Filling the need for a reference that explains the behavior of power electronic converters, this book provides information currently unavailable in similar texts on power electronics.
Clearly organized into four parts, the first treats the dynamics and control of conventional converters, while the second part covers the dynamics and control of DC-DC converters in renewable energy applications, including an introduction to the sources as well as the design of current-fed converters applying duality-transformation methods. The third part treats the dynamics and control of three-phase rectifiers in voltage-sourced applications, and the final part looks at the dynamics and control of three-phase inverters in renewable-energy applications.
With its future-oriented perspective and advanced, first-hand knowledge, this is a prime resource for researchers and practicing engineers needing a ready reference on the design and control of power electronic converters.
Sie lesen das E-Book in den Legimi-Apps auf:
Seitenzahl: 746
Veröffentlichungsjahr: 2017
Cover
Title Page
Copyright
Preface
About the Authors
Part One: Introduction
Chapter 1: Introduction
1.1 Introduction
1.2 Implementation of Current-Fed Converters
1.3 Dynamic Modeling of Power Electronic Converters
1.4 Linear Equivalent Circuits
1.5 Impedance-Based Stability Assessment
1.6 Time Domain-Based Dynamic Analysis
1.7 Renewable Energy System Principles
1.8 Content Review
References
Chapter 2: Dynamic Analysis and Control Design Preliminaries
2.1 Introduction
2.2 Generalized Dynamic Representations – DC–DC
2.3 Generalized Dynamic Representations: DC–AC, AC–DC, and AC–AC
2.4 Small-Signal Modeling
2.5 Control Design Preliminaries
2.6 Resonant LC-Type Circuits
References
Part Two: Voltage-Fed DC–DC Converters
Chapter 3: Dynamic Modeling of Direct-on-Time Control
3.1 Introduction
3.2 Direct-on-Time Control
3.3 Generalized Modeling Technique
3.4 Fixed-Frequency Operation in CCM
3.5 Fixed-Frequency Operation in DCM
3.6 Source and Load Interactions
3.7 Impedance-Based Stability Issues
3.8 Dynamic Review
References
Chapter 4: Dynamic Modeling of Current-Mode Control
4.1 Introduction
4.2 Peak Current Mode Control
4.3 Average Current-Mode Control
4.4 Variable-Frequency Control
4.5 Source and Load Interactions
4.6 Impedance-Based Stability Issues
4.7 Dynamic Review
4.8 Critical Discussions on PCM Models and Their Validation
References
Chapter 5: Dynamic Modeling of Current-Output Converters
5.1 Introduction
5.2 Dynamic Modeling
5.3 Source and Load Interactions
5.4 Impedance-Based Stability Issues
5.5 Dynamic Review
References
Chapter 6: Control Design Issues in Voltage-Fed DC–DC Converters
6.1 Introduction
6.2 Developing Switching and Average Models
6.3 Factors Affecting Transient Response
6.4 Remote Sensing
6.5 Simple Control Design Method
6.6 PCM-Controlled Superbuck Converter: Experimental Examples
6.7 Concluding Remarks
References
Part Three: Current-Fed Converters
Chapter 7: Introduction to Current-Fed Converters
7.1 Introduction
7.2 Duality Transformation Basics
7.3 Duality-Transformed Converters
7.4 Input Capacitor-Based Converters
References
Chapter 8: Dynamic Modeling of DDR-Controlled CF Converters
8.1 Introduction
8.2 Dynamic Models
8.3 Source and Load Interactions
8.4 Impedance-Based Stability Assessment
8.5 Output-Voltage Feedforward
8.6 Dynamic Review
References
Chapter 9: Dynamic Modeling of PCM/PVM-Controlled CF Converters
9.1 Introduction
9.2 Duty-Ratio Constraints and Dynamic Models under PCM Control
9.3 Duty-Ratio Constraints and Dynamic Models under PVM Control
9.4 Concluding Remarks
References
Chapter 10: Introduction to Photovoltaic Generator
10.1 Introduction
10.2 Solar Cell Properties
10.3 PV Generator
10.4 MPP Tracking Methods
10.5 MPP Tracking Design Issues
10.6 Concluding Remarks
References
Chapter 11: Photovoltaic Generator Interfacing Issues
11.1 Introduction
11.2 Centralized PV System Architecture
11.3 Distributed PV System Architectures
11.4 PV Generator-Induced Effects on Interfacing-Converter Dynamics
11.5 Stability Issues in PV Generator Interfacing
11.6 Control Design Issues
References
Part Four: Three-Phase Grid-Connected Converters
Chapter 12: Dynamic Modeling of Three-Phase Inverters
12.1 Introduction
12.2 Dynamic Model of Voltage-Fed Inverter
12.3 Dynamic Model of Current-Fed Inverter
12.4 Source-Affected Dynamics of Current-Fed Inverter
12.5 Dynamic Model of Current-Fed Inverter with LCL-Filter
12.6 Summary
Appendix 12.A
References
Chapter 13: Control Design of Grid-Connected Three-Phase Inverters
13.1 Introduction
13.2 Synchronous Reference Frame Phase-Locked-Loop
13.3 AC Current Control
13.4 Decoupling Gains
13.5 Grid Voltage Feedforward
13.6 Cascaded Control Scheme in Current-Fed Inverters
13.7 Case Study: Instability Due to RHP-Pole
13.8 Summary
References
Chapter 14: Reduced-Order Closed-Loop Modeling of Inverters
14.1 Introduction
14.2 Reduced-Order Model of Voltage-Fed Inverter
14.3 Reduced-Order Model of Current-Fed Inverter with L-Type Filter
14.4 Closed-Loop Model of Current-Fed Inverter with LC-Type Filter
14.5 Summary
References
Chapter 15: Multivariable Closed-Loop Modeling of Inverters
15.1 Introduction
15.2 Full-Order Model of Current-Fed Inverter with L-Type Filter
15.3 Experimental Verification of Admittance Model
15.4 Full-Order Model of Current-Fed Inverter with LCL-Type Filter
15.5 Summary
References
Chapter 16: Impedance-Based Stability Assessment
16.1 Introduction
16.2 Modeling of Three-Phase Load Impedance in the dq-Domain
16.3 Impedance-Based Stability Criterion
16.4 Case Studies
16.5 Summary
References
Chapter 17: Dynamic Modeling of Three-Phase Active Rectifiers
17.1 Introduction
17.2 Open-Loop Dynamics
17.3 Verification of Open-Loop Model
17.4 Experimental Results
17.5 Summary
References
Index
End User License Agreement
Table 4.1
Table 4.2
Table 12.1
Table 12.2
Table 12.3
Table 12.4
Table 12.5
Table 13.1
Table 13.2
Table 14.1
Table 15.1
Table 15.2
Table 15.3
Table 15.4
Table 17.1
Figure 1.1
Figure 1.2
Figure 1.3
Figure 1.4
Figure 1.5
Figure 1.6
Figure 1.7
Figure 1.8
Figure 1.9
Figure 1.10
Figure 1.11
Figure 1.12
Figure 1.13
Figure 1.14
Figure 1.15
Figure 1.16
Figure 1.17
Figure 1.18
Figure 1.19
Figure 1.20
Figure 1.21
Figure 1.22
Figure 1.23
Figure 1.24
Figure 1.25
Figure 1.26
Figure 1.27
Figure 1.28
Figure 2.1
Figure 2.2
Figure 2.3
Figure 2.4
Figure 2.5
Figure 2.6
Figure 2.7
Figure 2.8
Figure 2.9
Figure 2.10
Figure 2.11
Figure 2.12
Figure 2.13
Figure 2.14
Figure 2.15
Figure 2.16
Figure 2.17
Figure 2.18
Figure 2.19
Figure 2.20
Figure 2.21
Figure 2.22
Figure 2.23
Figure 2.24
Figure 2.25
Figure 2.26
Figure 2.27
Figure 2.28
Figure 2.29
Figure 2.30
Figure 2.31
Figure 2.32
Figure 2.33
Figure 2.34
Figure 2.35
Figure 2.36
Figure 2.37
Figure 2.38
Figure 2.39
Figure 2.40
Figure 2.41
Figure 2.42
Figure 2.43
Figure 2.44
Figure 2.45
Figure 2.46
Figure 2.47
Figure 2.48
Figure 2.49
Figure 2.50
Figure 2.51
Figure 2.52
Figure 2.53
Figure 2.54
Figure 2.55
Figure 2.56
Figure 2.57
Figure 2.58
Figure 2.59
Figure 2.60
Figure 2.61
Figure 2.62
Figure 2.63
Figure 2.64
Figure 2.65
Figure 2.66
Figure 2.67
Figure 2.68
Figure 2.69
Figure 2.70
Figure 2.71
Figure 2.72
Figure 2.73
Figure 2.74
Figure 2.75
Figure 2.76
Figure 2.77
Figure 2.78
Figure 2.79
Figure 2.80
Figure 2.81
Figure 2.82
Figure 2.83
Figure 2.84
Figure 2.85
Figure 2.86
Figure 2.87
Figure 2.88
Figure 2.89
Figure 2.90
Figure 3.1
Figure 3.2
Figure 3.3
Figure 3.4
Figure 3.5
Figure 3.6
Figure 3.7
Figure 3.8
Figure 3.9
Figure 3.10
Figure 3.11
Figure 3.12
Figure 3.13
Figure 3.14
Figure 3.15
Figure 3.16
Figure 3.17
Figure 3.18
Figure 3.19
Figure 3.20
Figure 3.21
Figure 3.22
Figure 3.23
Figure 3.24
Figure 3.25
Figure 3.26
Figure 3.27
Figure 3.28
Figure 3.29
Figure 3.30
Figure 3.31
Figure 3.32
Figure 3.33
Figure 4.1
Figure 4.2
Figure 4.3
Figure 4.4
Figure 4.5
Figure 4.6
Figure 4.7
Figure 4.8
Figure 4.9
Figure 4.10
Figure 4.11
Figure 4.12
Figure 4.13
Figure 4.14
Figure 4.15
Figure 4.16
Figure 4.17
Figure 4.18
Figure 4.19
Figure 4.20
Figure 4.21
Figure 4.22
Figure 4.23
Figure 4.24
Figure 4.25
Figure 4.26
Figure 4.27
Figure 4.28
Figure 4.29
Figure 4.30
Figure 4.31
Figure 4.32
Figure 4.33
Figure 4.34
Figure 4.35
Figure 4.36
Figure 4.37
Figure 5.1
Figure 5.2
Figure 5.3
Figure 5.4
Figure 5.5
Figure 5.6
Figure 5.7
Figure 5.8
Figure 6.1
Figure 6.2
Figure 6.3
Figure 6.4
Figure 6.5
Figure 6.6
Figure 6.7
Figure 6.8
Figure 6.9
Figure 6.10
Figure 6.11
Figure 6.12
Figure 6.13
Figure 6.14
Figure 6.15
Figure 6.16
Figure 6.17
Figure 6.18
Figure 6.19
Figure 6.20
Figure 6.21
Figure 6.22
Figure 6.23
Figure 6.24
Figure 6.25
Figure 6.26
Figure 6.27
Figure 6.28
Figure 6.29
Figure 6.30
Figure 6.31
Figure 6.32
Figure 6.33
Figure 6.34
Figure 6.35
Figure 6.36
Figure 6.37
Figure 6.38
Figure 6.39
Figure 6.40
Figure 6.41
Figure 6.42
Figure 6.43
Figure 6.44
Figure 6.45
Figure 6.46
Figure 6.47
Figure 6.48
Figure 6.49
Figure 6.50
Figure 6.51
Figure 6.52
Figure 6.53
Figure 6.54
Figure 6.55
Figure 6.56
Figure 6.57
Figure 6.58
Figure 6.59
Figure 6.60
Figure 6.61
Figure 6.62
Figure 6.63
Figure 6.64
Figure 6.65
Figure 6.66
Figure 6.67
Figure 7.1
Figure 7.2
Figure 7.3
Figure 7.4
Figure 7.5
Figure 7.6
Figure 7.7
Figure 7.8
Figure 7.9
Figure 7.10
Figure 7.11
Figure 7.12
Figure 7.13
Figure 7.14
Figure 7.15
Figure 7.16
Figure 8.1
Figure 8.2
Figure 8.3
Figure 8.4
Figure 8.5
Figure 8.6
Figure 8.7
Figure 8.8
Figure 8.9
Figure 8.10
Figure 8.11
Figure 8.12
Figure 8.13
Figure 8.14
Figure 8.15
Figure 8.16
Figure 8.17
Figure 8.18
Figure 8.19
Figure 8.20
Figure 9.1
Figure 9.2
Figure 9.3
Figure 9.4
Figure 9.5
Figure 9.6
Figure 9.7
Figure 9.8
Figure 10.1
Figure 10.2
Figure 10.3
Figure 10.4
Figure 10.5
Figure 10.6
Figure 10.7
Figure 10.8
Figure 10.9
Figure 10.10
Figure 10.11
Figure 10.12
Figure 10.13
Figure 10.14
Figure 10.15
Figure 10.16
Figure 10.17
Figure 10.18
Figure 10.19
Figure 10.20
Figure 10.21
Figure 10.22
Figure 10.23
Figure 10.24
Figure 10.25
Figure 10.26
Figure 10.27
Figure 10.28
Figure 10.29
Figure 10.30
Figure 10.31
Figure 10.32
Figure 10.33
Figure 10.34
Figure 10.35
Figure 10.36
Figure 10.37
Figure 10.38
Figure 10.39
Figure 11.1
Figure 11.2
Figure 11.3
Figure 11.4
Figure 11.5
Figure 11.6
Figure 11.7
Figure 11.8
Figure 11.9
Figure 11.10
Figure 11.11
Figure 11.12
Figure 11.13
Figure 11.14
Figure 11.15
Figure 11.16
Figure 11.17
Figure 11.18
Figure 11.19
Figure 11.20
Figure 11.21
Figure 11.22
Figure 11.23
Figure 11.24
Figure 11.25
Figure 11.26
Figure 11.27
Figure 11.28
Figure 11.29
Figure 11.30
Figure 11.31
Figure 11.32
Figure 11.33
Figure 11.34
Figure 11.35
Figure 12.1
Figure 12.2
Figure 12.3
Figure 12.4
Figure 12.5
Figure 12.6
Figure 12.7
Figure 12.8
Figure 12.9
Figure 12.10
Figure 12.11
Figure 12.12
Figure 12.13
Figure 12.14
Figure 12.15
Figure 12.16
Figure 12.17
Figure 12.18
Figure 12.19
Figure 12.20
Figure 12.21
Figure 12.22
Figure 12.23
Figure 12.24
Figure 12.25
Figure 12.26
Figure 12.27
Figure 12.28
Figure 12.29
Figure 12.30
Figure 12.31
Figure 12.32
Figure 12.33
Figure 12.34
Figure 13.1
Figure 13.2
Figure 13.3
Figure 13.4
Figure 13.5
Figure 13.6
Figure 13.7
Figure 13.8
Figure 13.9
Figure 13.10
Figure 13.11
Figure 13.12
Figure 13.13
Figure 13.14
Figure 13.15
Figure 13.16
Figure 13.17
Figure 13.18
Figure 13.19
Figure 13.20
Figure 13.21
Figure 13.22
Figure 13.23
Figure 13.24
Figure 13.25
Figure 13.26
Figure 13.27
Figure 13.28
Figure 13.29
Figure 13.30
Figure 13.31
Figure 13.32
Figure 13.33
Figure 13.34
Figure 13.35
Figure 13.36
Figure 13.37
Figure 13.38
Figure 13.39
Figure 13.40
Figure 13.41
Figure 13.42
Figure 13.43
Figure 13.44
Figure 13.45
Figure 13.46
Figure 13.47
Figure 13.48
Figure 13.49
Figure 13.50
Figure 13.51
Figure 13.52
Figure 13.53
Figure 13.54
Figure 13.55
Figure 13.56
Figure 13.57
Figure 13.58
Figure 13.59
Figure 13.60
Figure 13.61
Figure 13.62
Figure 13.63
Figure 13.64
Figure 13.65
Figure 13.66
Figure 14.1
Figure 14.2
Figure 14.3
Figure 14.4
Figure 14.5
Figure 14.6
Figure 14.7
Figure 14.8
Figure 14.9
Figure 14.10
Figure 14.11
Figure 14.12
Figure 14.13
Figure 14.14
Figure 14.15
Figure 14.16
Figure 14.17
Figure 14.18
Figure 14.19
Figure 14.20
Figure 14.21
Figure 14.22
Figure 14.23
Figure 14.24
Figure 14.25
Figure 14.26
Figure 14.27
Figure 14.28
Figure 14.29
Figure 14.30
Figure 14.31
Figure 14.32
Figure 14.33
Figure 14.34
Figure 14.35
Figure 14.36
Figure 14.37
Figure 14.38
Figure 14.39
Figure 14.40
Figure 14.41
Figure 14.42
Figure 14.43
Figure 14.44
Figure 14.45
Figure 14.46
Figure 14.47
Figure 14.48
Figure 15.1
Figure 15.2
Figure 15.3
Figure 15.4
Figure 15.5
Figure 15.6
Figure 15.7
Figure 15.8
Figure 15.9
Figure 15.10
Figure 15.11
Figure 15.12
Figure 15.13
Figure 15.14
Figure 15.15
Figure 15.16
Figure 15.17
Figure 15.18
Figure 15.19
Figure 15.20
Figure 15.21
Figure 15.22
Figure 15.23
Figure 15.24
Figure 15.25
Figure 15.26
Figure 15.27
Figure 15.28
Figure 15.29
Figure 16.1
Figure 16.2
Figure 16.3
Figure 16.4
Figure 16.5
Figure 16.6
Figure 16.7
Figure 16.8
Figure 16.9
Figure 16.10
Figure 16.11
Figure 16.12
Figure 16.13
Figure 16.14
Figure 16.15
Figure 16.16
Figure 16.17
Figure 16.18
Figure 17.1
Figure 17.2
Figure 17.3
Figure 17.4
Figure 17.5
Figure 17.6
Figure 17.7
Figure 17.8
Figure 17.9
Figure 17.10
Figure 17.11
Figure 17.12
Figure 17.13
Figure 17.14
Figure 17.15
Cover
Table of Contents
Begin Reading
Part 1
Chapter 1
iii
iv
xiii
xiv
xv
xvi
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
Teuvo Suntio, Tuomas Messo, and Joonas Puukko
All books published by Wiley-VCH are carefully produced. Nevertheless, authors, editors, and publisher do not warrant the information contained in these books, including this book, to be free of errors. Readers are advised to keep in mind that statements, data, illustrations, procedural details or other items may inadvertently be inaccurate.
Library of Congress Card No.: applied for
British Library Cataloguing-in-Publication Data
A catalogue record for this book is available from the British Library.
Bibliographic information published by the Deutsche Nationalbibliothek
The Deutsche Nationalbibliothek lists this publication in the Deutsche Nationalbibliografie; detailed bibliographic data are available on the Internet at <http://dnb.d-nb.de>.
© 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Boschstr. 12, 69469 Weinheim, Germany
All rights reserved (including those of translation into other languages). No part of this book may be reproduced in any form – by photoprinting, microfilm, or any other means – nor transmitted or translated into a machine language without written permission from the publishers. Registered names, trademarks, etc. used in this book, even when not specifically marked as such, are not to be considered unprotected by law.
Print ISBN: 978-3-527-34022-4
ePDF ISBN: 978-3-527-69851-6
ePub ISBN: 978-3-527-69853-0
Mobi ISBN: 978-3-527-69854-7
oBook ISBN: 978-3-527-69852-3
Rigid voltage sources, such as an ideal grid, an output-voltage feedback-controlled converter, and a storage battery, have dominated as input sources for a long time. As a consequence, the scholars and engineers have learned every detail and developed a multitude of power stages and control methods for the voltage domain. A common characteristic of these sources is that their output impedance is low in magnitude at low frequencies. From time to time, a term current-sourced converter has been used with a voltage-sourced converter in case there is an inductor connected in series with the voltage-type source. Unfortunately, such a converter has no explicit relation to the current source as an input source. However, duality implies that there also exist sources that can be classified as real current sources, that is, sources that have an output impedance, which is high in magnitude.
Since the last decade, people have started paying more and more attention on renewable energy sources for providing pollution-free energy and ensuring energy availability also in the future. Usually, most of the power electronic converters applied in interfacing the renewable energy sources into power grid in grid-feeding mode are to be considered as current-fed converters due to the feedback control of DC voltage. Despite the real nature of the input source, the scholars and engineers still like to consider them as voltage sources and justify their opinions by means of Norton–Thevenin transformation. The dual nature of the photovoltaic generators (i.e., current and voltage at specific operation points of their current–voltage curve) makes them an input source that may be too confusing for an engineer to analyze and thus the analysis will be performed in the familiar voltage domain even though such a power source will significantly affect the dynamic behavior of the converters connected at their output terminals. The long history of voltage sources as the dominating input source has created a situation, which has prevented the full understanding of the special features introduced by the current sources as input sources. This is quite understandable, because the most difficult learning process is to learn out from the past.
This book contains material from both of the domains by using the same power stage powered either by the rigid voltage or the current source. The differences in the dynamic behavior of the converters in different domains are explicitly shown including also comprehensive analyses of the source and load interactions in DC–DC converter as well as in grid-connected three-phase converters. Similar material cannot be found from any available book and the material in scientific papers is scarce and may be hard to identify from the vast number of published papers.
Many individuals have helped us to create the book during the past 20 years in academy. Most of those individuals are our past Ph.D. students and colleagues at TUT, who have created new knowledge during the research projects we have conducted together. We appreciate very much the Finnish industry and funding organizations, who have helped us to fund the research.
Tampere University of TechnologyTampere, FinlandTeuvo Suntio
Tampere University of TechnologyTampere, FinlandTuomas Messo
ABB OyHelsinki, FinlandJoonas Puukko
Teuvo Suntio received his Ph.D. degree in electrical engineering in 1992 from Helsinki University of Technology, Finland. After several R&D engineering and managerial positions during the 22 years in Power Electronics Industry, he accepted a post as a Professor in 1998 in the Electronics Laboratory at University of Oulu, Finland, before moving to Department of Electrical Engineering, Tampere University of Technology in 2004, which is the post he still holds. Professor Suntio's current research interests include dynamic characterization and control of power electronic converters and systems, especially in renewable energy applications. He holds several international patents and has authored or coauthored over 230 international journal and conference publications. He is a Senior Member of IEEE, and has served as an associate editor in IEEE Transactions on Power Electronics since 2010.
Tuomas Messo was born in 1985 in Hämeenlinna, Finland. He finalized his M.Sc. and Ph.D. degrees in electrical engineering at Tampere University of Technology (TUT), Tampere, Finland in 2011 and 2014, respectively.
In 2014–2015, he worked as Post-Doctoral Researcher at TUT and in 2016 he was appointed as an Assistant Professor (Tenure Track) in the field of power electronics. He is currently working at the Laboratory of Electrical Energy Engineering at TUT where he carries out lecturing, research, and supervision of electrical engineering students of all degrees.
His main research interests include dynamic modeling of power converters in renewable energy applications and smart grids, impedance-based stability analysis, frequency-domain measurements, control design, and stability analysis of control systems.
Joonas Puukko was born in Helsinki, Finland. He has M.Sc. and Ph.D. degrees (both with distinction) in electrical engineering from the Tampere University of Technology, Tampere, Finland.
He was previously working at ABB Solar Inverters in Helsinki, Finland and ABB Corporate Research Raleigh, NC, USA. At the moment, he is with ABB High Power Drives in Helsinki, Finland. His research interests include power electronics in a range of applications from drives to interfacing of renewable energy systems with the utility grid. He has design experience in wide-bandgap semiconductors, high-frequency magnetics, and frequency-domain modeling/verification.
For a long time, voltage-type sources such as storage battery, AC grid, and output-voltage-regulated converters have dominated as an input source for power electronic converters [1,2]. These sources are usually referred to as rigid sources, since the load has limited influence on their operating voltage. Both awareness on the depletion of fossil fuel reserves and their impact on the observed climate changes have accelerated the utilization of renewable energy sources, for example, wind and solar [3]. Effective large-scale utilization of these energy sources requires the use of grid-interfaced power electronic converters [4,5]. It has been recently concluded [6,7] that the power electronic converters used in the photovoltaic (PV) systems are essentially current-sourced converters because of the current-source properties of PV generator [8,9] forced by the input-side voltage feedback control [10,11]. At open loop, the static and dynamic properties of the integrating converter are determined by the operating region of the PV generator. The same also applies for the converters in wind energy systems. Another example of a perfect current source is superconducting magnetic energy storage (SMES) system, where a very large inductor serves as the energy storage element [12,13]. Even though the properties of the mentioned sources are already well known [14,15], they are still typically considered as voltage sources when designing the interfacing converter power stages [16,17] or analyzing their underlying dynamics [18–21] despite their current-type properties. The analysis method is usually justified by Norton/Thevenin transformation [20].
The existence of two different input source types implies that two different families of power electronic converters shall also exist, where the converters shall be referred to as voltage-fed (VF) (Figure 1.1) and current-fed (CF) (Figure 1.2) converters, possessing different steady-state and dynamic properties even though the power stage can be the same in both of the cases [7,22]. The term current source has already been widely used, for example, in Ref. [23–28], denoting a voltage-fed converter, where an inductor is placed on the input-side current path such as a boost-type converter [29] or two-inductor (super)buck converter [30]. Fuel cells as renewable energy sources [31] are such an input source, which can be considered to be either voltage or current sources due to their rather constant output impedance [32] and operation at the voltages less than the maximum power point [33]. Therefore, the elimination of the harmful low-frequency ripple can be performed by using either input current (i.e., voltage source) or input voltage (i.e., current source) feedback control [34].
Figure 1.1 VF converter. (a) VO mode. (b) CO mode. Source: Suntio 2014. Reproduced with permission of IEEE.
Figure 1.2 CF converter. (a) CO mode. (b) VO mode. Source: Suntio 2014. Reproduced with permission of IEEE.
On the load side, the output voltage of a converter shall not be taken automatically as an output variable, since this is true only when the converter serves as a typical power supply, regulating its output voltage. In case, the converter is used, for example, as a battery charger or grid-connected inverter, the output voltage is determined by the load-side source and hence output current shall be treated as an output variable. Therefore, the static input-to-output ratio , where denotes the steady-state duty cycle, shall be actually determined as the ratio of the input-terminal variable characterizing the input source and the same variable at the output terminal, that is, the voltage ratio in a VF converter and the current ratio in a CF converter. According to Figures 1.1 and 1.2, the converter may serve either as a VF or as a CF converter with voltage (VO) or current (CO) as its main output variable, depending on the application. In all the cases, the terminal constraints in terms of voltage and current levels remain unchanged. Reference [22] shows explicitly in theory and by experimental measurements that the dynamic behavior changes significantly application by application as demonstrated in Figure 1.3, where the measured frequency responses of the control-to-output transfer functions with different terminal source configurations are shown. Therefore, it is very important to identify the correct nature of the terminal sources when analyzing the dynamics of the converter, for example, for control design purposes, which is obvious when studying the frequency responses in Figure 1.3.
Figure 1.3 The frequency responses of a buck power stage converter when the terminal sources are varied (i.e., voltage-fed converters at voltage (vf/vo) and current (vf/co) output modes and current-fed converters at current (cf/co) and voltage (cf/vo) modes).
Every power electronic converter has unique internal dynamics, which will determine the obtainable transient dynamics and robustness of stability as well as its sensitivity to the external source and load impedances [35–37]. The internal dynamics can be represented by a certain set or sets of transfer functions, which are classified in circuit theory according to the network parameters [38] known as G (Figure 1.1a), Y (Figure 1.1b), H (Figure 1.2a), and Z (Figure 1.2b), respectively. The specific transfer functions can be directly modeled and measured as frequency responses only when the used terminal sources correspond to the ideal terminal sources given for each of the sets in Figures 1.1 and 1.2. Even if the concept of internal dynamics is basically well known (i.e., all effects from the source and load impedances are removed) [7,35], the tendency is still to use a resistor as a load [39] yielding load-affected models or measured frequency responses. A power stage fed by a certain input source under direct duty ratio (DDR) control tends to maintain the output mode the same as the input source (i.e., VF converters are inherently voltage sources at their output, and CF converters are current sources at their output). As a consequence, the internal transfer functions of such converters can be measured directly at open loop. The other possible output mode does not work at open loop due to violation of Kirchhoff's voltage or current law. The same also applies for the current-mode control, which changes the converter to be a current-output converter [40]. In such a case, the use of resistive load is well justified, but the internal transfer functions have to be computed from the load-affected transfer functions for being useful [7].
A large number of excellent power electronics textbooks are available, such as Refs [5,7,25,39,41–47], which are dedicated to the converters providing either DC–DC or DC–AC (AC–DC) conversion, or even both. None of these textbooks presents topics that treat the CF converters even if they exist or may even dominate within the specific application area covered in the specific books. The inclusion of the effect of source and load impedances on the converter dynamics is also usually left out by the topics covered in the books even if they are considered very important in practical applications.
The main goal of this book is to provide the missing information in order to complement the other textbooks as well as to present the base for the dynamic analysis of the converters in a general form, which can be utilized with both analytically derived transfer functions and the experimentally measured transfer functions. As a consequence, the potentials of the theoretical work are extended into practice and for the usage of practicing engineers.
The topics covered in the book are briefly discussed and clarified in the subsequent sections in order to familiarize the reader with the secrets of dynamic modeling, analysis, and control designs in both DC-voltage/current source and AC-voltage/current source domains. The mastering of these items requires quite consistent thinking ability as well as flexibility to change from one set of dynamic descriptions to another while moving on.
There are actually three different methods to implement CF converters: (i) applying capacitive switching cells to construct CF converters [48] similarly as the inductive switching cells are applied, for example, in Refs [1,2], (ii) applying duality transformation methods [49–53], and (iii) adding a capacitor to the input terminal of a VF converter [54] to satisfy the terminal constraints imposed by the input current source [55]. The duality transformation yields CF converters, which retain the main static and dynamic properties characterizing the original VF converter [52]. The adding of a capacitor at the input terminal of a VF converter yields a CF converter having static and dynamic properties resembling the dual of the original converter, that is, a VF buck converter will have characteristics resembling a boost converter and vice versa [54].
As an example, the power stage of a VF buck converter and its dual, that is, the corresponding power stage of a CF buck converter, are given in Figures 1.4 and 1.5. In the original buck converter, the high-side switch conducts during the on-time and the low-side switch during the off-time. In the CF buck converter, the low-side switch conducts during the on-time and the high-side switch during the off-time. As both of the converters are buck-type converters, the ideal input-to-output relation or modulo .
Figure 1.4 VF buck converter.
Figure 1.5 CF buck converter.
It has been observed earlier that the VF-converter power stages used in the interfacing of PV generators exhibit peculiar properties, such as appearing of right-half-plane (RHP) zero in the control dynamics of buck power stage converter [56], unstable operation when the output voltage or current is tightly controlled [57], necessity to reduce the pulsewidth for increasing the output variables [58,59], and appearing of RHP pole when peak-current-mode (PCM) control is applied in a buck power-stage converter [60,61], and even the impedance-based stability assessment has to be performed differently compared to the VF converters [62]. The observed phenomena are good evidence for the necessity to fully take into account the used terminal sources as discussed in Ref. [22].
The methods to develop the required small-signal or dynamic models for the power electronic converters date back to the early 1970s [63] when the foundation for the state space averaging (SSA) method was laid down [64] and later modified to correctly capture the dynamics associated with the discontinuous conduction mode (DCM) of operation [65,66] as well as with the variable frequency operation [67,68]. The same methods also apply equally to modeling the dynamics of three-phase grid-connected power converters [69]. The SSA method is observed to produce accurate models up to half the switching frequency.
One of the most fundamental issues in performing the modeling in addition to the recognition of the correct input and output variables is that the state variables are to be considered as the time-varying average values within one switching cycle of the corresponding instantaneous values [66]. In continuous conduction mode (CCM), this is also true in the instantaneous state variables and, therefore, the averaged state space can be constructed by computing the required items directly by applying circuit theory. The continuity is also reflected as the known length of the on-time and off-time. In DCM, the instantaneous variables are not anymore necessarily continuous signals but rather pulsating signals, which is also reflected as the unknown length of off-time. Therefore, their time-varying average values have to be computed based on the wave shapes of their instantaneous values and used for computing the length of the unknown off-time. A number of variants are available for the basic SSA method in continuous time as well as in discrete time, which can also be used for obtaining the dynamic models but they do not offer usually such benefits, which would justify their usage in practical applications.
The original SSA method can be applied as such only to the converters, which operate in CCM under DDR control, which is also known as voltage-mode (VM) control [39]. The last term is not recommended, however, to be used, because it will mean in the future the internal control methods in a CF converter, where the feedback is taken from the capacitor voltage (i.e., peak voltage mode (PVM) or average voltage mode (AVM)) similarly as the current-mode controls (i.e., peak current (PCM) or average current (ACM)) in a VF converter. The dynamic models (i.e., the small-signal state space) induced by the DDR control will serve as the base for the modeling of the converters, where the internal feedback loops are used to affect the duty ratio generation, that is, the dynamics associated with the duty ratio. The modeling of those converters can be simply done by developing proper duty-ratio constraints, where the perturbed duty ratio is expressed as a function of the state and input variables of the converter [7]. In case of variable-frequency operation, the duty ratio is nonlinear and, therefore, the on-time of the switches has to be used as the control variable instead of duty ratio [7,68].
As an outcome of the SSA modeling method [64], the dynamics of the associated converter was represented by means of the canonical equivalent circuit given in Figure 1.6, which is valid for a second-order or two-memory-element converter operating in CCM under DDR control. The structure and the circuit elements of the equivalent circuit can be found from the corresponding small-signal state space. Similar equivalent circuit can also be constructed for the higher order converters as well as for CF converters (see Figure 1.7) applying the same methodology. Figures 1.6 and 1.7 provide clear physical insight into the dynamic processes inside the converters as well as clearly indicate the differences the duality transformation produces in the converter. As being a linear representation of the converter, the effect of the source and load impedances can be computed by applying circuit theory, which is very important for understanding the dynamic behavior of the practical systems.
Figure 1.6 Canonical equivalent circuit for a second-order VF/VO converter.
Figure 1.7 Canonical equivalent circuit for a second-order CF/CO converter.
Similar equivalent circuits as in Figures 1.6 and 1.7 cannot be, however, constructed for the converters operating in DCM or containing internal feedbacks, for example, PCM control. More general equivalent circuit can be constructed based on the set of transfer functions comprising the network parameters G, Y, H, and Z, which can be utilized similarly as the canonical equivalent circuits in Figures 1.6 and 1.7 to assess the effect of nonideal source and load [7,70]. Figures 1.8 and 1.9 show such a generic equivalent circuit representing the dynamics of VF/VO DC–DC and a VF/CO DC–DC converters, respectively. On comparing the equivalent circuits in Figures 1.6 and 1.7 with the equivalent circuits in Figures 1.8 and 1.9, the main difference found between them is that the latter equivalent circuits present explicitly the main terminal characteristics of a converter. This information is actually very important for being able to fulfill the terminal constraints stipulated by the different input and output sources.
Figure 1.8 Generic equivalent circuit for a VF/VO converter.
Figure 1.9 Generic equivalent circuit for a CF/CO converter.
Similar equivalent circuits as in Figures 1.6 and 1.7 can also be constructed for the three-phase grid-connected converters by means of their small-signal state space given in the synchronous reference frame applying power invariant transformation (i.e., power-invariant d–q state space), as shown in Figures 1.10 and 1.11 [71,72]. The corresponding physical schematics are given in Figures 1.12and 1.13, respectively. According to Figures 1.12 and 1.13, the converters can be constructed from each other by changing the direction of power flow. This similarity is also visible in the corresponding equivalent circuits. These equivalent circuits would give the same physical insight as the corresponding DC–DC equivalent circuits.
Figure 1.10 Canonical equivalent circuit for a three-phase AC–DC converter.
Figure 1.11 Canonical equivalent circuit for a current-fed three-phase DC–AC converter.
Figure 1.12 Three-phase grid-connected rectifier.
Figure 1.13 Three-phase grid-connected current-fed inverter.
Similar equivalent circuits as in Figures 1.10 and 1.11 cannot be, however, constructed for the converters operating in DCM or containing internal feedbacks. Similarly, as in the case of DC–DC converters, the more general equivalent circuits can be constructed based on the set of transfer functions comprising the network parameters G, Y, H, and Z, which can be utilized similarly as the canonical equivalent circuits in Figures 1.10 and 1.11 to assess the effect of nonideal source and load [7,73]. Figure 1.14 shows such a generic equivalent circuit representing the dynamics of a three-phase grid-connected AC–DC converter, and Figure 1.15 shows a generic equivalent circuit representing the dynamics of a three-phase grid-connected current-fed inverter. On comparing the equivalent circuits in Figures 1.10 and 1.11 with the equivalent circuits in Figures 1.14 and 1.15, the main difference found between them is that the latter equivalent circuits present explicitly the main terminal characteristics of a converter. This information is actually very important for being able to fulfill the terminal constraints stipulated by the different input and output sources.
Figure 1.14 Generic equivalent circuit for a three-phase grid-connected VF/VO converter.
Figure 1.15 Generic equivalent circuit for a three-phase grid-connected CF/CO converter.
The variables of the equivalent circuits with a superscript s denote the three-phase variables transformed into the synchronous reference frame (SRF) composed of direct (d) and quadrature (q) components of the variables, respectively. The transfer functions represented with boldface letters denote a transfer function matrix composed of two or four discrete transfer functions. The computation of the effect of nonideal source and load has to be performed by applying matrix manipulation techniques instead of circuit theoretical methods [73].
The generic equivalent circuits are very flexible tools for solving the dynamic problems associated with the impedance-based interactions [37,71,74] as well as for assessing the stability in the practical interconnected systems [75,76]. The dynamic equivalent circuits as well as the corresponding matrix-form representations can be equally utilized by means of the model-based analytic transfer functions and the corresponding measured frequency responses or even by their combination.
Stability assessment of a system composed of interconnected power electronic converters as well as passive impedance-like elements can be effectively performed at any interface within the system by means of the ratio of upstream and downstream impedances measured or predicted at the interface [7,22,63,75–84]. The method was originally launched in Refs [77,78] for designing stable input-filter converter systems. The ratio was named as minor loop gain, where the input-filter output impedance is the upstream impedance and the input impedance of the converter is the downstream impedance. The minor loop gain denotes the ratio of the upstream and downstream impedances. The stability of the interconnected system is retained when the minor loop gain satisfies Nyquist stability criterion. It has been later observed that the original minor loop gain is only valid for a certain type of interfaces, that is, the upstream subsystem is a voltage-type system and the downstream system a current-type system. A general definition for the construction of the minor loop gain is such that the numerator impedance shall be the internal impedance of the voltage-type subsystem and the denominator impedance shall be the internal impedance of the current-type subsystem [22,62,78].
The minor loop gain concept is nowadays applied commonly in assessing the stability and transient performance in interconnected power electronic systems. The concept of forbidden region was launched in Ref. [79], which ensures robust stability of the system if the minor loop gain stays out of the forbidden region. The forbidden region launched by Middlebrook in Refs [77,78] is a circle having radius of inverse of gain margin (GM) and the center at origin, as shown in Figure 1.16. Middlebrook's forbidden region was deemed to be too conservative, that is, occupying unnecessary amount of area in the complex plain [79]. As a consequence, new forbidden regions were developed for reducing the conservatism [79–84] such as ESAC (energy systems analysis consortium) [79], GMPM (gain margin phase margin) [80], and opposing argument [81] criteria illustrated in Figure 1.16.
Figure 1.16 Collection of forbidden regions in the complex plane according to Refs [77–84]. Source: Vesti 2013. Reproduced with permission of IEEE.
According to Figure 1.16, all the different criteria aim to maintain robust stability (i.e., acceptable transient performance) by requiring the minor loop gain to satisfy certain PM and GM conditions. Reference [75] proposed a new forbidden region by means of a circle having radius of inverse of maximum peak value allowed in the affected system transfer functions and the center at the point (−1,0) as depicted in Figure 1.17, which outperforms the other earlier launched forbidden regions in terms of occupied area in the complex plain. The forbidden region concept is applicable to DC and AC domain systems as well.
Figure 1.17 Maximum peak criteria (MPC)-based forbidden region versus EASC and GMPM regions [75]. Source: Vesti 2013. Reproduced with permission of IEEE.
Time domain-based dynamic analysis and control design are quite common in control engineering [85,86] and are also utilized in conjunction with the grid-connected power electronics applications [87]. The time domain responses do not, however, reveal the origin of the observed transient behavior or how close the system is for instability. Figure 1.18 shows the output-voltage transient behavior of a buck converter when a step change is applied in the load current without (Figure 1.18a) and with the input LC or EMI filters (Figure 1.18b and c). If both the original and EMI filter-affected responses were not known, then it would be very difficult to distinguish between the poor controller design and other external reasons, because the decaying oscillation at the output-voltage response would be similar with low margins (i.e., PM and GM) in the feedback loop.
Figure 1.18 Output-voltage response of a buck converter to a step change in load current.
Figure 1.19 shows the measured output-voltage feedback loop without and with the input EMI filter. According to Figure 1.19, the EMI filter has not caused such a change in the feedback loop, which would affect the transient response, that is, the PM and GM are not changed. Figure 1.20 shows the measured closed-loop output impedance of the converter, where the EMI filter has created a resonance, which actually initiates the decaying oscillation at the output-voltage response [88,89]. More specifically, the resonance at the output impedance is caused by the interacting EMI-filter output impedance and short-circuit input impedance of the converter [90].
Figure 1.19 The measured original and EMI-filter-affected output-voltage feedback loops.
Figure 1.20 Original and EMI-filter-affected closed-loop output impedances.
Figure 1.21 shows that the grid-connected inverter may become unstable when the control bandwidth of the phase locked loop (PLL) is increased under certain grid impedance conditions. PLL is used for synchronizing the inverter to grid. The reason for the instability is the tendency of the inverter output impedance to have negative resistor-like behavior at low frequencies, that is, at the frequencies lower than the PLL crossover frequency [91]. The frequency responses of the inverter output impedance and the grid impedance (Figure 1.22) can be used to reveal explicitly the problems associated with instability phenomenon. The time domain plot does not tell anything about the reasons behind the problem or how much the condition has to change that the instability will vanish or occur again.
Figure 1.21 Instability of three-phase grid-connected inverter induced by PLL control bandwidth.
Figure 1.22 Effect of the PLL bandwidth on the inverter output impedance.
It may be quite obvious that the time domain evidence does not suffice to proving the quality of design or the validity of the modifications for removing the problem. The frequency domain evidence will provide a medium to assess the robustness of the design as well as to reveal the risks left in the design for reoccurrence of the “removed” problem.
Large-scale utilization of the renewable energy sources such as solar PV, wind, and fuel cells necessitates the use of power electronic converters for providing the grid integration [4]. The solar PV power plants are either constructed by using one DC–AC stage (i.e., single stage) (Figure 1.23) or cascaded by using DC–DC and DC–AC stages (i.e., double stage) (Figure 1.24) [92]. The full-power converter wind energy and fuel cell systems are most often constructed by using double-stage converter schemes according to Figure 1.24 [31,93–95].
Figure 1.23 Single-stage renewable energy system principle.
Figure 1.24 Cascaded renewable energy system principle.
The basic operation mode of these systems in terms of grid connection is either grid-parallel (i.e., grid-feeding, grid-supporting) or grid-forming mode [96–98]. In grid-parallel operation mode, the inverter serves as current source, and the grid determines the level of AC voltage and frequency (Figures 1.25 and 1.26). Usually maximum available power in the renewable energy source is supplied into the grid applying different maximum power point (MPP) tracking algorithms [99–102]. A characteristic of the grid-parallel operation mode is that the outmost feedback loops of the power electronic converters are taken from the input terminal of the converters (see Figures 1.25 and 1.26).
Figure 1.25 Single-stage grid-parallel energy system.
Figure 1.26 Cascaded grid-parallel renewable energy system.
In grid-forming operation mode (i.e., standalone, off-grid, or islanding), the inverter serves as a voltage source taking care of both the voltage level and the frequency (Figures 1.27 and 1.28). The level of output power supplied into the system depends on the load of the system. A characteristic of the grid-forming mode is that the outmost feedback loops are taken from the output terminal of the power electronics converters (see Figures 1.27 and 1.28).
Figure 1.27 Single-stage grid-forming energy system.
Figure 1.28 Cascaded grid-forming renewable energy system.
The feedback arrangements mean that the power electronic converters in grid-parallel mode are CF/CO converters and in grid-forming mode VF/VO converters. The change of operating mode is usually required in renewable energy systems (i.e., from grid-parallel to grid-forming mode and back). The dynamic behavior of the converters will profoundly change depending on the operation mode, which has to be carefully considered when designing the control systems for ensuring stable operation [97].
The book is divided into four parts as follows: Part One, comprising Chapters 1 and 2, is dedicated to the introduction as well as to the dynamic analysis and control design preliminaries in a generalized manner. Part Two, comprising Chapters 3–6, is dedicated to the dynamics of voltage-fed DC–DC converters. Part Three, comprising Chapters 7–11, is dedicated to the dynamics of current-fed DC–DC converters as well as to the properties of photovoltaic generator and its effects on the interfacing converter dynamics. Part Four, comprising Chapters 12–17, is dedicated to the dynamics and control of grid-connected three-phase VSI-type converters. The content of the subsequent chapters is briefly reviewed in order to clarify the message, which each chapter will deliver.
The conceptual and theoretical basis of the book is provided in Chapter 2 in a simple and practical manner without using difficult mathematical treatments, but at the same time in general form. The same theoretical formulas are repeated in explicit modes in the associated chapters if deemed to be necessary for understanding the message.
In Part Two, the dynamic modeling, analysis, and control of VF converters are treated. Chapter 3 provides the unified dynamic modeling of direct-on-time-controlled converters applied to the basic converters (i.e., buck, boost, and buck–boost) as well as to the superbuck or two-inductor buck converter in the fixed-frequency mode of operation. The dynamic models provided by Chapter 3 are utilized to model the dynamic behavior of the current-mode-controlled converters in Chapter 4. The similarity between PCM and ACM controls is clearly pointed out. The modeling of PCM control is also introduced in case of several simultaneous inductor-current-feedback arrangements as well as when coupled inductors are utilized. The source and load interactions in PCM- and DDR-controlled converters are compared and the origin of the differences is explained. Chapter 5 introduces the modeling of current-output converters based on the models of the VF/VO converters. The source and load interactions as well as impedance-based stability analysis are introduced and compared with the VF/VO converters. Chapter 6 is dedicated for the control design issues in VF converters. The factors affecting the load transient response are explicitly explained, which would facilitate the control design.
In Part Three, the implementation, dynamic modeling, analysis, and control of CF converters are treated. Chapter 7 provides the methods to implement CF converters applying duality transformation and adding necessary components at the input terminal for satisfying the terminal constraints imposed by the current-type input source. Chapter 8 provides the dynamic models of DDR-controlled basic CF converters implemented by duality-transformation methods or by adding a capacitor at the input terminal of a VF converter. Chapter 9 introduces the dynamic modeling of PCM- and PVM-controlled CF converters. Observed stability problems in conjunction with PCM control applied in PV interfacing converters are explicitly explained. The influence of the PCM and PVM controls in source and load interactions as well as impedance-base stability assessment are explicitly explained. Chapter 10 introduces the characteristics of PV generator as well as the MPP tracking methods and design constraints. Chapter 11 is dedicated to the photovoltaic generator interfacing problematics from the power electronics converter viewpoint, including the PV generator-induced effects on the dynamics of the interfacing converters as well as the associated stability issues.
In Part Four, the dynamic modeling, analysis, and control of grid-connected three-phase VSI-type converters are treated. Chapter 12 provides consistent methods to develop the dynamic models of voltage- and current-fed three-phase PWM inverters in synchronous reference frame (or dq-domain) by utilizing space vector theory. Chapter 13 is dedicated to applying the dynamic models to design the required control functions in an inverter. The effect of different control anomalies caused by the input terminal sources are explicitly treated as well. Chapter 14 introduces reduced-order dynamic modeling of the inverters to relax the high complexity of the inverter dynamics for achieving satisfactory dynamic descriptions applicable for control design. Chapter 15 provides the detailed models for analyzing the closed-loop dynamics of the inverter in multivariable environment. Chapter 16 provides detailed information on the impedance-ratio-based stability assessment methods applying generalized Nyquist stability criterion. Chapter 17