116,99 €
Cytogenetic Laboratory Management Cytogenetic Laboratory Management Chromosomal, FISH and Microarray-Based Best Practices and Procedures Cytogenetic Laboratory Management: Chromosomal, FISH and Microarray-Based Best Practices and Procedures is a practical guide that describes how to develop and implement best practice processes and procedures in the genetic laboratory setting. The text first describes good laboratory practices, including quality management, design control of tests, and FDA guidelines for laboratory-developed tests, and preclinical validation study designs. The second focus of the book is on best practices for staffing and training, including cost of testing, staffing requirements, process improvement using Six Sigma techniques, training and competency guidelines, and complete training programs for cytogenetic and molecular genetic technologists. The third part of the text provides stepwise standard operating procedures for chromosomal, FISH and microarray-based tests, including preanalytic, analytic, and postanalytic steps in testing, which are divided into categories by specimen type and test type. All three sections of the book include example worksheets, procedures, and other illustrative examples that can be downloaded from the Wiley website to be used directly without having to develop prototypes in your laboratory. Providing a wealth of information on both laboratory management and molecular and cytogenetic testing, Cytogenetic Laboratory Management will be an essential tool for laboratorians worldwide in the field of laboratory testing and genetic testing in particular. This book gives the essentials of: * Developing and implementing good quality management programs in laboratories * Understanding design control of tests and preclinical validation studies and reports * FDA guidelines for laboratory-developed tests * Use of reagents, instruments, and equipment * Cost of testing assessment and process improvement using Six Sigma methodology * Staffing training and competency objectives * Complete training programs for molecular and cytogenetic technologists * Standard operating procedures for all components of chromosomal analysis, FISH, and microarray testing of different specimen types This volume is a companion to Cytogenetic Abnormalities: Chromosomal, FISH and Microarray-Based Clinical Reporting. The combined volumes give an expansive approach to performing, reporting, and interpreting cytogenetic laboratory testing and the necessary management practices, staff and testing requirements.
Sie lesen das E-Book in den Legimi-Apps auf:
Seitenzahl: 1279
Veröffentlichungsjahr: 2017
COVER
TITLE PAGE
DEDICATION
PREFACE
ACKNOWLEDGMENTS
ABOUT THE COMPANION WEBSITE
SECTION I: BEST PRACTICES FOR LABORATORY OPERATIONS
1 GUIDELINES FOR GOOD CLINICAL LABORATORY PRACTICE
1.1 PHYSICAL FACILITIES
1.2 SPECIMEN TRANSPORT AND MANAGEMENT
1.3 PERSONNEL SAFETY
1.4 LABORATORY INFORMATION SYSTEM (LIS)
1.5 QUALITY MANAGEMENT
1.6 ORGANIZATION AND PERSONNEL
1.7 LABORATORY EQUIPMENT
1.8 TESTING OPERATING PROCEDURES
1.9 SAFETY PLAN
1.10 BIOSAFETY PLAN
1.11 CHEMICAL HYGIENE PLAN
1.12 HEALTH INSURANCE PORTABILITY AND ACCOUNTABILITY ACT (HIPAA) INCIDENT PLAN
APPENDIX 1.A
APPENDIX 1.B
APPENDIX 1.C: INFORMATION ON HMIS AND NFPA LABELING SYSTEMS USED IN LABORATORIES
FURTHER READING
MORE RESOURCES
HIPAA REFERENCE
2 QUALITY MANAGEMENT
2.1 QC PROGRAM
2.2 INDIVIDUALIZED QC PLAN (IQCP)
2.3 STANDARDS FOR TEST RECORDS AND REPORTING
2.4 OVERVIEW OF GENERAL CULTURING ISSUES
2.5 QI PROGRAM
2.6 PROFICIENCY TESTING
2.7 INSPECTION PREPARATION
2.8 CALIBRATION VERIFICATION
FURTHER READING
3 DESIGN CONTROL OF TESTS AND FDA GUIDELINES FOR LABORATORY DEVELOPED TESTS (LDTs)
3.1 DESIGN CONTROL OF TESTS
3.2 FDA GUIDELINE SUMMARY FOR LDTS
FURTHER READING
4 PRECLINICAL VALIDATION STUDIES
4.1 VALIDATION PLANS AND PROTOCOLS
4.2 VALIDATION REPORTS
4.3 EXAMPLE VALIDATION PLAN AND REPORT—ANALYSIS OF FISH PROBES FOR CHROMOSOME 5 DELETION AND MONOSOMY
4.4 EXAMPLE VALIDATION PLAN AND REPORT FOR THE FDA-APPROVED VYSIS ALK FISH PROBE
REFERENCE
FURTHER READING
5 REAGENTS, INSTRUMENTS, AND EQUIPMENT
5.1 REAGENTS
5.2 INSTRUMENTS AND EQUIPMENT
5.3 IQ, OQ, AND PQ PROCEDURES
5.4 EXAMPLE EQUIPMENT PROCESS VALIDATION PROTOCOL
FURTHER READING
SECTION II: BEST PRACTICES FOR STAFFING AND TRAINING
6 COST OF TESTING AND STAFFING REQUIREMENTS
6.1 LABOR COSTS
6.2 TIME AND COST ASSESSMENT
6.3 STAFFING HIRING NEEDS
6.4 STAFF TASK REQUIREMENTS
FURTHER READING
7 PROCESS IMPROVEMENT: SIX SIGMA APPROACH TO LABORATORY IMPROVEMENT
7.1 INTRODUCTION
7.2 DMAIIC TOOLS
7.3 DEFINING THE PROJECT
7.4 MEASURING VARIABLES
7.5 ANALYZE DATA FOR THE PROJECT
7.6 INNOVATE AND IMPROVE THE PROJECT
7.7 CONTROLLING THE RESULTS OF THE PROJECT
APPENDIX 7.A RAW BASELINE DATA
APPENDIX 7.B RAW CONTROL DATA
FURTHER READING
8 STAFF TRAINING AND COMPETENCY FOR A CYTOGENETICS LABORATORY
8.1 TECHNICIAN (NONLICENSED/CERTIFIED LAB PERSONNEL) TRAINING AND COMPETENCY
8.2 TECHNOLOGIST (LICENSED/ASCP‐CERTIFIED) TRAINING AND COMPETENCY
8.3 GENERAL SUPERVISOR/MANAGER TRAINING AND COMPETENCY
8.4 CYTOGENETIC TECHNICAL SUPERVISOR/DIRECTOR TRAINING AND COMPETENCY
FURTHER READING
9 TRAINING PROGRAM FOR CYTOGENETIC AND FISH TECHNOLOGISTS
9.1 TRAINING PROGRAM OVERVIEW AND OBJECTIVES
9.2 PROGRAM CONTENT
9.3 PRACTICAL COMPONENT
9.4 LECTURES, QUIZZES, AND ASSIGNMENTS
9.5 TRAINEE COMPETENCY AND COMPLETION OF THE PROGRAM
9.6 TRAINEE HANDBOOK
9.7 LOGS, COMPETENCY FORMS, AND EVALUATION FORMS
FURTHER READING
10 TRAINING PROGRAM FOR MOLECULAR GENETIC TECHNOLOGISTS
10.1 TRAINING OVERVIEW AND OBJECTIVES
10.2 PROGRAM CONTENT
10.3 PRACTICAL COMPONENT
10.4 LECTURES, QUIZZES, AND ASSIGNMENTS
10.5 TRAINING COMPETENCY AND COMPLETION OF THE TRAINING PROGRAM
10.6 TRAINEE HANDBOOK
10.7 LOGS, COMPETENCY FORMS, AND EVALUATIONS FORMS
FURTHER READING
SECTION III: STANDARD OPERATING PROCEDURES
11 GENERAL SOP INFORMATION BY TEST AND PREANALYTIC PROCEDURES
11.1 DEFINITION OF AN SOP
11.2 EXAMPLE TEMPLATE FOR WRITING AN SOP
11.3 CAP AND ACMG GUIDELINES FOR WRITING SOPS
11.4 PREANALYTIC PROCEDURES: ACCESSIONING SPECIMENS FOR ALL SPECIMEN TYPES
FURTHER READING
12 ANALYTIC PROCEDURES: CHROMOSOME ANALYSIS
12.1 PERIPHERAL BLOOD AND PERCUTANEOUS UMBILICAL BLOOD SPECIMEN FOR CONSTITUTIONAL DISORDERS
12.2 AMNIOTIC FLUID SPECIMENS
12.3 CHORIONIC VILLUS SAMPLING
12.4 SOLID TISSUE SAMPLES: TISSUE BIOPSIES AND PRODUCTS OF CONCEPTION
12.5 BONE MARROW AND BLOOD FOR HEMATOLOGIC MALIGNANCIES
12.6 LYMPH NODES AND SOLID TUMORS
12.7 BREAKAGE SYNDROMES
APPENDIX 12.A CYTOGENETICS BLOOD CULTURE AND HARVEST WORKSHEET
APPENDIX 12.B DAILY HARVEST LOG
APPENDIX 12.C TEST SLIDE BANDING LOG
APPENDIX 12.D BATCH BANDING LOG
APPENDIX 12.E ANALYSIS SHEET
APPENDIX 12.F PRENATAL CULTURE AND HARVEST WORKSHEET
APPENDIX 12.G CULTURE FAILURE LOG
APPENDIX 12.H AMNIOTIC FLUID COUNT GUIDELINES—FOR NORMAL AND EXTENDED STUDIES
APPENDIX 12.I HEMATOLOGIC CULTURE LOG
APPENDIX 12.J SPECIMEN SETUP—HEMATOLOGIC MALIGNANCIES
APPENDIX 12.K SOLID TUMOR CULTURE WORKSHEET
FURTHER READING
13 ANALYTIC PROCEDURES: FLUORESCENCE
IN SITU
HYBRIDIZATION (FISH) ANALYSIS
13.1 GENERAL INFORMATION
13.2 CAP AND ACMG GUIDELINES FOR PERFORMING FISH ANALYSES
13.3 CELL SORTING FOR PLASMA CELL DISORDERS FOR FISH ANALYSIS
13.4 GENERAL PROCEDURE FOR DIRECT LABELING OF FISH PROBES
13.5 PRENATAL MULTICOLOR PROBES
13.6 TOTELVYSION™ MULTICOLOR DNA PROBE MIXTURES
13.7 MULTICOLOR: TELOMERE, CENTROMERE, AND PAINT PROBES (CYTOCELL)
13.8 MICROSCOPE ANALYSIS FOR METAPHASE SCORING
13.9 MICROSCOPE ANALYSIS FOR INTERPHASE SCORING
13.10 FORMALIN-FIXED PARAFFIN-EMBEDDED PROCEDURE FOR FISH ANALYSIS
13.11 HER2/ERBB2 FISH ANALYSIS
13.12 UROVYSION (VYSIS) BLADDER CANCER FISH ANALYSIS
APPENDIX 13.Aa CONSTITUTIONAL FISH PROBES
APPENDIX 13.Ab HEMATOLOGIC FISH ASSAYS
APPENDIX 13.B PROBE CHART: PANELS OF PROBES
APPENDIX 13.C FISH DIRECT HARVEST LOG
APPENDIX 13.D BATCH HYBRIDIZATION LOG
APPENDIX 13.E GENERAL FISH PROBE ANALYSIS SHEET
APPENDIX 13.F FISH PROBE ANALYSIS SHEET—AML PANEL
APPENDIX 13.G FISH PROBE ANALYSIS SHEET—MDS PANEL
APPENDIX 13.H FISH PROBE ANALYSIS SHEET—CLL PANEL
APPENDIX 13.I FISH PROBE ANALYSIS SHEET—NHL PANEL
APPENDIX 13.J FISH PROBE ANALYSIS SHEET—MM PANEL
APPENDIX 13.K FISH PROBE ANALYSIS SHEET—ALL PANEL
APPENDIX 13.L FISH ANALYSIS SHEET—BCR/ABL/ASS TRIPLE FUSION
APPENDIX 13.M HER2 ANALYSIS SHEET
APPENDIX 13.N UROVYSION ANALYSIS SHEET
FURTHER READING
14 ANALYTIC PROCEDURES: CHROMOSOMAL MICROARRAY ANALYSIS (CMA)
14.1 TEST PRINCIPLE
14.2 COMPARING CONVENTIONAL CHROMOSOME ANALYSIS, FISH ANALYSIS AND CHROMOSOMAL MICROARRAY ANALYSIS
14.3 INTERPRETATION
14.4 PROCEDURE OVERVIEW
FURTHER READING
15 POSTANALYTIC PROCEDURES
15.1 REVIEWING AND REPORTING CASES FOR CHROMOSOME ANALYSIS
15.2 REVIEWING AND REPORTING CASES FOR FISH ANALYSIS
15.3 REVIEWING AND REPORTING CASES FOR MICROARRAY ANALYSIS
15.4 PROCEDURE FOR AVOIDANCE AND DETECTION OF CLERICAL ERRORS POST REPORTING
15.5 SPECIMEN, MATERIAL AND RECORD RETENTION, AND SPECIMEN DISPOSAL
APPENDIX 15.A RECORD OF RESULTS CORRESPONDENCE LOG
FURTHER READING
GLOSSARY
REFERENCE
INDEX
END USER LICENSE AGREEMENT
Chapter 01
TABLE 1.C.1 Example of Hazardous Materials Identification System.
TABLE 1.C.2 Example NFPA table.
Chapter 02
TABLE 2.1 Quality improvement template—annual review.
TABLE 2.2 Annual review of QI program—example results.
TABLE 2.3 Example of common cancer probes used for clinical testing with different numbers of nuclei scored during validation for establishing cutoff values used for setting reference range limits.
TABLE 2.4 Cut off values for 200 interphase cells examined at 95 and 99% confidence intervals.
TABLE 2.5 Calibration verification of FISH probes for cancer probes.
Chapter 03
TABLE 3.1 Phase completion documentation.
Chapter 04
TABLE 4.1 One‐sided test for a binomial proportion to determine the number of metaphases or interphase cells required to provide a sufficient confidence limit or power
*
(95 or 99%) to detect mosaicism or chimerism at varying levels of analytical sensitivity using interphase FISH. (See Dewald et al. (1998).)
TABLE 4.2 Normal cutoffs at 95 and 99% confidence intervals.
TABLE 4.3 Common cancer probes with different numbers of nuclei scored during validation for establishing cutoff values.
TABLE 4.4 Raw data and results of 20 normal individuals and 5 individuals with abnormal results.
TABLE 4.5 Sensitivity data from the 20 normal individual analyses.
TABLE 4.6 Specificity data from the five normal individual analyses.
TABLE 4.7 Precision results—two copies of the chromosome 5.
TABLE 4.8 Precision results specimens—one copy of the 5q locus.
TABLE 4.9 Signal patterns with their cutoff values calculated.
TABLE 4.10 Summary data from the stability studies.
TABLE 4.11 Stability assay.
TABLE 4.12 Intra‐assay reproducibility.
TABLE 4.13 Interassay reproducibility.
TABLE 4.14 Classification of cells as positive or negative.
TABLE 4.15 Intraassay reproducibility results.
TABLE 4.16 Interassay reproducibility results.
TABLE 4.17 Stability assay results.
Chapter 05
TABLE 5.1 Example cytogenetics reagent verification log.
TABLE 5.2 Example FISH probe verification log.
TABLE 5.3 Microscope cleaning log.
TABLE 5.4 High and low temperature monitoring log—front side.
TABLE 5.5 ThermoBrite quality control log.
TABLE 5.6 Example of a general IQ form.
TABLE 5.7 Example of a general OQ form.
TABLE 5.8 Example of a general PQ form.
Chapter 06
TABLE 6.1 Direct labor costs.
TABLE 6.2 Indirect labor costs.
TABLE 6.3 Example direct time and cost assessment for two chromosome and two FISH tests.
TABLE 6.4 Example indirect cost per test (dollars per test).
TABLE 6.5 Example detailed time assessment for each cytogenetic study.
TABLE 6.6 Staffing needs.
TABLE 6.7 Example job grid with different lab staff and their respective assigned tasks.
Chapter 07
TABLE 7.1 DPMO values corresponding to various sigma levels.
TABLE 7.2 Asking the critical questions.
TABLE 7.3 ARMI members.
TABLE 7.4 Baseline data—summary.
TABLE 7.5 Sigma level calculations.
TABLE 7.6 XY matrix.
TABLE 7.7 Data stratification.
TABLE 7.8 FMEA.
TABLE 7.9 Control data—summary.
TABLE 7.10 Comparison of baseline and control data.
Chapter 08
TABLE 8.1 Technician/technologist training plan.
TABLE 8.2 Revisions or updates to training module.
TABLE 8.3 Training verification document.
TABLE 8.4 Training verification document (previously trained employees).
TABLE 8.5 General supervisor/manager competency assessment.
TABLE 8.6 Cytogenetics director/technical supervisor—competency assessment.
TABLE 8.7 Cytogenetics director/technical supervisor—competency verification checklist.
TABLE 8.8 Training update for procedure changes.
Chapter 09
TABLE 9.1 Training verification checklist.
TABLE 9.2 Training verification checklist.
TABLE 9.3 Training verification checklist.
TABLE 9.4 Training verification checklist.Module no.4 Cancer
TABLE 9.5 Training verification checklist.Module no.5 Molecular/FISH
TABLE 9.6 Training verification checklist.Module no.6a and b Microscopy and imaging
TABLE 9.7 Practical schedule.
TABLE 9.8 Student practical section evaluation.
TABLE 9.9 Case Documentation Log.
TABLE 9.10 Trainee module evaluation.
Chapter 10
TABLE 10.1 Practical training case documentation log.
TABLE 10.2 raining verification checklist.
TABLE 10.3 Trainee module evaluation.
TABLE 10.4 Summary of completion of the training program.
TABLE 10.5 Training time allocation: practical and lectures.
Chapter 11
TABLE 11.1 Cytogenetic test requirements.
Chapter 12
TABLE 12.1 Common synonyms and abbreviations for chromosome analysis.
TABLE 12.2 Clinical features and gene location of the chromosomal breakage syndromes.
Chapter 13
TABLE 13.1 Common synonyms and abbreviations for FISH testing.
TABLE 13.2 ToTelVysion hybridization probe areas.
TABLE 13.3 Optimal microscope and filter setup.
TABLE 13.4 Slide preparation for centromeres and telomeres.
TABLE 13.5 Slide preparation for paint probes.
Chapter 02
FIGURE 2.1 Bacterial contamination. Images showing an adherent cell culture contaminated with the bacteria
Escherichia coli
. The spaces between the adherent cells show tiny, shimmering granules under low power microscopy, but the individual bacteria are not easily distinguishable (a). Further magnification of the area enclosed by the black square resolves the individual
E. coli
cells (b), which are typically rod‐shaped and are about 2 µm long and 0.5 µm in diameter.
FIGURE 2.2 Yeast contamination. The arrows point to the ovid yeast particles.
Chapter 04
FIGURE 4.1 Results of slides that have been probed with the DNA LSI EGR1/D5S23, D5S721 FISH probe from Vysis will typically show two abnormal signal configurations.
FIGURE 4.2 Metaphase with inverted DAPI showing two normal chromosome 5 homologs with two red and two green signals (arrows). Interphase cells show both normal cells with 2R2G and abnormal cells with monosomy 5 showing 1R1G signals (arrows).
FIGURE 4.3 ALK enumeration signal guide (derived from manufacturer insert).
FIGURE 4.4 Negative and positive signal patterns.
Chapter 07
FIGURE 7.1 Six Sigma Black Belt/Green Belt project charter summary for increasing microscope productivity.
FIGURE 7.2 SIPOC.
FIGURE 7.3 Process map of steps involved in microscope analysis.
FIGURE 7.4 Data collection plan.
FIGURE 7.5 Histogram of baseline summary data.
FIGURE 7.6 Percent defectives per variable.
FIGURE 7.7 Fishbone diagram.
FIGURE 7.8 Process map with improvements.
FIGURE 7.9 Final process map.
FIGURE 7.10 (a) Histogram of the baseline data. (b) Histogram of the control data.
Chapter 12
FIGURE 12.1 Example process map of all the steps in hematologic chromosome analyses.
Chapter 14
FIGURE 14.1 Typical G‐band karyotype with trisomy 21 (47,XY,+21; arrow) detected by conventional chromosome analysis at a 500‐band level of resolution.
FIGURE 14.2 Fluorescence
in situ
hybridization showing two green control probes, indicating the pair of homologous chromosome 4’s. The missing red signal demonstrates the 4p16.3 microdeletion on one homologous chromosome 4 [(ish del(4)(p16.3p16.3)(WHSC1‐)], consistent with Wolf–Hirschhorn syndrome. Green, control probe; Red, 4p16.3 probe.
FIGURE 14.3 Black vertical lines represent oligonucleotide probes on a chromosome: 1 probe is placed approximately every 20–25 kb for the backbone coverage . Other clinically relevant regions, including telomeres, centromeres, microdeletions, and microduplications, and selected clinically relevant genes contain enhanced coverage . The blue bars represent the unique telomere (pter and qter) regions, and the yellow bars represent the unique pericentromeric (cen) regions that are targeted on the array.
FIGURE 14.4 CMA showing the relative ratio of patient DNA to control DNA which allows for the detection of gains and losses (copy number changes) at each probe locus. (a) Oligonucleotide probes that are complementary to specific regions of the genome are generally synthesized at unique positions on the array slide. Genomic DNA from the patient and a control are labeled independently with different fluorescent dyes, mixed together, and cohybridized to the microarray. Following competitive hybridization, the slides are scanned, and the intensities of the two fluorochromes are measured. The intensity data for each probe on the array are normalized and the relative ratio of the patient to the control DNA is plotted on a log
2
scale for each chromosome. (b) The log
2
ratio plots are analyzed to determine the relative gain or loss (red plot) of patient DNA relative to control DNA at the genomic location of each probe.
Cover
Table of Contents
Begin Reading
iii
iv
xi
xiii
xiv
xv
xvi
xvii
xviii
xix
1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
64
63
66
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
253
255
256
257
258
259
260
261
262
263
264
265
266
267
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
346
347
348
349
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
385
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
811
812
813
814
815
816
SUSAN MAHLER ZNEIMER
Adjunct Professor, Moorpark College, California, USACEO and Scientific Director, MOSYS Consulting, California, USA
Copyright © 2017 by John Wiley & Sons, Inc. All rights reserved
Published by John Wiley & Sons, Inc., Hoboken, New Jersey
Published simultaneously in Canada
No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, scanning, or otherwise, except as permitted under Section 107 or 108 of the 1976 United States Copyright Act, without either the prior written permission of the Publisher, or authorization through payment of the appropriate per‐copy fee to the Copyright Clearance Center, Inc., 222 Rosewood Drive, Danvers, MA 01923, (978) 750‐8400, fax (978) 750‐4470, or on the web at www.copyright.com. Requests to the Publisher for permission should be addressed to the Permissions Department, John Wiley & Sons, Inc., 111 River Street, Hoboken, NJ 07030, (201) 748‐6011, fax (201) 748‐6008, or online at http://www.wiley.com/go/permissions.
Limit of Liability/Disclaimer of Warranty: While the publisher and author have used their best efforts in preparing this book, they make no representations or warranties with respect to the accuracy or completeness of the contents of this book and specifically disclaim any implied warranties of merchantability or fitness for a particular purpose. No warranty may be created or extended by sales representatives or written sales materials. The advice and strategies contained herein may not be suitable for your situation. You should consult with a professional where appropriate. Neither the publisher nor author shall be liable for any loss of profit or any other commercial damages, including but not limited to special, incidental, consequential, or other damages.
For general information on our other products and services or for technical support, please contact our Customer Care Department within the United States at (800) 762‐2974, outside the United States at (317) 572‐3993 or fax (317) 572‐4002.
Wiley also publishes its books in a variety of electronic formats. Some content that appears in print may not be available in electronic formats. For more information about Wiley products, visit our web site at www.wiley.com.
Library of Congress Cataloging‐in‐Publication data applied for
ISBN: 9781119069744
Cover credit: © ttsz/Gettyimages
I dedicate this book to my daughters, Mira and Alana, who since they were born have changed my life forever and for the better. They have given me strength, inspired me to do great things, and have given me abounding love. I hope I have done the same for them.
Mira and Alana, I wish you both a life of good health, happiness, and profound significance. And may you strive for Tikkun Olam.
And to my dear friend and colleague, Lauren Jenkins, whom I have known for most of my life. Your time on this earth was much too short. I miss you with all my heart.
Lauren died on Rosh Hashanah 5776 (September 14, 2015).
For the last 25 years, I have been the director of different cytogenetic laboratories. Like most directors, I started out in academia for my American Board of Medical Genetics fellowship, but then moved on to various commercial laboratories for the next 20 years, and now currently to consulting for different genetic laboratories, both commercial and academic. After all these years, I realize that my daily work consists of two main tasks, signing out cytogenetic cases and managing the clinical laboratory. I wrote my first book, Cytogenetic Abnormalities, Chromosomal, FISH and Microarray‐Based Clinical Reporting, published by Wiley Publishers in 2014, to reflect all the information that I have learned in signing out cases throughout my career. In this book I want to focus on the other aspects of my laboratory duties, namely, laboratory management. Managing or directing a lab requires vastly different skills than what we learn as scientists who need to perform, review, and interpret cytogenetic laboratory results. As scientists, we generally receive little training in the field of management, let alone laboratory management. As geneticists, we rely on our scientific knowledge base and experience in genetic procedures to perform and sign out test results. We acquire those skills after years of working in the laboratory in graduate school and postdoctoral programs.
However, laboratory management uses other skills that we usually learn “on the job.” We learn that to be a good director or manager, we need to be good at interpersonal relations, organization, and time management. We learn to be supportive of the laboratory staff yet be good disciplinarians when performance is not acceptable. We learn to be innovative and strive to be as productive as possible. We learn to be conscious of interpreting patient results and performing genetic analyses with complete accuracy, yet to also be aware of the “bottom line” in order to be within a specific budget. It is a balancing act that we must perform daily and get right every time. Genetic results require 100% accuracy in diagnostic testing as well as being business savvy to be always within a budget; otherwise, our jobs may be in jeopardy.
For these reasons, I decided to write this book on laboratory management. I know what most lab directors and managers face with regards to “running a lab.” So I want to share as much as possible to make life easier for those just starting out, as well as for labs that can use ways to improve their laboratory processes to meet the demands of patient care and their institution’s requirements.
One of the most important things I have learned in management skills (from my father actually) is that as a director or manager of a laboratory or department, one does not manage people; instead, one manages a laboratory or department, and one guides or leads people. There are many different management styles for leaders or leadership. My style is to engage the staff in the processes and procedures of the laboratory and to provide the tools necessary to empower the staff to do their work correctly and efficiently and as independently as possible. I am often the most vocal cheerleader in the laboratory, supporting the staff as best I can in order to give them the assistance and encouragement they need to do their work well and simultaneously enjoy it. Happy employees are generally the most productive employees. By keeping good employees happy in their job, they also tend to have a greater sense of loyalty to their leaders and will support decisions made by the managers. Throughout the years, I have enjoyed great relationships with my present and past employees and companies by keeping a positive demeanor in the laboratory and knowing that I am part of the laboratory team, not above it.
After all these years, I am also aware of some of the possible mistakes that can be made. There is no room for sentimentality as a lab director or manager. Being too hard a leader can cause resentment or shutting down communication between staff and leader of the lab. However, being too soft a leader can be as difficult as being too hard on staff. Staff will certainly take advantage of a leader who is too sympathetic when given the chance. I also know that stress on the job often comes, not necessarily from the daily operations of the laboratory, but often from the demands placed on the directors from those who are higher in the organization hierarchy. It is so easy to feel that as the director of a genetics laboratory, we know best how to run the department, and no one knows better than we do about the testing we perform. However, that often creates conflict with those who place demands on us that differ from our own beliefs in how to direct the laboratory. So how do we resolve these conflicts? That is exactly what I have been analyzing during my years as a laboratory director.
I do know that being too vested in the decisions of the laboratory can be as detrimental as being too aloof when handling conflicting objectives, that is, what is imposed on us versus what we believe. Being so sure of oneself and one’s decisions can lead to arrogance and stubbornness, which often are not in the best interests of the laboratory, its processes, and staff. So this is truly a balancing act that either leaves one feeling elated when it works well or too stressed or “burned‐out” when it does not.
In this book, I am providing information on various topics in laboratory management for those of us who are continually trying to improve ourselves and our laboratories. This book has gray and boxed sections for CAP guidelines, and condensed ACMG guidelines, and other boxes for lists of information for easier reading.
The first section of the book focuses on best practices for laboratory operations, which contains chapters on quality and safety processes that are common in cytogenetic labs; reagent lists and an SOP on reagent verification for clinical use; quality control, quality assurance, and quality improvement SOP’s that are needed for College of American Pathologists (CAP) and Clinical Laboratory Improvement Act (CLIA) regulatory agencies; and ways to perform both internal and external proficiency tests, such as for CAP. This section also includes ways to prepare for a CAP inspection, to “pass with flying colors,” by giving tools on how to make an inspection go smoothly and provide the necessary information to inspectors. This section also discusses calibration verification and how it is used in a cytogenetics laboratory, especially on how it pertains to deriving FISH cutoffs for DNA probes and how to keep up to date with this process, since it is a CAP requirement.
More relevant information to laboratories regarding other aspects of laboratory management, including designing laboratory developed tests (LDTs), FDA guidelines for LDTs, and preclinical validation studies, is also provided in this section. We know in cytogenetic testing that we need to have all of our tests validated, with the exception of FDA‐approved tests, which only need the performance characteristics confirmed in the laboratory when tests are performed “on‐label.” Since most cytogenetic tests are not FDA approved or are FDA‐approved tests that are “off‐label,” these tests need proper validations performed before clinical use, with a validation plan and SOP and a validation report. Therefore, I have provided templates and example validation plans and reports that can be downloaded for laboratory use.
The second section of the book describes best practices for staffing and training employees in a cytogenetics laboratory. So much of what we do as directors are ensuring that staff are trained, competent, and efficient in their work. That requires a lot of dedication to the staff and a great deal of paperwork to document their performance in the laboratory. My goal here is to provide template benchmarks and documents, including spreadsheets that can be downloaded so that laboratories do not have to generate new forms for each item required, and to also provide the necessary steps for each test to prove training and competency of staff. I have also provided template “Training Programs” for cytogenetic and molecular genetic technologists (that comply with California standards—currently the most stringent of all the states in training and licensing technologists).
A chapter on Six Sigma for process improvement is also provided. Six Sigma is a sophisticated approach to improving processes, which applies well to cytogenetic laboratories. As a certified “green belt” in Six Sigma and Lean Processes, I give examples of how to improve processes in a business manner that organizations like to see for the purpose of being able to buy essential equipment, increase staffing where needed, and improve efficiency in a laboratory.
The third section of this book focuses on standard operating procedures. This is not an attempt to be comprehensive of all the possible procedures in every aspect of cytogenetic testing, since there are many other sources for this information. Rather, I am putting together common practices used in most laboratories, mainly to offer prototypes of each procedure as templates which can be used as is or with one’s own variations. These SOPs will help labs acquire procedures that can be “downloaded” into their laboratory, which can then be modified for one’s own use, rather than starting from scratch. As a result, a director’s job will be much easier by being able to use these SOPs in the correct format for regulatory purposes and to provide the necessary steps for each SOP that cytogenetic laboratories need. We most often focus our SOPs on each individual step of the process, but we also need to understand the format that is required and include the pre‐ and postanalytic steps of processes which may be overlooked. Also, many labs do not process all sample types or all the various tests that are available. In that case, when adding new tests, it is often hard to start writing a new SOP in the correct format from scratch. This is true especially for microarrays, where there is relatively little information on SOPs for this type of testing. I have not included a detailed microarray assay for this very reason. I have found no SOP to date that applies equally well for any laboratory since I believe there is too wide a variety of processes that can be used in this technology. Thus, there is no real standard SOP as yet to share with laboratories.
My goal is that when you read this book, it will be a handbook for you, and you will use it for practical purposes. I have provided many spreadsheets, forms, and SOP’s that can be downloaded, saving time in developing these documents on your own. I also hope that this book can give ideas on how to save time, use good time management and organization, help enhance management skills, and improve your laboratory processes. Please feel free to contact me if you have information you would like to share on this topic.
Sincerely,SUSAN MAHLER ZNEIMER, PH.D., FACMGGCEO, MOSYS [email protected]
I wish to thank those who have graciously read my manuscript for content and coherence. Special thanks go to Nancy Wold and Martin Chetlen for all their assistance and guidance throughout the duration of this product.
I would also like to thank the many cytogenetic directors and laboratory staff who have inspired me with their work and knowledge to write this book. All these people and their laboratories have provided me with invaluable information throughout my career.
My deep appreciation goes to the directors and staff of the following laboratories:
Alfigen (The Genetics Institute): Omar Alfi, Veronica Ward
Texas A&M University: James Womack
University of Texas Southwestern Medical Center: Nancy Schneider, Golder Wilson, Debra Cohen, Rene Payne
Genetrix: John Stone, Robert Wassman; Denise Main, Debra Giroux
Kaiser Permanente Laboratories: Lauren Jenkins, Mehdi Jamedhor, Britt Ravnan, John Mann, JoAnn Bergoffen, Lloyd Maxwell, Michael Tiffert, Angela Lim, and so many more
Quest Diagnostics/Smith‐Kline Beecham: JoAnn Kelly, Dwanna Stewart, James Ray, MervatAyad, and so many more
City of Hope: Joyce Murata‐Collins, Popsie Gaytan
CombiMatrix: Karine Hovanes
Genzyme: Bing Huang, Maya Thangavelu, Neng Chen
ARUP Laboratories: Sarah South, Art Brothman
University of California, San Francisco: Jingwei Yu
Signature Genomics: Lisa Shaffer, Beth Torchia
PathCentral: Mansoor Mohammed, Elaine Luckey
LabCorp of America: Martin Sasaki, Ati Girgin, Monika Skapino, Rosa Thompson, Jose Navarro, and so many more
Natera: Catherine Medina, Rosina Tao, Jonathan Sheena, Hanz Olanan, Anne Nguyen, and so many more
Sterling Pathology: ChangyauYang, Jackie Puma, Kimberly Woodward, Tasha Le, Evelyn Prestano
Epic Sciences: Tara Martinez, Deanna Fisher, Sarah Orr
Allina Health: Sue Kang, Bill Wyatt
Virtual Scientific: Allie Johns
I also wish to acknowledge the College of American Pathology for granting me permission to use their checklist items in this book. I truly appreciate the collegiality of CAP and all its endeavors.
This book is accompanied by a companion website:
www.wiley.com/go/Zneimer/CytogeneticLabManagement
The website includes
Figures
Tables
Textboxes
Standard Operating Procedures/Protocols
Proforma
Guidelines
Good clinical laboratory practice (GCLP) is an essential part of starting and maintaining a clinical laboratory. It is imperative for all of us who direct, manage, and work in clinical laboratories follow certain guidelines encompassing ethical and safety practices in addition to the level of efficiency we desire. GCLP contains standards derived from a combination of Clinical Laboratory Improvement Amendments (CLIA) (portions of 21 CFR part 58 (GLP) and 42 CFR part 493), accrediting bodies such as the College of American Pathologists (CAP) and the International Organization for Standardization (ISO) 15189, and other regulatory authorities and organizations. The British Association of Research Quality Assurance (BARQA) takes a similar approach by combining good clinical practice (GCP) and laboratory practices that are involved in laboratory research activities in Great Britain.
The GCLP standards developed by CLIA were done with the objective of providing a single, unified document that incorporates requirements to guide the conduct of laboratory testing for human clinical trials. However, they are also used in clinical laboratory testing of patients for the diagnosis, prognosis, and screening of human diseases. The intent of GCLP guidance is that when laboratories follow these processes, it ensures the quality and integrity of data, provides accurate reproducibility of experiments and testing, monitors data quality, and allows comparison of test results at any testing facility.
The information that follows synthesizes the GCLP standards based on the guidelines of CAP, CLIA, and ISO in order to facilitate implementation of GCLP for clinical laboratories. A comprehensive version of the GCLP standards with accompanying templates and examples is available at https://www.niaid.nih.gov/LabsAndResources/resources/DAIDSClinRsrch/Documents/gclp.pdf.
Physical facilities
Specimen transport and management
Personnel safety
Laboratory information systems
Quality management
Organization and personnel
Laboratory equipment
Testing operating procedures
By recognizing these standards as the minimum requirements for optimal GCLP, compliance will result in consistent, reproducible, auditable, and reliable laboratory results for clinical testing.
In addition to these good laboratory practice (GLP) standards, other laboratory processes or plans need to be implemented, such as for the instruction of safety, biosafety, and chemical hygiene standards in the laboratory. Also, in the United States, patient health information is protected by law (Health Insurance Portability and Accountability Act (HIPAA)) and a plan must be developed in the laboratory for ensuring the security of patient information. These plans are necessary elements for GCLP and are required before clinical testing can be performed. The following standards for GCLP are outlined in this chapter:
Safety Plan
Biosafety Plan
Chemical Hygiene Plan
HIPAA Plan
These plans can be used by cytogenetic laboratories in order to comply with most regulatory agencies.
For GCLP, it is important to examine the facility you plan to use for your clinical laboratory in a myriad of ways. First, the environment in which laboratory testing is performed must allow efficient operations that do not compromise the safety of the staff or the quality of the preanalytical, analytical, and postanalytical processes. Developing new laboratory space or reconstructing current space needs to be carefully planned to account not just for efficiency and cost, but for the well‐being of the staff and specimen processing. This would include implementing measures to avoid common errors seen in laboratories, such as ensuring enough walkway space, color‐coding, and labeling areas for identification of processing, eliminating clutter, and adding storage space and personal space for the staff.
The laboratory design must account for equipment placement and proper ventilation. It must have a designated area for reagent storage and archiving of data in a secure fireproof, fire‐resistant, or fire‐protected environment with access only to authorized personnel, if possible.
Laboratory work areas must have sufficient space so there is no hindrance to the work or employee safety. Laboratory room (ambient) temperature and humidity must be controlled so that equipment and testing are maintained within the tolerance limits set by the manufacturer or laboratory. Ambient temperature logs should be used to document the acceptable ambient temperature range, record daily actual temperatures, and allow for documentation of corrective action should the acceptable temperature ranges be exceeded. All floors, walls, ceilings, and bench tops of the laboratory must be clean and well maintained.
Molecular amplification procedures within the laboratory that are not contained in closed systems must have a unidirectional workflow. This must include separate areas for specimen preparation, amplification, detection, and reagent preparation to avoid contamination and mix‐ups between test and control specimens.
The accuracy of all laboratory test results depends on the identity and integrity of the specimen submitted. We all know how difficult cytogenetic testing can be when an inappropriate or insufficient quantity of a sample is received for testing or if a sample gets lost in transit or is missing within the laboratory facility. Therefore, it is important to establish a sound specimen tracking system in the laboratory from collection to reporting test results in order to ensure the highest quality data and results. It is also important to ensure that clients sending samples to the laboratory know the laboratory specimen requirements.
The laboratory must also have documented procedures for collection, transportation, and receipt of specimens because the accuracy of all laboratory tests is dependent on specimen quality. A laboratory can only ensure specimen integrity when following appropriate specimen management and transportation procedures.
A properly completed requisition form must accompany each patient sample to the laboratory. The requisition form must contain unique patient identifiers, specimen collection date and time, patient demographics, and specimen type. Laboratory staff should verify that the specimen container with label information matches the requisition form and any log sheet that is present. Any discrepant or missing information must be verified promptly before specimens are processed or stored by the laboratory.
The laboratory must have documented specimen acceptance and rejection criteria for evaluation of sample adequacy and integrity. The laboratory must maintain an audit trail for every specimen from collection to disposal or storage. Audit trails must verify the date and time testing was performed and the personnel responsible for testing. All audit trails must be documented and accessible to auditors.
A shipping procedure must be documented that addresses preparing shipments by following all federal and local transportation of dangerous goods regulations (e.g., International Air Transport Association). Laboratory personnel handling specimens should be trained in hazardous materials/dangerous goods transportation safety regulations. Twenty‐four hour monitoring of storage conditions, using manual and/or electronic monitoring with alert systems, and standard operating procedures (SOPs) for response to alerts must be in place to ensure that the integrity of samples is maintained.
The safety of all laboratory staff is essential to avoid laboratory accidents and to prevent the acquisition of infectious agents through handling of specimens. Although exposure cannot always be avoided, every precaution must be taken to provide a safe working environment. Safety policies that are defined according to regulatory organizations, such as the Occupational Safety and Health Administration (OSHA) or the ISO, must be present in the laboratory.
Standard universal precautions
Chemical hygiene
Hazard communication
Waste management
Safety equipment
General safety and biosafety
These policies are described in more details later in this chapter. However, in general, fire extinguishers, emergency showers, eyewashes, and sharps containers must be present in each laboratory and in compliance with general safety and local laws. Periodic inspections and/or function checks of applicable safety equipment must be documented. The employer must provide the use of personal protective equipment (PPE) and provide access to PPE to all laboratory staff during clinical testing on human specimens. All laboratory employees must use PPE if there is a potential for exposure to blood or other potentially infectious material through any route (e.g., skin, eyes, other mucous membranes). The laboratory must have Safety Data Sheets (SDSs) or equivalent in the workplace for each hazardous chemical they use.
All laboratory staff must also receive safety training. See the Safety Plan further in the chapter for details.
Blood‐borne pathogen handling
Personal protective equipment (PPE) use
Chemical hygiene/hazard communications
Use of safety equipment in the laboratory
Use of cryogenic chemicals (e.g., dry ice and liquid nitrogen)
Transportation of potentially infectious material
Waste management and biohazard containment
General safety and related local laws
The laboratory information system (LIS) is an essential tool to manage complex processes and ensure regulatory compliance and good practice for clinical laboratories. The LIS should be capable of integrating various processes in the laboratory into a single platform with comprehensive specimen processing, reporting, surveillance, and networking capabilities.
The laboratory must maintain a written SOP for the operation of the LIS which should be appropriate and specific to the day‐to‐day activities of the laboratory staff as well as the daily operations of the information technology (IT) staff. Documentation must be maintained, indicating that all users of the computer system received adequate training both initially and after any system modification. Documented procedures and a disaster preparedness plan must exist for the preservation of data and equipment in the case of an unexpected destructive event (e.g., fire, flood, or earthquake), software failure, or hardware failure, allowing for restoring service as quickly as possible.
The purpose of the LIS, its functions, and its interaction with other devices or programs must be documented with validation data and results including data entry, data transmission, calculations, storage, and retrieval. Since patient management decisions are based on laboratory data, appropriate documentation in the LIS must exist to ensure data quality and integrity. Both abnormal and normal data must be used to test the system. Any changes or modifications to the system must be documented, and the laboratory director or designee must approve all changes before they are released for use. Computer time‐stamped audit trails must be used by the LIS. The laboratory’s LIS policies must ensure that LIS access is limited to only authorized individuals.
An overarching quality management (QM) program is essential to ensure the safety of patient samples and maintenance of quality laboratory operations. The QM program is a systematic approach to plan the achievement of quality objectives, comply with approved procedures, and assign specific functional responsibilities to laboratory staff. The QM program should also include a quality assurance (QA) program, which is set up to evaluate the laboratory’s analytical performance by comparing test performances. The following information is an overview of the major components of a good QM program. More detailed information on QM is described in Chapter 2.
The laboratory QM program should be developed as an overall laboratory scope as well to monitor, assess, and correct specific problems identified in each of the preanalytic, analytic, and postanalytic steps in the laboratory testing process. As previously stated, a key component of the QM program is quality assurance (QA). QA must monitor for GCLP compliance, oversee the development of the QM program, and resolve quality‐related problems as described earlier. The QA program should submit status reports to management and must prepare and respond to external audits. It must include evidence of appropriate follow‐up actions taken as a result of monitoring in addition to evaluating the effectiveness of corrective actions.
The laboratory must provide evidence of implementation of the QM program (e.g., minutes of committee meetings, results of ongoing detection of errors, and documented complaint investigations). The laboratory must also be able to provide evidence of appraisal of its QM program. That is, an annual written QM program with revisions including laboratory policies and procedures. QM program documentation must demonstrate at least annual review by the laboratory director or designee. The laboratory’s QM program must include results of ongoing measurement of key quality indicators of laboratory operations compared to internal or external benchmarks and must be monitored for trends over time. The laboratory must be able to use the QM program for guidance when conducting annual appraisals of effectiveness and must provide evidence of the program’s implementation.
Goals and objectives
A design to monitor, evaluate, and correct quality problems
The monitoring of complaints and incidents
The monitoring of all aspects of the laboratory’s scope of care
Addressing problems that interfere with patient care
Describing procedures for collection and communication of quality and safety information (e.g., QC and QA)
Key quality indicators of laboratory operations that target quality improvements (QI measures), such as test turnaround time, specimen acceptability, and test result accuracy
Evidence of a regular review by the laboratory director or designee
The laboratory’s monitoring of the QM program must include an internal audit schedule that contains a comprehensive comparison of the actual practices within the laboratory to the laboratory’s policies and procedures (e.g., personnel files, training documentation, quality control (QC) performance, review of SOPs). Internal audits involve an individual or a group of laboratory personnel performing periodic self‐assessment of actual laboratory practices to see if it matches the laboratory’s policies and procedures. All findings (compliance, noncompliance, or deficiencies) from an internal audit should be documented to allow for appropriate corrective action and follow‐up through resolutions when appropriate. The laboratory should monitor that the QA Program covers all testing assays. The laboratory director or designee must document review of all external quality assurance data, and corrective action should be taken with appropriate preventive measures in response to any unacceptable results, which must be documented.
The laboratory must have a list of assay turnaround times readily available to all laboratory staff as well as laboratory customers. The laboratory must also have a nonretaliatory policy for employees to communicate concerns to laboratory management regarding testing quality or laboratory safety.
Within the QM program, all laboratories must include a QA program.
To provide an internal measurement tool for ensuring that the information a laboratory generates and provides is accurate, timely, clinically appropriate, and useful
To provide regulatory agencies with confidence that individual laboratories are generating data with appropriate measures that will support licensure
To ensure that specimens will be analyzed in a system that provides accurate and reliable results
Therefore, it is critical that laboratories provide a QA program that covers all testing protocols. The laboratory director or designee must review all QA data, and evidence of supervisory review of QA program results must be available (e.g., signature and date of reviewed results and documentation of corrective or preventive actions taken upon unacceptable results). QA specimens must be analyzed, quality assured, and reported in the same manner as patient specimens are tested in the laboratory. As an example, most of the clinical laboratory tests are covered by programs administered through CAP and other organizations.
Laboratories must also have a quality control (QC) program that defines procedures for monitoring analytic performance and consistent identification, documentation, and resolution of QC issues. This is important in detecting errors in a timely fashion as well as changes that occur over time in order to assure the accuracy and reliability of test results. In addition, the laboratory director and/or designee must determine the number and frequency of QC testing and the appropriate QC materials to use.
Test standards and controls
Reagents
Test specimens
Review of quality control data
Quality control logs, labeling of quality control materials and reagents
Inventory control
Parallel testing
Water quality testing
More details of developing a QM program, audit preparation, and QA, QC, and QI programs are discussed in the Chapter 2.
Appropriately trained and well‐organized laboratory staff are critical to the successful operation of a clinical laboratory. Laboratory systems are required to drive organizational structure, training, and ongoing competency assessment to ensure appropriate accountability for analyses of tests. The information that follows is an overview of the necessary laboratory requirements. Further detailed information regarding training and competency is discussed in Section II, Chapters 8–10.
Personnel policies that address such topics as orientation, training, continuing education, performance evaluations, benefits, discipline, dress codes, holidays, security, communication, attendance, and termination
Job descriptions that define qualifications and delegation of duties for all laboratory positions
Personnel files that document each employee’s qualifications, training, continuing education, and competency assessments as they relate to job performance
Organizational charts representing the formal reporting and communication relationships that exist among personnel and management and between the main laboratory unit and satellite units
All laboratory personnel must receive direct and detailed job‐specific training and continuing education to perform all duties so they can understand and competently carry out the necessary SOPs. Competency assessment must be conducted at 6 months of the first year of employment and annually thereafter. Annual evaluations for the employee’s overall performance of job responsibilities, duties, and tasks as outlined in the job description must be given to all laboratory personnel.
The laboratory must employ an adequate number of qualified personnel to perform all of the functions associated with the volume and complexity of tasks and testing performed within the laboratory. All laboratory staff signatures, initials, or codes used as staff identifiers on any laboratory documentation must be linked to a printed name list. This documented list should be a “controlled or traceable version” record that must be updated if changes occur in the laboratory. Signature logs should be archived so that those individuals who performed testing throughout the history of the laboratory are identifiable.
A clinical laboratory continuing education program that is adequate to meet the needs of all personnel must be documented, and evidence of ongoing adherence by all laboratory personnel must be readily available.
Proper maintenance of all laboratory equipment is necessary for assays to function within manufacturers’ specifications. Internal preventive maintenance activities as well as vendor‐provided maintenance and repairs for laboratory equipment are essential in providing accurate and reliable results. Laboratory staff must conduct preventive maintenance and service per manufacturers’ specifications by following documented daily, weekly, and/or monthly routine maintenance plans for all equipment used to ensure that all equipment perform consistently and reproducibly during testing. The laboratory must also document all scheduled preventive maintenance, unscheduled maintenance, service records, and calibrations for all equipment utilized. This documentation should be readily accessible to the lab personnel. The laboratory director or designee must consistently review, sign, and date all documentation at least monthly to establish an audit trail.
The laboratory must also establish tolerance limits for equipment temperatures and other monitored conditions (e.g., % CO2, liquid nitrogen levels) that are consistent with manufacturers’ guidelines and procedural activities, since certain reagents and equipment perform optimally under specific conditions. The lab should also maintain daily records of temperatures and other monitored conditions (e.g., humidity). For observations that fall outside the designated tolerance ranges, the laboratory must maintain appropriate documentation of corrective action for these “out‐of‐range” temperatures and other conditions. More details on reagents, equipment, and instruments are described in Chapter 5.
SOPs are critical for maintaining consistent test performance. The laboratory must write SOPs for all laboratory processes to ensure the consistency, quality, and integrity of test results. Current SOPs must be readily available in the work areas and accessible to testing personnel.
SOPs must be written in a manner and language that is understandable to the laboratory personnel conducting the procedures. SOPs should also be written in a standard format, such as the format recommended by the Clinical and Laboratory Standards Institute (CLSI), formerly the National Accrediting Agency for Clinical Laboratory Sciences (NAACLS). All laboratory personnel must document that they have reviewed and understood all relevant SOPs, so there is evidence that all personnel are knowledgeable in the tasks they perform as part of the laboratory SOPs.
A master list of SOPs currently used in the laboratory