mapping to identify samples.

Figure 2.6 Quantifying cocaine in binary mixtures with adulterants. Raman spectra collected from binary mixtures of cocaine with (a) sodium carbonate, (b) caffeine, (c) benzocaine, and (d) lidocaine, each prepared in several concentrations. Quantitative analysis of spectral data resulted in calibration curves that could be used to estimate the concentration of cocaine.

Figure 2.7 Discrimination of 14 explosive compounds using Raman spectroscopy and principal component analysis. Key below Figure shows color coding of the explosives. (a) Three-dimensional scatter plot of 14 different explosives scored on the first 3 components showing separation. (b) Closer view of the three-dimensional feature space showing the separation of 10 of the explosives.

Chapter 4: Applications of Mass Spectrometry in Forensic Science: A Brief Introduction

Figure 4.1 Mass spectrometer schematic (MALDI: Matrix Assisted Laser Desorption Ionization; ESI: Electrospray Ionization; TOF: time-of-flight).

Figure 4.2 (a) MALDI-TOF mass spectrometer principle. An ion source, a mass analyzer, and a detector are present on the instrument. At the detector, the mass spectrum is detected/recorded. The mass analyzer is TOF-type and can be used in the linear or reflective mode. (b) ESI-MS of peptides. An ESI-MS spectrometer. In ESI-MS, the sample is a liquid under high temperature and high electric current. The sample dehydrates and becomes protonated for positive ionization.

Figure 4.3 LC-MS/MS experiment of a peptide mixture. In each LC-MS/MS experiment, with elution of peptides from the HPLC gradually, the mass spectrometer analyzes the corresponding ions via MS survey (recorded in an MS spectrum). Ions with highest intensity (typically 1–8 ions; 2 ions in this example) are selected for MS/MS fragmentation, fragmented, and then recorded as MS/MS #1 and MS/MS #2.

Chapter 5: An Introduction to Forensic Electrochemistry

Figure 5.1 Typical screen-printed setup (a) that allows a route to point-of-care electrochemistry, which is a development of a typical laboratory-based setup in (b). WE, solid working electrode; CE, counter electrode; and RE, reference electrode.

Figure 5.2 Potential–time profile (a) for a voltammetric experiment and a current–potential plot (b), better known as a

voltammogram

.

Figure 5.3 Schematic diagram of the general process that occurs when testing for atropine in a Coca-Cola™ sample.

Figure 5.4 Cyclic square-wave voltammogram at the bare GCE for a mixture of trace metals and explosives constituents of GSR: 3 ppm Pb, 10 ppm Sb, 50 ppm NG, and 10 ppm DNT. Square wave parameters: Estep, 4 mV; amplitude, 25 mV; frequency, 8 Hz; and teq, 5 s; (reduction) Estart, 1.15 V; and Estop, −0.95 V; (oxidation) Estart, accum, −0.95 V; Estop, 1.15 V; and taccum, 120 s. Electrolyte, acetate buffer (pH = 4.5).

Figure 5.5 Illustrative concept of the voltammetric determination of Rohypnol™.

Figure 5.6 Electrolysis-etched fingerprint on a bullet.

Figure 5.7 Schematic diagram of the hybridization process. (a) Magnetic beads harness DNA fragments; (b) DNA hybridization occurs with the target DNA; (c) a second hybridization occurs, that tags quantum dots to the DNA; and (d) dissolution of the quantum dots and electrochemical detection take place via adsorptive stripping voltammetry.

Chapter 6: Electrochemical Detection of Gunshot Residue for Forensic Analysis

Figure 6.1 Voltammograms of a sample, blank, and standard: (1) gunshot residue showing Pb, Cu, and Sb; (2) blank electrolyte; and (3) blank electrolyte spiked with 30 ng Sb.

Figure 6.2 Adaptation for batch-injection analysis (BIA) with a commercial HMDE stand and cell for ASV GSR analysis. (A) Detailed photograph of the outlet section of the J-adaptor, fitted to the glass capillary. (B) Schematic of the electrochemical cell showing (a) mercury reservoir and valve, (b) micropipettor, (c) mercury electrode capillary, (d) hanging mercury drop, (e) J-adaptor outlet, (f) sealing pipettor tip, and (g) modified 100 µl pipette tip.

Figure 6.3 Multicommuted flow system for determining Pb(II) in GSR. S, sample; SS, standard solution of Pb(II); CS, carrier solution (10 mg l

−1

of Bi(III) in 0.1 mol l

−1

; acetate buffer solution, pH 4.5); D, detector; Sy, 10.0-ml syringe; W, waste; V1, V2, V3, three-way solenoid valves; and R1, R2, reaction coils (60 cm).

Figure 6.4 AbrSV of GSR samples from four subjects for three different conditions: in the laboratory, prior to any contact with GSR, named C1: first control; at the shooting lanes where others were discharging firearms, but without handling or discharging a firearm, named C2: second control; after discharging several rounds from the weapon (10 rounds for a Glock 40 and 8 rounds for a Sig Sauer 45) – F: Firing.

Figure 6.5 Use of “Forensic Fingers” for on-site analysis. Schematic delineates voltammetry of microparticles particles at a wearable Forensic Finger. (a) The Forensic Finger exhibiting the three-electrode surface screen-printed onto a flexible nitrile finger cot (bottom left inset), as well as a solid, conductive ionogel immobilized upon a similar substrate (top right inset). (b) “Swipe” method of sampling to collect the target powder directly onto the electrode. (c) Completion of the electrochemical cell by joining the index finger with electrodes to the thumb coated with the solid ionogel electrolyte.

Figure 6.6 Summary of cyclic voltammetric data for selected explosive compounds. Supporting electrolyte: 0.06 M monochloroacetic acid, 0.44 M sodium acetate, and 0.001 M EDTA, in 15% (v/v) l-propanol, pH 3.5. Scan rate, 300 mV s

−1

. Concentrations of explosives were between 100 and 200 µg ml

−1

.

Figure 6.7 Cyclic voltammograms of (a) diphenylamine and (b) centralite I, in acetonitrile. Sweep rate 100 mV s

−1

, concentration 0.2 mM.

Figure 6.8 Simultaneous organic/inorganic electroanalysis and cyclic square-wave voltammogram for a mixture of trace metals and explosive constituents of GSR: 2 ppm Zn, 2 ppm Pb, 20 ppm Sb, and 200 ppm DPA. Square-wave parameters:

E

step

, 4 mV; amplitude, 25 mV; frequency, 25 Hz; and

t

accum

, 120 s; (reduction)

E

start,accum

1.2 V and

E

stop

,−1.3 V; (oxidation)

E

start,accum

,−1.3 V;

E

stop

, 1.2 V; and

t

accum

, 120 s. Electrolyte, acetate buffer (pH = 4.5).

Figure 6.9 PCA score plots of current signals obtained with a gold microelectrode in a solution containing gunshot residues extracted from a 0.380 pistol with full jacketed (a) and normal ammunition (b), and from a 0.38 revolver with normal (c) and semi-jacketed ammunition (d).

Figure 6.10 (a) Example of the different cyclic square-wave stripping voltammetric signals obtained with “swiping” samples at a bare SPCE electrode. Score plot of the functions obtained after LDA analysis of the GSR samples according to (b) exposure level or (c) three-class response mode. Samples in (b) correspond to: N – no contact, S – secondary exposure, P – presence at discharge, L – load, F – fire, and W – wash. Samples in (c) correspond to free (N), witness (S and P), and involved (L, F, and W). See Section 2.3 for the electrochemical conditions.

Figure 6.11 Integration of the three orthogonal detection modes of SWV, SEM, and EDX. Comparison of (a) voltammetric, (b) SEM, and (c) EDX responses for samples from (A) a subject who has loaded a firearm and (B) a subject who has had no contact with GSR at SEM tape-modified electrode.

Chapter 7: From Optical to Hyperspectral Imaging Techniques in Forensic Sciences

Figure 7.1 Photographic image (a) and infrared image (b) of (A) a pair of black trousers stained with blood, (B) cloth samples with a name written on the inside of the collar, (C) burned document, (D) gunshot residues on a cloth sample, and (E) tire marks on a blue cloth sample.

Figure 7.2 Use of (a) normal light conditions and (b) luminescence conditions for the visual examination of three different gel pen inks.

Figure 7.3 Schematic representation of a hyperspectral system detailing the spectral camera setup.

Figure 7.4 Schematic representation of a three-dimensional hyperspectral data cube including the relationship between spectral and spatial dimensions and the resulting information obtained from a single pixel, a pixel line, and a single plane for one random wavelength.

Figure 7.5 Schematic representation of the three configurations for acquiring a hyperspectral image.

Figure 7.6 Steps to analyze a hyperspectral image.

Figure 7.7 Hyperspectral data unfolding process.

Figure 7.8 White-light photographs of all samples on the 12 different fabrics, and the results of the different hyperspectral imaging methods: band images, ratio images, PCA images, and SIMPLISMA images.

Figure 7.9 Spectra observed of a specific point identified as an explosive residue in the handprint NIR false color hyperspectral images: (a) ammonium nitrate residues; (b) dynamite residues; (c) single-base smokeless gunpowder residues; (d) double-base smokeless gunpowder residues; and (e) black powder residues.

Figure 7.10 Raman images of crossings using gel–liquid blue pen inks at different times separating the application of each ink line, where the horizontal line was applied first (green). The images were obtained using the MCR approach.

Chapter 8: Biochemical Analysis of Biomarkers for Forensic Applications

Figure 8.1 (a) Biocatalytic cascade for the two-enzyme CK/LDH assay. (b) Biocatalytic cascade for the one-enzyme CK assay. The following abbreviations are used in the scheme: CK (creatine kinase), PK (pyruvate kinase), LDH (lactate dehydrogenase), Crt (creatine), Crt-P (creatine phosphate), ATP (adenosine 5′-triphosphate), ADP (adenosine 5′-diphosphate), NAD

+

(β-nicotinamide adenine dinucleotide), NADH (β-nicotinamide adenine dinucleotide reduced), PEP (phospho(enol)pyruvic acid), Pyr (pyruvate), Lac (lactate), HK (hexokinase), G6PDH (glucose-6-phosphate dehydrogenase), NADP

+

(β-nicotinamide adenine dinucleotide phosphate), NADPH (β-nicotinamide adenine dinucleotide phosphate reduced), Glc (glucose), Glc6P (glucose-6-phosphate), and 6-PGluc (6-phosphate gluconic acid).

Figure 8.2 Absorbance (

λ

= 340 nm) corresponding to the consumption of NADH upon operation of the CK/LDH assay. The bottom (red) and top (blue) traces correspond to the application of samples with CK and LDH concentrations mimicking AA and CA groups, respectively. Bold solid curves show the median responses for both groups. Inset: box and whisker plot of Abs in AA and CA groups. The median value for each group is noted with the horizontal line in a box, the boxes represent the range of values from 25% to 7%, the ends of the whiskers represent the 5% and 95% of values, and the dots are the mean, maximum, and minimum values.

Figure 8.3 Absorbance (

λ

= 340 nm) corresponding to the production of NADPH upon operation of the CK assay. The bottom (blue) and top (red) traces correspond to the application of samples with CK concentrations mimicking CA and AA groups, respectively. Bold solid curves show the median responses for both groups. Inset: box and whisker plot of Abs in AA and CA groups. The median value for each group is noted with the horizontal line in a box, the boxes represent the range of values from 25% to 75%, the ends of the whiskers represent the 5% and 95% of values, and the dots are the mean, maximum, and minimum values.

Figure 8.4 Density histograms of the output signal (absorbance) obtained for (a) CA group and (b) AA group using the CK/LDH assay (see the biocatalytic cascade shown in Figure 8.1a). The histograms were derived from the experimental data shown in Figure 8.2. Superimposed is the kernel density curve.

Figure 8.5 Density histograms of the output signal (absorbance) obtained for (a) CA group and (b) AA group using the CK assay (see the biocatalytic cascade shown in Figure 8.1b). The histograms were derived from the experimental data shown in Figure 8.3. Superimposed is the kernel density curve.

Figure 8.6 Absorbance changes (ΔAbs) obtained for the two-enzyme CK/LDH assay applied to the redissolved serum samples mimicking CA (circles b) and AA (squares a) groups after their drying and aging for different time intervals. Zero time interval corresponds to the analysis of the freshly prepared samples without drying. The data represent mean values of ΔAbs normalized to the maximum ΔAbs value characteristic of the fresh samples mimicking the AA group, and the error bars represent relative standard errors of ΔAbs measurements from five samples. Note that the samples were composed of mixed sera from different donors with added CK and LDH to mimic their concentration difference in the CA and AA groups.

Figure 8.7 Receiver operating characteristic (ROC) empirical (curve a) and smoothed (curve b) for the two-enzyme CK/LDH assay. Random choice is denoted by the diagonal line (line c). The highlighted point on the plot (curve a) corresponds to the best sensitivity–specificity pair (the best tradeoff between them) giving the most accurate cut-off point for discrimination between CA and AA serum samples. Note that samples were sera from individual donors with known ethnic origin.

Figure 8.8 Time-dependent absorbance changes (

λ

= 340 nm) obtained upon running the enzyme assays. (a) CK assay with the “female” CK concentration. (b) CK assay with the “male” CK concentration. (c) CK/ALT assay with the “female” CK and ALT concentrations. (d) CK/ALT assay with the “male” CK and ALT concentrations. Inset: Bar chart showing the absorbance changing after 10 min of the assay performance: (a) CK/ALT assay and (b) CK assay. “M” and “F” bars correspond to the “male” and “female” enzyme concentrations, respectively. The enzymatic assays were performed in a 50 mM glycylglycine buffer solution, pH 7.95.

Figure 8.9 (a) Biocatalytic cascade used for the CK/ALT assay where CK and ALT were applied jointly as two biomarkers. (b) Extension of the CK/ALT assay for the color production visible by a naked eye. The following abbreviations are used in the scheme: CK (creatine kinase), PK (pyruvate kinase), LDH (lactate dehydrogenase), ALT (alanine transaminase), Crt (creatine), Crt-P (creatine phosphate), ATP (adenosine triphosphate), ADP (adenosine diphosphate), NAD

+

(ß-nicotinamide adenine dinucleotide), NADH (ß-nicotinamide adenine dinucleotide reduced), PEP (phospho(enol)pyruvic acid), Pyr (pyruvate), Lac (lactate), KTG (α-ketoglutaric acid), NBT (nitroblue tetrazolium), PMS (phenazine methosulfate).

Figure 8.10 Time-dependent absorbance changes (

λ

= 340 nm) obtained upon running the CK/ALT assay in human serum (50% v/v) solutions with (F) the “female” CK and ALT concentrations and (M) the “male” CK and ALT concentrations. Inset: The bar chart showing the absorbance changing after 10 min of the assay performance. “M” and “F” bars correspond to the “male” and “female” enzyme concentrations, respectively.

Figure 8.11 Bar chart showing absorbance changes (

λ

= 340 nm) obtained upon performing CK/ALT assay for 10 min on serum samples spiked with “male” (a) and “female” (b) CK and ALT concentrations and then after their drying, aging for different time intervals, and redissolving for the enzyme assay. Note that “0 h” experiment corresponds to the analysis of freshly prepared samples without drying/aging.

Figure 8.12 Time-dependent absorbance changes (

λ

= 580 nm) obtained upon performing chemical reaction of NBT and the residual NADH following the CK/ALT assay performed for 10 min for the serum (50% v/v) solutions spiked with “male” (M) and “female” (F) concentrations of CK and ALT. Inset: Photos of cuvettes with colored solutions obtained for the “male” and “female” samples after CK/ALT assay extended with the NBT reaction (note that the samples in this experiment were prepared in buffer solutions). Blue color in the left cuvette corresponds to the “female” sample.

Figure 8.13 Change in absorbance (

λ

= 340 nm) corresponding to the consumption of NADH upon operation of the CK-biocatalyzed reaction. The traces correspond to samples (

n

= 3) that mimic bloodstains, incubated at 40 °C from 0 to 120 h. Inset: Bar chart representing the change in absorbance at

λ

= 340 nm, after 30 min of assay completion.

Figure 8.14 Change in absorbance (

λ

= 340 nm) corresponding to the consumption of NADH upon operation of the ALT-biocatalyzed reaction. The traces correspond to samples (

n

= 3) that mimic bloodstains, incubated at 40 °C from 0 to 120 h. Inset: Bar chart representing the change in absorbance at

λ

= 340 nm, after 30 min of assay completion.

Figure 8.15 Change in absorbance (

λ

= 340 nm) corresponding to the consumption of NADH upon operation of the CK/ALT-biocatalyzed reactions operating in parallel. The traces correspond to samples (

n

= 3) that mimic bloodstains, incubated at 40 °C from 0 to 120 h. Inset: Bar chart representing the change in absorbance at

λ

= 340 nm, after 30 min of assay completion.

Figure 8.16 Absorbance change at

λ

= 340 nm, corresponding to the consumption of NADH after the analysis of the two different biocatalytic pathways (in the presence of CK or ALT) as well as the entire biocatalytic assay in the presence of both enzymes (CK and ALT). Time zero corresponds to the analysis of the freshly prepared samples without drying. The rest of the samples were resuspended in water after they underwent aging at 40 °C.

Figure 8.17 Absorbance change at

λ

= 340 nm, corresponding to the consumption of NADH after the analysis of the samples by the CK/ALT biocatalytic assay. Samples (

n

= 3) were resuspended after undergoing the aging process under different temperatures: 40, 25, and 18 °C, up to 120 h. Time zero corresponds to the freshly prepared samples without drying.

Chapter 9: Processing Skeletal Samples for Forensic DNA Analysis

Figure 9.1 Section of the FDNY (Fire Department of New York City) memorial wall. Memorial, at FDNY Engine Co. 10 in the Liberty Street of New York, to the Fallen Firefighters of 9/11, by Rambusch Studios.

Figure 9.2 Diagram of a long bone. A long bone, such as an arm and a leg bone, consists of an outer cylinder of cortical bone surrounding a marrow cavity. Each end of a long bone is called an

epiphysis

, which is composed largely of cancellous bone. Flat bones have variable structures; for example, the skull consists mainly of cortical bone, whereas the spine consists mainly of cancellous bone.

Figure 9.3 (a) Cross-sectional view of cortical bone. The functional unit of cortical bones is a cylindrical structure known as

osteon

(circled). Haversian canals are shown in the center of the osteon. (b) Detailed view of an osteon. Osteocytes (arrows) are shown within osteons.

Figure 9.4 A bone fragment. Cortical and cancellous bones are shown. In Volkmann's and Haversian canals, blood vessels can be found.

Figure 9.5 Human burial rib bone fragments.

Figure 9.6 Tools for cutting bone samples. Osteotomes (a), a mallet (a) and a rotary device (b; Dremel, Racine, WI).

Figure 9.7 Effect of trypsin treatment on STR (short tandem repeat) profiles. STR profiles were obtained with the AmpFℓSTR® MiniFiler™ amplification kit. Overall, the allele calls of the trypsin method were similar to those of the sanding method. The electropherograms of (a) a sanded and (b) a trypsin-treated sample. (Reproduced from Li [3], with permission of Taylor & Francis Group.)

Chapter 10: DNA Damage and Repair in Forensic Science

Figure 10.1 Primary structure of DNA that can be damaged in a number of ways.

Figure 10.2 UV spectrum.

Figure 10.3 UV photoproducts. (a) Structure of a CPD, formed by the saturation of the 5,6 double bonds of adjacent pyrimidines and the formation of a cyclobutyl ring. (b) (6–4) photoproduct formed between adjacent pyrimidines when the C4 hydroxyl or amino group of the 3′ base is transferred to the C6 position of the 5′ base, forming a C6–C4 ∅ bond.

Figure 10.4 8-Oxoguanine. This hallmark of oxidative damage is a miscoding lesion, pairing with adenine instead of cytosine.

Figure 10.5 STR profiles generated from bloodstains exposed to UVC. (a) A full nine-locus profile (Profiler, Applied Biosystems) could be amplified after exposure for up to 8 h (∼50 J cm

−2

min

−1

) and (b) only a partial nine-locus profile could be amplified after 12 h UVC (∼75 J cm

−2

min

−1

).

Figure 10.6 DNA in physiological stains: strand breaks. The decrease in molecular weight is proportional to the increase in strand breaks. (a) UVA-irradiated DNA on an alkaline agarose gel to visualize single strand breaks. (b) UVB irradiated DNA on an alkaline agarose gel. (c) UVA-irradiated DNA on a native agarose gel to visualize double strand breaks. (d) UVB-irradiated DNA on a native agarose gel. Lengths of UV irradiation relative to natural sunlight exposure in a Washington, DC, in July at noon are listed above each lane, and the sizes of the molecular weight marker

λ

HindIII are shown in (a).

Figure 10.7 DNA in physiological stains: environmental exposure. DNA was digested with lesion-specific endonucleases, resulting in single strand gaps at the sites of damaged bases. The decrease in molecular weight was proportional to the increase in damage. T4 pyrimidine dimer glycosylase (T4PDG) removes CPDs, and formamidopyrimidine dimer DNA-glycosylase (FPG) excises oxidative lesions. (a) Bloodstains were exposed to a subtropical (Florida, USA) climate in the summertime. There was no significant difference in the “plus enzyme” and “no enzyme” treated samples, indicating that UV photoproducts were not predominant lesions. Bloodstains exposed to a continental climate in the summertime (Nebraska, USA) showed the formation of (b) CPDs and (c) oxidative lesions after 3 days outdoors. (Reproduced from Hall

et al.

[36], with permission of Springer.)

Figure 10.8 Base excision repair pathway. A modified base is detected by DNA glycosylase as distortions in the helical structure. The base is removed, and subsequent endonuclease activity generates an AP site. The gap is filled in by a repair-proficient polymerase and the nick is sealed by a DNA ligase.

Figure 10.9 SSBR of UV-damaged DNA. DNA damaged with UVC light was incubated with components of the SSBR pathway. (a) Combined actions of endonuclease IV, Polymerase β, and DNA ligase resulted in a nine-locus DNA profile (PowerPlex 1.2). (b) Endonuclease and DNA ligase alone did not have a similar effect. (Reproduced from Hall and Ballantyne [35], with permission of Springer.)

Chapter 11: Biosensors in Forensic Analysis

Figure 11.1 Fundamentals of the bacterial reporter cell used for the electrochemical determination of arsenite. (a) Synthesis of the arsR repressor protein from the arsR gene under control of the ars promoter (Pars). (b) Binding of arsR to DNA. (c) Losing of arsR affinity for DNA binding sites in the presence of As(V) and increasing of the arsR and lacZ genes transcription, leading to β-Gal formation. (d) Diffusion of PAPG through the cell membrane and cleaving by β-Gal to form PAP detected electrochemically outside the cell.

Figure 11.2 Real image and schematic diagrams displaying the biodevice, the enzyme reactions, and the response to alcohol at the graphite–Teflon–AOx–HRP–ferrocene composite electrode.

Figure 11.3 (a) Aptasensor for cocaine determination, and (b) schematicoutline of the principle for cocaineelectrochemical aptasensor.

Figure 11.4 Configurations of SPR biosensors for the determination of testosterone: (a) Schematic of the SPR immunosensor assay binding process with nanogold label; (b) Scheme of SPR sensor setup with the PS – functionalized sensor chip.

Figure 11.5 Determination of

E. coli

O157:H7. (a) Capture onto MBs-pECAb followed by labeling with AuNPs/sECAb. (b) Detection of labeled

E. coli

O157:H7 through hydrogen evolution reaction at −1.0 V and chronoamperograms for 0 (top) to 10

5

(bottom) cfu ml

−1

. (c) Cyclic voltammograms in 1 M HCl for 0 (1) and 10

5

(2) cfu ml

−1

. (d) scanning electron microscopy (SEM) for heat-killed

E. coli

O157:H7 (A) and MBs-pECAb before (B) and after (C) incubation with 10

5

cfu ml

−1

E. coli

O157:H7 (bacteria pointed by white arrows).

Figure 11.6 Scheme of the protocol developed for the preparation of an electrochemical immunosensor for the determination of TNT. (1) Fabrication of an AET-SAM onto gold nanoparticles-modified GCE and covalent immobilization of PAMAM. (2) Covalent immobilization of TMB-OVA conjugate followed by sample loading and immobilization of anti-TNT antibody. (3) Immobilization of HRP-Ab.

Figure 11.7 Schematic diagram of the magnetosensing assay for DNA sequence-specific detection and quantification of

V. cholera

. (a) aPCR mix. (b) Hybridization reagent. (c) Tagging reagent. Steps: (1) Preparation of DNA sample followed by aPCR amplification of target ssDNA. (2) Hybridization. (3) Tagging of hybridization events. (4) DPASV detection.

Chapter 12: Recent Advances in Bloodstain Pattern Analysis

Figure 12.1 Viscosity measurements at different PCVs (15–75%) determined at two temperatures: room temperature (25 °C) and body temperature (37 °C).

Figure 12.2 Close-up of equine blood magnified by 2.5 × 0.07 using a Leica microscope, showing particle build-up on the edge of the blood drop.

Figure 12.3 Images depicting the drying of human blood at room temperature, acquired using a 2.5 × 0.07 magnification Leica microscope. (a) 15% PCV and (b) 75% PCV.

Figure 12.4 Bloodstain displaying visible spines on the periphery of the stain.

Figure 12.5 Typical boiling curve highlighting the boiling regimes for water. (a) Natural convection (around room temperature). (b) Nucleation boiling regime. (c) Transition boiling regime. (d) Film boiling regime.

Figure 12.6 Typical boiling curve highlighting the boiling regimes for blood. (a) Natural convection (around room temperature). (b) Nucleation boiling regime. (c) Transition boiling regime. (d) Film boiling regime.

Chapter 13: Detection of Cocaine on Paper Currency

Figure 13.1 Chemical structure of cocaine.

Figure 13.2 SEM image of cocaine crystals in the interstices between the fibers of a banknote.

Figure 13.3 Schematic representation of the cEIA for the detection of cocaine in extracts taken from banknotes.

Figure 13.4 Schematic representation of the in-gel immunodetection method for localization of cocaine on banknotes.

Chapter 14: The Forensic Analysis of Glass Evidence: Past, Present, and Future

Figure 14.1 Photograph of Wallner lines on the fractured edge of glass.

Figure 14.2 Photomicrograph of hackle marks on the fractured edge of glass.

Figure 14.3 (a–c) First three pages of the brochure for the original GRIM instrument from 1982.

Figure 14.4 Modern GRIM instrument.

Figure 14.5 Schematic of a LA-ICP-MS instrument.

Figure 14.6 Schematic of a LIBS instrument.

Figure 14.7 LIBS spectrum of glass.

Figure 14.8 LIBS spectra of three different types of glass (NIST SRM 621 Soda Lime, Pyrex, and NIST 1411 Borosilicate) showing the ability of LIBS for glass classification.

Figure 14.9 Schematic of a tandem-LA-LIBS instrument.

Figure 14.10 Transmission curves for double-pane architectural windows from Cardinal Corp. The top curve is the spectra for clear glass (2pClear) and shows greater transmission of UV and IR light as compared to original low-E glass (2pE180) and newer low-E glasses with increased spectral selectivity (2pE272, 2pE366, and 2pE340).

Figure 14.11 SiO

4

tetrahedral structures in crystalline and glassy silicates [144, 145]. The white circles represent silicon, and the black circles represent oxygen. A fourth oxygen would be located above or below each of the silicon atoms in the three-dimensional structure.

Figure 14.12 Photomicrographs of a glass sample in Nujol at 360× magnification using the diamond ATR objective, varied by increasing the contact pressure. (a) After initial contact. (b) After some contact. (c) After being crushed but not scattered. The length of the black bar measures 50 µm. (d) Mid-IR spectra of the glass shown in photomicrographs (a)–(c). As the contact pressure is increased, the glass peaks increase and the presence of the oil becomes insignificant.

Chapter 15: Forensic Examination of Trace Evidence

Figure 15.1 Linkages that can be established by the use of trace evidence.

Figure 15.2 Basic structure of a hair.

Figure 15.3 Human head hairs from the same individual collected at the same time. The variation in hairs is clearly seen.

Figure 15.4 Typical layers found in an OEM (original equipment manufacturer) paint system.

Figure 15.5 Automotive paint chip with 13 layers, showing internal clear layers, which appear as white in the photograph.

Figure 15.6 Physical match between several piece of automotive window glass.

Figure 15.7 Mud on a pickaxe used to dig a shallow grave. This mud was subsequently shown to have come from the bottom of the grave.

Figure 15.8 Generic layers of duct tape, showing all possible layers, although in reality not all may be present or detectable.

Figure 15.9 Bubbles from the manufacturing process located in duct tape adhesive.

Figure 15.10 Automotive headlight filaments showing (a) undamaged filament and (b) a distorted filament indicative of hot shock.

Figure 15.11 Physical match of a piece of automotive paint seized from the scene of a fatal accident to the body of the suspect vehicle.

Chapter 16: Fingerprint Spoofing and Liveness Detection

Figure 16.1 (a) Fingerprint mold made of dental material. (b) Finger fakes made of silicon. (c) Fingerprint mold made of etched PCB and the resultant fake.

Figure 16.2 (a) Fingerprint fake. (b) Fake overlaid on real finger. (c) Resulting imaged fake fingerprint.

List of Tables

Chapter 2: Forensic Applications of Vibrational Spectroscopy¥

Table 2.1 Most relevant ASTM and SWGMAT standards for various types of trace evidence [22–34]

Chapter 4: Applications of Mass Spectrometry in Forensic Science: A Brief Introduction

Table 4.1 Recent applications of mass spectroscopy in forensic science

Chapter 6: Electrochemical Detection of Gunshot Residue for Forensic Analysis

Table 6.1 Inorganic and organic compounds that may contribute to gunshot residue

Table 6.2 Summary of experimental conditions and target GSR analytes in the literature reviewed

Chapter 11: Biosensors in Forensic Analysis

Table 11.1 Biosensors employed for the determination of arsenic and cyanide

Table 11.2 Biosensors employed for the determination of illicit drugs

Table 11.3 Biosensors employed for the determination of toxins

Table 11.4 Biosensors employed for the determination of microorganisms

Table 11.5 Biosensors employed for the determination of chemical weapons

Table 11.6 Biosensors employed for the determination of explosives

Table 11.7 Biosensors employed for the determination of biological weapons

Chapter 12: Recent Advances in Bloodstain Pattern Analysis

Table 12.1 Reference Table depicting dry weight constants

W

c

PCV

derived for a range of PCVs

Chapter 13: Detection of Cocaine on Paper Currency

Table 13.1 Summary of the quantities of cocaine detected on banknotes of different currencies, and the analytical methods applied in each study

Table 13.2 Summary of recently reported analytical methods for the detection of cocaine on banknotes

Chapter 17: Engineering as a Forensic Science

Table 17.1 AIS severity code

Table 17.2 Safety hierarchy

Related Titles

Siegel, Jay S.

Forensic Chemistry

Fundamentals and Applications Series: Forensic Science in Focus (Volume 1)

2015

ISBN: 978-1-118-89772-0

 

Madea, B. (ed.)

Handbook of Forensic Medicine

2014

Print ISBN: 978-0-470-97999-0

Also available in electronic formats

 

Katz, E. (ed.)

Biomolecular Information Processing

From Logic Systems to Smart Sensors and Actuators

2012

Print ISBN: 978-3-527-33228-1

Also available in electronic formats

 

Katz, Evgeny (ed.)

Molecular and Supramolecular Information Processing

From Molecular Switches to Logic Systems

2012

Print ISBN: 978-3-527-33195-6

Also available in electronic formats

 

Katz, E. (ed.)

Information Processing

2 Volume Set (comprising 978-3-527-33228-1 and 978-3-527-33195-6)

2012

Print ISBN: 978-3-527-33245-8

Also available in electronic formats

 

Edited byEvgeny Katz and Jan Halámek

 

Forensic Science

A Multidisciplinary Approach

 

 

 

Editors

Dr. Evgeny Katz

Clarkson University

Department of Chemistry

Clarkson Avenue 8

NY

United States

 

Dr. Jan Halámek

University of Albany, SUNY

Department of Chemistry

1400 Washington Ave.

NY

United States

 

Cover credits

Media Manager 13230959 LongHa/ iStockphoto

Media Manager 150502642 Brandon Laufenberg / Getty Images

Getty 511741321 anayianova/ Getty Images

All books published by Wiley-VCH are carefully produced. Nevertheless, authors, editors, and publisher do not warrant the information contained in these books, including this book, to be free of errors. Readers are advised to keep in mind that statements, data, illustrations, procedural details or other items may inadvertently be inaccurate.

 

Library of Congress Card No.: applied for

 

British Library Cataloguing-in-Publication Data

A catalogue record for this book is available from the British Library.

 

Bibliographic information published by the Deutsche Nationalbibliothek

The Deutsche Nationalbibliothek lists this publication in the Deutsche Nationalbibliografie; detailed bibliographic data are available on the Internet at <http://dnb.d-nb.de>.

 

© 2016 Wiley-VCH Verlag GmbH & Co. KGaA,

Boschstr. 12, 69469 Weinheim, Germany

 

All rights reserved (including those of translation into other languages). No part of this book may be reproduced in any form – by photoprinting, microfilm, or any other means – nor transmitted or translated into a machine language without written permission from the publishers. Registered names, trademarks, etc. used in this book, even when not specifically marked as such, are not to be considered unprotected by law.

Print ISBN: 978-3-527-33894-8

ePDF ISBN: 978-3-527-69352-8

ePub ISBN: 978-3-527-69354-2

Mobi ISBN: 978-3-527-69355-9

oBook ISBN: 978-3-527-69353-5

Cover Design Susanne Paulker, Weinheim, Germany

List of Contributors

Juliana Agudelo

University at Albany

State University of New York

Department of Chemistry

1400 Washington Avenue

Albany, NY 12222

USA

Lourdes Agüí

University Complutense of Madrid

Department of Analytical Chemistry

Faculty of Chemistry

Ciudad Universitaria s/n.

28040 Madrid

Spain

Roshanak Aslebagh

Biochemistry and Proteomics Group

Department of Chemistry and Biomolecular Science

8 Clarkson Avenue

Potsdam, NY 13699

USA

Saira Bakshi

Clarkson University

Department of Chemistry and Biomolecular Science

8 Clarkson Avenue

Potsdam, NY 13699-5810

USA

Jack Ballantyne

University of Central Florida Department of Chemistry

National Center for Forensic Science

12354 Research Parkway

Suite 225

Orlando, FL 32826

USA

Craig E. Banks

Manchester Metropolitan University

Division of Chemistry and Environmental Science

Faculty of Science and Engineering

Chester Street

Manchester M1 5GD

UK

Scott D. Batterman

Batterman Engineering, LLC

Consultants in Forensic Engineering, Accident Reconstruction and Biomechanics

1415 Route 70 East

Suite 307

Cherry Hill, NJ 08034

USA

Steven C. Batterman

University of Pennsylvania

Department of Bioengineering

School of Engineering and Applied Science

School of Medicine

Department of Orthopaedic Surgery

Philadelphia,

PA 19104

USA

 

and

 

Batterman Engineering, LLC

Consultants in Forensic Engineering, Accident Reconstruction and Biomechanics

1415 Route 70 East

Suite 307

Cherry Hill,

NJ 08034

USA

Justin Bueno

University at Albany

State University of New York

Department of Chemistry

1400 Washington Avenue

Albany, NY 12222

USA

Maíias Calcerrada

University of Alcalá

Department of Analytical Chemistry

Physical Chemistry and Chemical Engineering

Ctra. Madrid-Barcelona Km. 33.600,

28871 Alcalá de Henares

Madrid

Spain

Costel C. Darie

Biochemistry and Proteomics Group

Department of Chemistry and Biomolecular Science

8 Clarkson Avenue

Potsdam, NY 13699

USA

Maria Ángeles Fernández de la Ossa

University of Alcalá

Department of Analytical Chemistry

Physical Chemistry and Chemical Engineering & University Institute of Research in Police Sciences

Ctra. Madrid-Barcelona Km. 33.600

28871 Alcalá de Henares

Madrid

Spain

Kyle C. Doty

University at Albany

State University of New York

Department of Chemistry

1400 Washington Avenue

Albany, NY 12222

USA

Pooya Estifaee

Plasma Research Laboratory

Department of Chemical and Biomolecular Engineering

8 Clarkson Avenue

Potsdam, NY 13699

USA

Ashley Foster

University of Nebraska-Lincoln

Department of Entomology

103 Entomology Hall

Lincoln, NE 68583-0816

USA

Carmen García-Ruiz

University of Alcalá

Department of Analytical Chemistry

Physical Chemistry and Chemical Engineering & University Institute of Research in Police Sciences

Ctra. Madrid-Barcelona Km. 33.600,

28871 Alcalá de Henares

Madrid

Spain

Jan Halámek

University at Albany

State University of New York

Department of Chemistry

1400 Washington Avenue

Albany, NY 12222

USA

Lenka Halámková

University at Albany

State University of New York

Department of Chemistry

1400 Washington Avenue

Albany, NY 12222

USA

Ashley Hall

University of Illinois at Chicago

Department of Biopharmaceutical Sciences

833 S Wood St.

456A PHARM (MC 865)

Chicago, IL 60612

USA

Anthony Hallett

Unmanned Response, Inc.

119B Lion Lane

Beaver

PA 15009

USA

Crystal Huynh

University at Albany

State University of New York

Department of Chemistry

1400 Washington Avenue

Albany, NY 12222

USA

Peter Johnson

Clarkson University

Department of Electrical and Computer Engineering

2201 CAMP Annex

8 Clarkson Avenue

Potsdam, NY 13699-5730

USA

Brooke Weinger Kammrath

University of New Haven

Department of Forensic Science

300 Boston Post Road

West Haven, CT 06516

USA

Evgeny Katz

Clarkson University

Department of Chemistry and Biomolecular Science

8 Clarkson Avenue

Potsdam, NY 13699-5810

USA

Stacey Klempner

The City University of New York

John Jay College of Criminal Justice

Department of Sciences, Forensic Science Program

524 West 59th Street

New York, NY 10019

USA

Ali Koçak

The City University of New York

John Jay College of Criminal Justice

Department of Sciences

524 West 59th Street

New York, NY 10019

USA

Andrew C. Koutrakos

University of Verona

PhD program in Nanosciences and Advanced Technologies, Forensic Science

P.let. L.A. Scuro 10

37134 Verona

Italy

Bethany A. J. Larkin

Manchester Metropolitan University

Division of Chemistry and Environmental Science

Faculty of Science and Engineering

Manchester M1 5GD

UK

Igor K. Lednev

University at Albany

State University of New York

Department of Chemistry

1400 Washington Avenue

Albany, NY 12222

USA

Richard Li

The City University of New York

John Jay College of Criminal Justice

Department of Sciences, Forensic Science Program

524 West 59th Street

New York, NY 10019

USA

María Lopez-López

University of Alcalá

Department of Analytical Chemistry

Physical Chemistry and Chemical Engineering & University Institute of Research in Police Sciences

Ctra. Madrid-Barcelona Km. 33.600,

28871 Alcalá de Henares

Madrid

Spain

Virginia M. Maxwell

University of New Haven

Department of Forensic Science

300 Boston Post Road

West Haven, CT 06516

USA

Meghann E. McMahon

Wisconsin Department of Justice

Division of Law Enforcement Services

Milwaukee Crime Laboratory

Milwaukee, WI

USA

Claire K. Muro

University at Albany

State University of New York

Department of Chemistry

1400 Washington Avenue

Albany, NY 12222

USA

Aoife M. O'Mahony

University California San Diego (UCSD)

Department of NanoEngineering

Laboratory of Nanobioelectronics

Gilman Drive

La Jolla, CA 92093-0448

USA

JoséManuel Pingarrón

University Complutense of Madrid

Department of Analytical Chemistry

Faculty of Chemistry

Ciudad Universitaria s/n.

28040 Madrid

Spain

Edward P. Randviir

Manchester Metropolitan University

Division of Chemistry and Environmental Science

Faculty of Science and Engineering

Chester Street

Manchester, M1 5GD

UK

John A. Reffner

John Jay College of Criminal Justice

The City University of New York

Department of Sciences, Forensic Science Program

524 West 59th Street

New York, NY 10019

USA

David A. Russell

University of East Anglia

School of Chemistry

Norwich Research Park

NR4 7TJ Norwich

Norfolk

UK

Kelsha Sanchez

The City University of New York

John Jay College of Criminal Justice, Department of Sciences, Forensic Science Program

524 West 59th Street

New York, NY 10019

USA

Stephanie Schuckers

Clarkson University

Department of Electrical and Computer Engineering

2201 CAMP Annex

8 Clarkson Avenue

Potsdam, NY 13699-5730

USA

Lynn Sims

University of Nebraska-Lincoln, Department of Entomology

103 Entomology Hall

Lincoln, NE 68583-0816

USA

Jamie P. Smith

Manchester Metropolitan University

Division of Chemistry and Environmental Science

Faculty of Science and Engineering

Chester Street

Manchester, M1 5GD

UK

Selma Mededovic Thagard

Plasma Research Laboratory

Department of Chemical and Biomolecular Engineering

8 Clarkson Avenue

Potsdam

NY 13699

USA

Susan van der Heide

University of East Anglia

School of Chemistry

Norwich Research Park

NR4 7TJ Norwich

Norfolk

UK

Victor Weedn

George Washington University

Department of Forensic Sciences

Somers Hall L-12

2100 Foxhall Road N.W.

Washington, DC 20007

USA

Desiree Williams

The City University of New York

John Jay College of Criminal Justice

Department of Sciences, Forensic Science Program

524 West 59th Street

New York, NY 10019

USA

Paloma Yáñez-Sedeño

University Complutense of Madrid

Department of Analytical Chemistry

Faculty of Chemistry

Ciudad Universitaria s/n.

28040 Madrid

Spain

Preface

Forensic science is a multidisciplinary area applying scientific methods for the purposes of law. This book is a carefully assembled collection of chapters written by the most qualified experts in the areas of forensic chemistry, physics, biology, and engineering. The topics selected for this volume reflect personal interests of the editors and represent cohesive view on the related natural science approaches and their use for the purposes of law. The chapters included in the book overview the most important topics in these subareas of forensic science and provide perspectives of their developments. Since a single volume cannot accommodate all subareas of forensic science, some of them were not included in this book. Particularly, art forensics, computational forensics, forensic accounting, forensic anthropology, forensic archeology, forensic botany, forensic entomology, forensic geology, forensic linguistics, forensic psychiatry, and many other forensic subareas were not included in this volume, allowing in the future further extension of this forensic book in another volume.

The different topics addressed in this book will be of interest to the interdisciplinary community active in the areas of forensic science. It is hoped that the collection of the different chapters will be important and beneficial for practical forensic specialists, researchers, and students working in various areas related to forensic science. Furthermore, the book is aimed to attract young scientists and introduce them to the field while providing newcomers with an enormous collection of literature references. We, indeed, hope that the book will spark the imagination of scientists to further develop the topics.

Finally, the editors (E. Katz and J. Halámek) and publisher (Wiley-VCH) express their thanks to all the authors of the chapters, whose dedication and hard work made this book possible.

Evgeny KatzJan Halámek

Potsdam, NY, USA

Albany, NY, USA

September 2015

Chapter 1Forensic Science – Chemistry, Physics, Biology, and Engineering – Introduction

Evgeny Katz and Jan Halámek

The word “forensic” originates from the Latin word forensis, which means public, to the forum, or public discussion. A modern definition of “forensic” is relating to, used in, or suitable to a court of law [1]. Any science used for the purposes of the law is a forensic science. Forensic sciences [2–4] deal with the application of scientific knowledge to legal problems and they are vital tools for unearthing the truth in any legal proceeding. Forensic sciences, including forensic chemistry [5–8], forensic biology [9, 10], forensic anthropology [11], forensic medicine [12], forensic materials science [13, 14], forensic engineering [15], computational forensics [16], and so on, are broadly used to resolve civil disputes, to justly enforce criminal laws and government regulations, and to protect public health.

In some subareas of forensic science, for example, in forensic botany [17], simple observation of plant samples collected at the crime scene could be enough for arriving at important conclusions, while in other forensic methods, such as forensic chemistry, sophisticated instrumental analytical methods are required [18]. The most frequently encountered examples of forensic science applications are fingerprints [19] and DNA analyses [20], both aiming at the identification of crime victims or criminals. However, forensic science methods go much beyond these well-known applications and often include various physical and chemical analytical methods. Vibrational spectroscopy (based on IR absorption and Raman scattering) [21] (Figure 1.1), internal reflection spectroscopy [22], mass spectrometry [23], and electrochemistry [24, 25] (Figure 1.2) have been applied for forensic analyses of human or animal hair, fiber, paints and inks, and a variety of human body fluids, as well as for the detection of gunshot residues, controlled substances (e.g., illicit drugs), explosives, and other chemical and biological agents. Spectral analysis of objects found at the crime scene can be subjected to hyperspectral imaging (HSI) to obtain both spatial and spectral information from the sample [26]. This technique enables investigators to analyze the chemical composition of traces and simultaneously visualize their spatial distribution. HSI offers significant potential for the detection, visualization, identification, and age estimation of forensic traces, also allowing forensic analysis of document forgery [27].

Figure 1.1 Application of vibrational spectroscopy for forensic analysis.

(Reproduced from Muro et al. [21], with permission of American Chemical Society.)

Figure 1.2 Forensic electrochemistry – the electroanalytical sensing of gunshot residues.

A biochemistry-/molecular biology-based subarea of forensic analysis, called forensic serology, deals with the complex task of gathering information on the type of sample, age, origin, or sex from biological fluids (blood, saliva, etc.) found at a crime scene [28]. Analysis of various biomarkers in biofluids found on the crime spot can help in arriving at preliminary conclusions about the race, sex, age, and so on, of possible suspects [29]. DNA typing of criminal suspects or victims can be extended to the DNA analysis of human remains [30], as well as to the analysis of DNA damage and repair in forensic samples [31]. While in most forensic analytical applications the samples collected at the crime scene are sent to a specialized laboratory for sophisticated instrumental analysis, rapid on-site analysis of the recovered samples could be very beneficial for crime investigation; thus, simple biosensors are finding their place in forensic practice [32]. The sensing devices can be miniaturized and ultimately assembled as a wearable fingertip sensor (forensic finger, Figure 1.3), used, for example, for the rapid on-site voltammetric screening of gunshot residues and explosive surface residues [33].

Figure 1.3 Schematic delineating voltammetry of microparticles on a wearable Forensic Finger. (a) The Forensic Finger shows the three electrode surfaces screen-printed onto a flexible nitrile finger cot (bottom left inset), as well as a solid, conductive ionogel immobilized on a similar substrate (top right inset). (b) “Swipe” method of sampling to collect the target powder directly onto the electrode. (c) Completion of the electrochemical cell by joining the index finger with electrodes to the thumb coated with the solid ionogel electrolyte.

(Reproduced from Bandodkar et al. [33], Royal Society of Chemistry. Used under a Creative Commons Attribution 3.0 Unported Licence.)