Power Electronic Converters - Teuvo Suntio - E-Book

Power Electronic Converters E-Book

Teuvo Suntio

0,0
297,99 €

-100%
Sammeln Sie Punkte in unserem Gutscheinprogramm und kaufen Sie E-Books und Hörbücher mit bis zu 100% Rabatt.

Mehr erfahren.
Beschreibung

Filling the need for a reference that explains the behavior of power electronic converters, this book provides information currently unavailable in similar texts on power electronics.

Clearly organized into four parts, the first treats the dynamics and control of conventional converters, while the second part covers the dynamics and control of DC-DC converters in renewable energy applications, including an introduction to the sources as well as the design of current-fed converters applying duality-transformation methods. The third part treats the dynamics and control of three-phase rectifiers in voltage-sourced applications, and the final part looks at the dynamics and control of three-phase inverters in renewable-energy applications.

With its future-oriented perspective and advanced, first-hand knowledge, this is a prime resource for researchers and practicing engineers needing a ready reference on the design and control of power electronic converters.

Sie lesen das E-Book in den Legimi-Apps auf:

Android
iOS
von Legimi
zertifizierten E-Readern

Seitenzahl: 746

Veröffentlichungsjahr: 2017

Bewertungen
0,0
0
0
0
0
0
Mehr Informationen
Mehr Informationen
Legimi prüft nicht, ob Rezensionen von Nutzern stammen, die den betreffenden Titel tatsächlich gekauft oder gelesen/gehört haben. Wir entfernen aber gefälschte Rezensionen.



CONTENTS

Cover

Title Page

Copyright

Preface

About the Authors

Part One: Introduction

Chapter 1: Introduction

1.1 Introduction

1.2 Implementation of Current-Fed Converters

1.3 Dynamic Modeling of Power Electronic Converters

1.4 Linear Equivalent Circuits

1.5 Impedance-Based Stability Assessment

1.6 Time Domain-Based Dynamic Analysis

1.7 Renewable Energy System Principles

1.8 Content Review

References

Chapter 2: Dynamic Analysis and Control Design Preliminaries

2.1 Introduction

2.2 Generalized Dynamic Representations – DC–DC

2.3 Generalized Dynamic Representations: DC–AC, AC–DC, and AC–AC

2.4 Small-Signal Modeling

2.5 Control Design Preliminaries

2.6 Resonant LC-Type Circuits

References

Part Two: Voltage-Fed DC–DC Converters

Chapter 3: Dynamic Modeling of Direct-on-Time Control

3.1 Introduction

3.2 Direct-on-Time Control

3.3 Generalized Modeling Technique

3.4 Fixed-Frequency Operation in CCM

3.5 Fixed-Frequency Operation in DCM

3.6 Source and Load Interactions

3.7 Impedance-Based Stability Issues

3.8 Dynamic Review

References

Chapter 4: Dynamic Modeling of Current-Mode Control

4.1 Introduction

4.2 Peak Current Mode Control

4.3 Average Current-Mode Control

4.4 Variable-Frequency Control

4.5 Source and Load Interactions

4.6 Impedance-Based Stability Issues

4.7 Dynamic Review

4.8 Critical Discussions on PCM Models and Their Validation

References

Chapter 5: Dynamic Modeling of Current-Output Converters

5.1 Introduction

5.2 Dynamic Modeling

5.3 Source and Load Interactions

5.4 Impedance-Based Stability Issues

5.5 Dynamic Review

References

Chapter 6: Control Design Issues in Voltage-Fed DC–DC Converters

6.1 Introduction

6.2 Developing Switching and Average Models

6.3 Factors Affecting Transient Response

6.4 Remote Sensing

6.5 Simple Control Design Method

6.6 PCM-Controlled Superbuck Converter: Experimental Examples

6.7 Concluding Remarks

References

Part Three: Current-Fed Converters

Chapter 7: Introduction to Current-Fed Converters

7.1 Introduction

7.2 Duality Transformation Basics

7.3 Duality-Transformed Converters

7.4 Input Capacitor-Based Converters

References

Chapter 8: Dynamic Modeling of DDR-Controlled CF Converters

8.1 Introduction

8.2 Dynamic Models

8.3 Source and Load Interactions

8.4 Impedance-Based Stability Assessment

8.5 Output-Voltage Feedforward

8.6 Dynamic Review

References

Chapter 9: Dynamic Modeling of PCM/PVM-Controlled CF Converters

9.1 Introduction

9.2 Duty-Ratio Constraints and Dynamic Models under PCM Control

9.3 Duty-Ratio Constraints and Dynamic Models under PVM Control

9.4 Concluding Remarks

References

Chapter 10: Introduction to Photovoltaic Generator

10.1 Introduction

10.2 Solar Cell Properties

10.3 PV Generator

10.4 MPP Tracking Methods

10.5 MPP Tracking Design Issues

10.6 Concluding Remarks

References

Chapter 11: Photovoltaic Generator Interfacing Issues

11.1 Introduction

11.2 Centralized PV System Architecture

11.3 Distributed PV System Architectures

11.4 PV Generator-Induced Effects on Interfacing-Converter Dynamics

11.5 Stability Issues in PV Generator Interfacing

11.6 Control Design Issues

References

Part Four: Three-Phase Grid-Connected Converters

Chapter 12: Dynamic Modeling of Three-Phase Inverters

12.1 Introduction

12.2 Dynamic Model of Voltage-Fed Inverter

12.3 Dynamic Model of Current-Fed Inverter

12.4 Source-Affected Dynamics of Current-Fed Inverter

12.5 Dynamic Model of Current-Fed Inverter with LCL-Filter

12.6 Summary

Appendix 12.A

References

Chapter 13: Control Design of Grid-Connected Three-Phase Inverters

13.1 Introduction

13.2 Synchronous Reference Frame Phase-Locked-Loop

13.3 AC Current Control

13.4 Decoupling Gains

13.5 Grid Voltage Feedforward

13.6 Cascaded Control Scheme in Current-Fed Inverters

13.7 Case Study: Instability Due to RHP-Pole

13.8 Summary

References

Chapter 14: Reduced-Order Closed-Loop Modeling of Inverters

14.1 Introduction

14.2 Reduced-Order Model of Voltage-Fed Inverter

14.3 Reduced-Order Model of Current-Fed Inverter with L-Type Filter

14.4 Closed-Loop Model of Current-Fed Inverter with LC-Type Filter

14.5 Summary

References

Chapter 15: Multivariable Closed-Loop Modeling of Inverters

15.1 Introduction

15.2 Full-Order Model of Current-Fed Inverter with L-Type Filter

15.3 Experimental Verification of Admittance Model

15.4 Full-Order Model of Current-Fed Inverter with LCL-Type Filter

15.5 Summary

References

Chapter 16: Impedance-Based Stability Assessment

16.1 Introduction

16.2 Modeling of Three-Phase Load Impedance in the dq-Domain

16.3 Impedance-Based Stability Criterion

16.4 Case Studies

16.5 Summary

References

Chapter 17: Dynamic Modeling of Three-Phase Active Rectifiers

17.1 Introduction

17.2 Open-Loop Dynamics

17.3 Verification of Open-Loop Model

17.4 Experimental Results

17.5 Summary

References

Index

End User License Agreement

List of Tables

Table 4.1

Table 4.2

Table 12.1

Table 12.2

Table 12.3

Table 12.4

Table 12.5

Table 13.1

Table 13.2

Table 14.1

Table 15.1

Table 15.2

Table 15.3

Table 15.4

Table 17.1

List of Illustrations

Figure 1.1

Figure 1.2

Figure 1.3

Figure 1.4

Figure 1.5

Figure 1.6

Figure 1.7

Figure 1.8

Figure 1.9

Figure 1.10

Figure 1.11

Figure 1.12

Figure 1.13

Figure 1.14

Figure 1.15

Figure 1.16

Figure 1.17

Figure 1.18

Figure 1.19

Figure 1.20

Figure 1.21

Figure 1.22

Figure 1.23

Figure 1.24

Figure 1.25

Figure 1.26

Figure 1.27

Figure 1.28

Figure 2.1

Figure 2.2

Figure 2.3

Figure 2.4

Figure 2.5

Figure 2.6

Figure 2.7

Figure 2.8

Figure 2.9

Figure 2.10

Figure 2.11

Figure 2.12

Figure 2.13

Figure 2.14

Figure 2.15

Figure 2.16

Figure 2.17

Figure 2.18

Figure 2.19

Figure 2.20

Figure 2.21

Figure 2.22

Figure 2.23

Figure 2.24

Figure 2.25

Figure 2.26

Figure 2.27

Figure 2.28

Figure 2.29

Figure 2.30

Figure 2.31

Figure 2.32

Figure 2.33

Figure 2.34

Figure 2.35

Figure 2.36

Figure 2.37

Figure 2.38

Figure 2.39

Figure 2.40

Figure 2.41

Figure 2.42

Figure 2.43

Figure 2.44

Figure 2.45

Figure 2.46

Figure 2.47

Figure 2.48

Figure 2.49

Figure 2.50

Figure 2.51

Figure 2.52

Figure 2.53

Figure 2.54

Figure 2.55

Figure 2.56

Figure 2.57

Figure 2.58

Figure 2.59

Figure 2.60

Figure 2.61

Figure 2.62

Figure 2.63

Figure 2.64

Figure 2.65

Figure 2.66

Figure 2.67

Figure 2.68

Figure 2.69

Figure 2.70

Figure 2.71

Figure 2.72

Figure 2.73

Figure 2.74

Figure 2.75

Figure 2.76

Figure 2.77

Figure 2.78

Figure 2.79

Figure 2.80

Figure 2.81

Figure 2.82

Figure 2.83

Figure 2.84

Figure 2.85

Figure 2.86

Figure 2.87

Figure 2.88

Figure 2.89

Figure 2.90

Figure 3.1

Figure 3.2

Figure 3.3

Figure 3.4

Figure 3.5

Figure 3.6

Figure 3.7

Figure 3.8

Figure 3.9

Figure 3.10

Figure 3.11

Figure 3.12

Figure 3.13

Figure 3.14

Figure 3.15

Figure 3.16

Figure 3.17

Figure 3.18

Figure 3.19

Figure 3.20

Figure 3.21

Figure 3.22

Figure 3.23

Figure 3.24

Figure 3.25

Figure 3.26

Figure 3.27

Figure 3.28

Figure 3.29

Figure 3.30

Figure 3.31

Figure 3.32

Figure 3.33

Figure 4.1

Figure 4.2

Figure 4.3

Figure 4.4

Figure 4.5

Figure 4.6

Figure 4.7

Figure 4.8

Figure 4.9

Figure 4.10

Figure 4.11

Figure 4.12

Figure 4.13

Figure 4.14

Figure 4.15

Figure 4.16

Figure 4.17

Figure 4.18

Figure 4.19

Figure 4.20

Figure 4.21

Figure 4.22

Figure 4.23

Figure 4.24

Figure 4.25

Figure 4.26

Figure 4.27

Figure 4.28

Figure 4.29

Figure 4.30

Figure 4.31

Figure 4.32

Figure 4.33

Figure 4.34

Figure 4.35

Figure 4.36

Figure 4.37

Figure 5.1

Figure 5.2

Figure 5.3

Figure 5.4

Figure 5.5

Figure 5.6

Figure 5.7

Figure 5.8

Figure 6.1

Figure 6.2

Figure 6.3

Figure 6.4

Figure 6.5

Figure 6.6

Figure 6.7

Figure 6.8

Figure 6.9

Figure 6.10

Figure 6.11

Figure 6.12

Figure 6.13

Figure 6.14

Figure 6.15

Figure 6.16

Figure 6.17

Figure 6.18

Figure 6.19

Figure 6.20

Figure 6.21

Figure 6.22

Figure 6.23

Figure 6.24

Figure 6.25

Figure 6.26

Figure 6.27

Figure 6.28

Figure 6.29

Figure 6.30

Figure 6.31

Figure 6.32

Figure 6.33

Figure 6.34

Figure 6.35

Figure 6.36

Figure 6.37

Figure 6.38

Figure 6.39

Figure 6.40

Figure 6.41

Figure 6.42

Figure 6.43

Figure 6.44

Figure 6.45

Figure 6.46

Figure 6.47

Figure 6.48

Figure 6.49

Figure 6.50

Figure 6.51

Figure 6.52

Figure 6.53

Figure 6.54

Figure 6.55

Figure 6.56

Figure 6.57

Figure 6.58

Figure 6.59

Figure 6.60

Figure 6.61

Figure 6.62

Figure 6.63

Figure 6.64

Figure 6.65

Figure 6.66

Figure 6.67

Figure 7.1

Figure 7.2

Figure 7.3

Figure 7.4

Figure 7.5

Figure 7.6

Figure 7.7

Figure 7.8

Figure 7.9

Figure 7.10

Figure 7.11

Figure 7.12

Figure 7.13

Figure 7.14

Figure 7.15

Figure 7.16

Figure 8.1

Figure 8.2

Figure 8.3

Figure 8.4

Figure 8.5

Figure 8.6

Figure 8.7

Figure 8.8

Figure 8.9

Figure 8.10

Figure 8.11

Figure 8.12

Figure 8.13

Figure 8.14

Figure 8.15

Figure 8.16

Figure 8.17

Figure 8.18

Figure 8.19

Figure 8.20

Figure 9.1

Figure 9.2

Figure 9.3

Figure 9.4

Figure 9.5

Figure 9.6

Figure 9.7

Figure 9.8

Figure 10.1

Figure 10.2

Figure 10.3

Figure 10.4

Figure 10.5

Figure 10.6

Figure 10.7

Figure 10.8

Figure 10.9

Figure 10.10

Figure 10.11

Figure 10.12

Figure 10.13

Figure 10.14

Figure 10.15

Figure 10.16

Figure 10.17

Figure 10.18

Figure 10.19

Figure 10.20

Figure 10.21

Figure 10.22

Figure 10.23

Figure 10.24

Figure 10.25

Figure 10.26

Figure 10.27

Figure 10.28

Figure 10.29

Figure 10.30

Figure 10.31

Figure 10.32

Figure 10.33

Figure 10.34

Figure 10.35

Figure 10.36

Figure 10.37

Figure 10.38

Figure 10.39

Figure 11.1

Figure 11.2

Figure 11.3

Figure 11.4

Figure 11.5

Figure 11.6

Figure 11.7

Figure 11.8

Figure 11.9

Figure 11.10

Figure 11.11

Figure 11.12

Figure 11.13

Figure 11.14

Figure 11.15

Figure 11.16

Figure 11.17

Figure 11.18

Figure 11.19

Figure 11.20

Figure 11.21

Figure 11.22

Figure 11.23

Figure 11.24

Figure 11.25

Figure 11.26

Figure 11.27

Figure 11.28

Figure 11.29

Figure 11.30

Figure 11.31

Figure 11.32

Figure 11.33

Figure 11.34

Figure 11.35

Figure 12.1

Figure 12.2

Figure 12.3

Figure 12.4

Figure 12.5

Figure 12.6

Figure 12.7

Figure 12.8

Figure 12.9

Figure 12.10

Figure 12.11

Figure 12.12

Figure 12.13

Figure 12.14

Figure 12.15

Figure 12.16

Figure 12.17

Figure 12.18

Figure 12.19

Figure 12.20

Figure 12.21

Figure 12.22

Figure 12.23

Figure 12.24

Figure 12.25

Figure 12.26

Figure 12.27

Figure 12.28

Figure 12.29

Figure 12.30

Figure 12.31

Figure 12.32

Figure 12.33

Figure 12.34

Figure 13.1

Figure 13.2

Figure 13.3

Figure 13.4

Figure 13.5

Figure 13.6

Figure 13.7

Figure 13.8

Figure 13.9

Figure 13.10

Figure 13.11

Figure 13.12

Figure 13.13

Figure 13.14

Figure 13.15

Figure 13.16

Figure 13.17

Figure 13.18

Figure 13.19

Figure 13.20

Figure 13.21

Figure 13.22

Figure 13.23

Figure 13.24

Figure 13.25

Figure 13.26

Figure 13.27

Figure 13.28

Figure 13.29

Figure 13.30

Figure 13.31

Figure 13.32

Figure 13.33

Figure 13.34

Figure 13.35

Figure 13.36

Figure 13.37

Figure 13.38

Figure 13.39

Figure 13.40

Figure 13.41

Figure 13.42

Figure 13.43

Figure 13.44

Figure 13.45

Figure 13.46

Figure 13.47

Figure 13.48

Figure 13.49

Figure 13.50

Figure 13.51

Figure 13.52

Figure 13.53

Figure 13.54

Figure 13.55

Figure 13.56

Figure 13.57

Figure 13.58

Figure 13.59

Figure 13.60

Figure 13.61

Figure 13.62

Figure 13.63

Figure 13.64

Figure 13.65

Figure 13.66

Figure 14.1

Figure 14.2

Figure 14.3

Figure 14.4

Figure 14.5

Figure 14.6

Figure 14.7

Figure 14.8

Figure 14.9

Figure 14.10

Figure 14.11

Figure 14.12

Figure 14.13

Figure 14.14

Figure 14.15

Figure 14.16

Figure 14.17

Figure 14.18

Figure 14.19

Figure 14.20

Figure 14.21

Figure 14.22

Figure 14.23

Figure 14.24

Figure 14.25

Figure 14.26

Figure 14.27

Figure 14.28

Figure 14.29

Figure 14.30

Figure 14.31

Figure 14.32

Figure 14.33

Figure 14.34

Figure 14.35

Figure 14.36

Figure 14.37

Figure 14.38

Figure 14.39

Figure 14.40

Figure 14.41

Figure 14.42

Figure 14.43

Figure 14.44

Figure 14.45

Figure 14.46

Figure 14.47

Figure 14.48

Figure 15.1

Figure 15.2

Figure 15.3

Figure 15.4

Figure 15.5

Figure 15.6

Figure 15.7

Figure 15.8

Figure 15.9

Figure 15.10

Figure 15.11

Figure 15.12

Figure 15.13

Figure 15.14

Figure 15.15

Figure 15.16

Figure 15.17

Figure 15.18

Figure 15.19

Figure 15.20

Figure 15.21

Figure 15.22

Figure 15.23

Figure 15.24

Figure 15.25

Figure 15.26

Figure 15.27

Figure 15.28

Figure 15.29

Figure 16.1

Figure 16.2

Figure 16.3

Figure 16.4

Figure 16.5

Figure 16.6

Figure 16.7

Figure 16.8

Figure 16.9

Figure 16.10

Figure 16.11

Figure 16.12

Figure 16.13

Figure 16.14

Figure 16.15

Figure 16.16

Figure 16.17

Figure 16.18

Figure 17.1

Figure 17.2

Figure 17.3

Figure 17.4

Figure 17.5

Figure 17.6

Figure 17.7

Figure 17.8

Figure 17.9

Figure 17.10

Figure 17.11

Figure 17.12

Figure 17.13

Figure 17.14

Figure 17.15

Guide

Cover

Table of Contents

Begin Reading

Part 1

Chapter 1

Pages

iii

iv

xiii

xiv

xv

xvi

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

121

122

123

124

125

126

127

128

129

130

131

132

133

134

135

136

137

138

139

140

141

142

143

144

145

146

147

148

149

150

151

152

153

154

155

156

157

158

159

160

161

162

163

164

165

166

167

168

169

170

171

172

173

174

175

176

177

178

179

180

181

182

183

184

185

186

187

188

189

190

191

192

193

194

195

196

197

198

199

200

201

202

203

204

205

206

207

208

209

210

211

212

213

214

215

216

217

218

219

220

221

222

223

224

225

226

227

228

229

230

231

232

233

234

235

236

237

238

239

240

241

242

243

244

245

246

247

248

249

250

251

252

253

254

255

256

257

258

259

260

261

262

263

264

265

266

267

268

269

270

271

272

273

274

275

276

277

278

279

280

281

282

283

284

285

286

287

288

289

290

291

292

293

294

295

296

297

298

299

300

301

302

303

304

305

306

307

308

309

310

311

312

313

314

315

316

317

318

319

320

321

322

323

324

325

326

327

328

329

330

331

332

333

334

335

336

337

338

339

340

341

342

343

344

345

346

347

348

349

350

351

352

353

354

355

356

357

358

359

360

361

362

363

364

365

366

367

368

369

370

371

372

373

374

375

376

377

378

379

380

381

382

383

384

385

386

387

388

389

390

391

392

393

394

395

396

397

398

399

400

401

402

403

404

405

406

407

408

409

410

411

412

413

414

415

416

417

418

419

420

421

422

423

424

425

426

427

428

429

430

431

432

433

434

435

436

437

438

439

440

441

442

443

444

445

446

447

448

449

450

451

452

453

454

455

456

457

458

459

460

461

462

463

464

465

466

467

468

469

470

471

472

473

474

475

476

477

478

479

480

481

482

483

484

485

486

487

488

489

490

491

492

493

494

495

496

497

498

499

500

501

502

503

504

505

506

507

508

509

510

511

512

513

514

515

516

517

518

519

520

521

522

523

524

525

526

527

528

529

530

531

532

533

534

535

536

537

538

539

540

541

542

543

544

545

546

547

548

549

550

551

552

553

554

555

556

557

558

559

560

561

562

563

564

565

566

567

568

569

570

571

572

573

574

575

576

577

578

579

580

581

582

583

584

585

586

587

588

589

590

591

592

593

594

595

596

597

598

599

600

601

602

603

604

605

606

607

608

609

610

611

612

613

614

615

616

617

618

619

620

621

622

623

624

625

626

627

628

629

630

631

632

633

634

635

636

637

638

639

640

641

642

643

644

645

646

647

648

649

650

651

652

653

654

655

656

657

658

659

660

661

662

663

664

665

666

667

668

669

670

671

672

673

674

675

676

677

678

679

680

681

682

683

684

685

686

687

688

689

690

691

692

693

694

695

696

697

698

699

700

701

702

Power Electronic Converters

Dynamics and Control in Conventional and Renewable Energy Applications

Teuvo Suntio, Tuomas Messo, and Joonas Puukko

All books published by Wiley-VCH are carefully produced. Nevertheless, authors, editors, and publisher do not warrant the information contained in these books, including this book, to be free of errors. Readers are advised to keep in mind that statements, data, illustrations, procedural details or other items may inadvertently be inaccurate.

Library of Congress Card No.: applied for

British Library Cataloguing-in-Publication Data

A catalogue record for this book is available from the British Library.

Bibliographic information published by the Deutsche Nationalbibliothek

The Deutsche Nationalbibliothek lists this publication in the Deutsche Nationalbibliografie; detailed bibliographic data are available on the Internet at <http://dnb.d-nb.de>.

© 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Boschstr. 12, 69469 Weinheim, Germany

All rights reserved (including those of translation into other languages). No part of this book may be reproduced in any form – by photoprinting, microfilm, or any other means – nor transmitted or translated into a machine language without written permission from the publishers. Registered names, trademarks, etc. used in this book, even when not specifically marked as such, are not to be considered unprotected by law.

Print ISBN: 978-3-527-34022-4

ePDF ISBN: 978-3-527-69851-6

ePub ISBN: 978-3-527-69853-0

Mobi ISBN: 978-3-527-69854-7

oBook ISBN: 978-3-527-69852-3

Preface

Rigid voltage sources, such as an ideal grid, an output-voltage feedback-controlled converter, and a storage battery, have dominated as input sources for a long time. As a consequence, the scholars and engineers have learned every detail and developed a multitude of power stages and control methods for the voltage domain. A common characteristic of these sources is that their output impedance is low in magnitude at low frequencies. From time to time, a term current-sourced converter has been used with a voltage-sourced converter in case there is an inductor connected in series with the voltage-type source. Unfortunately, such a converter has no explicit relation to the current source as an input source. However, duality implies that there also exist sources that can be classified as real current sources, that is, sources that have an output impedance, which is high in magnitude.

Since the last decade, people have started paying more and more attention on renewable energy sources for providing pollution-free energy and ensuring energy availability also in the future. Usually, most of the power electronic converters applied in interfacing the renewable energy sources into power grid in grid-feeding mode are to be considered as current-fed converters due to the feedback control of DC voltage. Despite the real nature of the input source, the scholars and engineers still like to consider them as voltage sources and justify their opinions by means of Norton–Thevenin transformation. The dual nature of the photovoltaic generators (i.e., current and voltage at specific operation points of their current–voltage curve) makes them an input source that may be too confusing for an engineer to analyze and thus the analysis will be performed in the familiar voltage domain even though such a power source will significantly affect the dynamic behavior of the converters connected at their output terminals. The long history of voltage sources as the dominating input source has created a situation, which has prevented the full understanding of the special features introduced by the current sources as input sources. This is quite understandable, because the most difficult learning process is to learn out from the past.

This book contains material from both of the domains by using the same power stage powered either by the rigid voltage or the current source. The differences in the dynamic behavior of the converters in different domains are explicitly shown including also comprehensive analyses of the source and load interactions in DC–DC converter as well as in grid-connected three-phase converters. Similar material cannot be found from any available book and the material in scientific papers is scarce and may be hard to identify from the vast number of published papers.

Many individuals have helped us to create the book during the past 20 years in academy. Most of those individuals are our past Ph.D. students and colleagues at TUT, who have created new knowledge during the research projects we have conducted together. We appreciate very much the Finnish industry and funding organizations, who have helped us to fund the research.

Tampere University of TechnologyTampere, FinlandTeuvo Suntio

Tampere University of TechnologyTampere, FinlandTuomas Messo

ABB OyHelsinki, FinlandJoonas Puukko

About the Authors

Teuvo Suntio received his Ph.D. degree in electrical engineering in 1992 from Helsinki University of Technology, Finland. After several R&D engineering and managerial positions during the 22 years in Power Electronics Industry, he accepted a post as a Professor in 1998 in the Electronics Laboratory at University of Oulu, Finland, before moving to Department of Electrical Engineering, Tampere University of Technology in 2004, which is the post he still holds. Professor Suntio's current research interests include dynamic characterization and control of power electronic converters and systems, especially in renewable energy applications. He holds several international patents and has authored or coauthored over 230 international journal and conference publications. He is a Senior Member of IEEE, and has served as an associate editor in IEEE Transactions on Power Electronics since 2010.

Tuomas Messo was born in 1985 in Hämeenlinna, Finland. He finalized his M.Sc. and Ph.D. degrees in electrical engineering at Tampere University of Technology (TUT), Tampere, Finland in 2011 and 2014, respectively.

In 2014–2015, he worked as Post-Doctoral Researcher at TUT and in 2016 he was appointed as an Assistant Professor (Tenure Track) in the field of power electronics. He is currently working at the Laboratory of Electrical Energy Engineering at TUT where he carries out lecturing, research, and supervision of electrical engineering students of all degrees.

His main research interests include dynamic modeling of power converters in renewable energy applications and smart grids, impedance-based stability analysis, frequency-domain measurements, control design, and stability analysis of control systems.

Joonas Puukko was born in Helsinki, Finland. He has M.Sc. and Ph.D. degrees (both with distinction) in electrical engineering from the Tampere University of Technology, Tampere, Finland.

He was previously working at ABB Solar Inverters in Helsinki, Finland and ABB Corporate Research Raleigh, NC, USA. At the moment, he is with ABB High Power Drives in Helsinki, Finland. His research interests include power electronics in a range of applications from drives to interfacing of renewable energy systems with the utility grid. He has design experience in wide-bandgap semiconductors, high-frequency magnetics, and frequency-domain modeling/verification.

Part OneIntroduction

1Introduction

1.1 Introduction

For a long time, voltage-type sources such as storage battery, AC grid, and output-voltage-regulated converters have dominated as an input source for power electronic converters [1,2]. These sources are usually referred to as rigid sources, since the load has limited influence on their operating voltage. Both awareness on the depletion of fossil fuel reserves and their impact on the observed climate changes have accelerated the utilization of renewable energy sources, for example, wind and solar [3]. Effective large-scale utilization of these energy sources requires the use of grid-interfaced power electronic converters [4,5]. It has been recently concluded [6,7] that the power electronic converters used in the photovoltaic (PV) systems are essentially current-sourced converters because of the current-source properties of PV generator [8,9] forced by the input-side voltage feedback control [10,11]. At open loop, the static and dynamic properties of the integrating converter are determined by the operating region of the PV generator. The same also applies for the converters in wind energy systems. Another example of a perfect current source is superconducting magnetic energy storage (SMES) system, where a very large inductor serves as the energy storage element [12,13]. Even though the properties of the mentioned sources are already well known [14,15], they are still typically considered as voltage sources when designing the interfacing converter power stages [16,17] or analyzing their underlying dynamics [18–21] despite their current-type properties. The analysis method is usually justified by Norton/Thevenin transformation [20].

The existence of two different input source types implies that two different families of power electronic converters shall also exist, where the converters shall be referred to as voltage-fed (VF) (Figure 1.1) and current-fed (CF) (Figure 1.2) converters, possessing different steady-state and dynamic properties even though the power stage can be the same in both of the cases [7,22]. The term current source has already been widely used, for example, in Ref. [23–28], denoting a voltage-fed converter, where an inductor is placed on the input-side current path such as a boost-type converter [29] or two-inductor (super)buck converter [30]. Fuel cells as renewable energy sources [31] are such an input source, which can be considered to be either voltage or current sources due to their rather constant output impedance [32] and operation at the voltages less than the maximum power point [33]. Therefore, the elimination of the harmful low-frequency ripple can be performed by using either input current (i.e., voltage source) or input voltage (i.e., current source) feedback control [34].

Figure 1.1 VF converter. (a) VO mode. (b) CO mode. Source: Suntio 2014. Reproduced with permission of IEEE.

Figure 1.2 CF converter. (a) CO mode. (b) VO mode. Source: Suntio 2014. Reproduced with permission of IEEE.

On the load side, the output voltage of a converter shall not be taken automatically as an output variable, since this is true only when the converter serves as a typical power supply, regulating its output voltage. In case, the converter is used, for example, as a battery charger or grid-connected inverter, the output voltage is determined by the load-side source and hence output current shall be treated as an output variable. Therefore, the static input-to-output ratio , where denotes the steady-state duty cycle, shall be actually determined as the ratio of the input-terminal variable characterizing the input source and the same variable at the output terminal, that is, the voltage ratio in a VF converter and the current ratio in a CF converter. According to Figures 1.1 and 1.2, the converter may serve either as a VF or as a CF converter with voltage (VO) or current (CO) as its main output variable, depending on the application. In all the cases, the terminal constraints in terms of voltage and current levels remain unchanged. Reference [22] shows explicitly in theory and by experimental measurements that the dynamic behavior changes significantly application by application as demonstrated in Figure 1.3, where the measured frequency responses of the control-to-output transfer functions with different terminal source configurations are shown. Therefore, it is very important to identify the correct nature of the terminal sources when analyzing the dynamics of the converter, for example, for control design purposes, which is obvious when studying the frequency responses in Figure 1.3.

Figure 1.3 The frequency responses of a buck power stage converter when the terminal sources are varied (i.e., voltage-fed converters at voltage (vf/vo) and current (vf/co) output modes and current-fed converters at current (cf/co) and voltage (cf/vo) modes).

Every power electronic converter has unique internal dynamics, which will determine the obtainable transient dynamics and robustness of stability as well as its sensitivity to the external source and load impedances [35–37]. The internal dynamics can be represented by a certain set or sets of transfer functions, which are classified in circuit theory according to the network parameters [38] known as G (Figure 1.1a), Y (Figure 1.1b), H (Figure 1.2a), and Z (Figure 1.2b), respectively. The specific transfer functions can be directly modeled and measured as frequency responses only when the used terminal sources correspond to the ideal terminal sources given for each of the sets in Figures 1.1 and 1.2. Even if the concept of internal dynamics is basically well known (i.e., all effects from the source and load impedances are removed) [7,35], the tendency is still to use a resistor as a load [39] yielding load-affected models or measured frequency responses. A power stage fed by a certain input source under direct duty ratio (DDR) control tends to maintain the output mode the same as the input source (i.e., VF converters are inherently voltage sources at their output, and CF converters are current sources at their output). As a consequence, the internal transfer functions of such converters can be measured directly at open loop. The other possible output mode does not work at open loop due to violation of Kirchhoff's voltage or current law. The same also applies for the current-mode control, which changes the converter to be a current-output converter [40]. In such a case, the use of resistive load is well justified, but the internal transfer functions have to be computed from the load-affected transfer functions for being useful [7].

A large number of excellent power electronics textbooks are available, such as Refs [5,7,25,39,41–47], which are dedicated to the converters providing either DC–DC or DC–AC (AC–DC) conversion, or even both. None of these textbooks presents topics that treat the CF converters even if they exist or may even dominate within the specific application area covered in the specific books. The inclusion of the effect of source and load impedances on the converter dynamics is also usually left out by the topics covered in the books even if they are considered very important in practical applications.

The main goal of this book is to provide the missing information in order to complement the other textbooks as well as to present the base for the dynamic analysis of the converters in a general form, which can be utilized with both analytically derived transfer functions and the experimentally measured transfer functions. As a consequence, the potentials of the theoretical work are extended into practice and for the usage of practicing engineers.

The topics covered in the book are briefly discussed and clarified in the subsequent sections in order to familiarize the reader with the secrets of dynamic modeling, analysis, and control designs in both DC-voltage/current source and AC-voltage/current source domains. The mastering of these items requires quite consistent thinking ability as well as flexibility to change from one set of dynamic descriptions to another while moving on.

1.2 Implementation of Current-Fed Converters

There are actually three different methods to implement CF converters: (i) applying capacitive switching cells to construct CF converters [48] similarly as the inductive switching cells are applied, for example, in Refs [1,2], (ii) applying duality transformation methods [49–53], and (iii) adding a capacitor to the input terminal of a VF converter [54] to satisfy the terminal constraints imposed by the input current source [55]. The duality transformation yields CF converters, which retain the main static and dynamic properties characterizing the original VF converter [52]. The adding of a capacitor at the input terminal of a VF converter yields a CF converter having static and dynamic properties resembling the dual of the original converter, that is, a VF buck converter will have characteristics resembling a boost converter and vice versa [54].

As an example, the power stage of a VF buck converter and its dual, that is, the corresponding power stage of a CF buck converter, are given in Figures 1.4 and 1.5. In the original buck converter, the high-side switch conducts during the on-time and the low-side switch during the off-time. In the CF buck converter, the low-side switch conducts during the on-time and the high-side switch during the off-time. As both of the converters are buck-type converters, the ideal input-to-output relation or modulo .

Figure 1.4 VF buck converter.

Figure 1.5 CF buck converter.

It has been observed earlier that the VF-converter power stages used in the interfacing of PV generators exhibit peculiar properties, such as appearing of right-half-plane (RHP) zero in the control dynamics of buck power stage converter [56], unstable operation when the output voltage or current is tightly controlled [57], necessity to reduce the pulsewidth for increasing the output variables [58,59], and appearing of RHP pole when peak-current-mode (PCM) control is applied in a buck power-stage converter [60,61], and even the impedance-based stability assessment has to be performed differently compared to the VF converters [62]. The observed phenomena are good evidence for the necessity to fully take into account the used terminal sources as discussed in Ref. [22].

1.3 Dynamic Modeling of Power Electronic Converters

The methods to develop the required small-signal or dynamic models for the power electronic converters date back to the early 1970s [63] when the foundation for the state space averaging (SSA) method was laid down [64] and later modified to correctly capture the dynamics associated with the discontinuous conduction mode (DCM) of operation [65,66] as well as with the variable frequency operation [67,68]. The same methods also apply equally to modeling the dynamics of three-phase grid-connected power converters [69]. The SSA method is observed to produce accurate models up to half the switching frequency.

One of the most fundamental issues in performing the modeling in addition to the recognition of the correct input and output variables is that the state variables are to be considered as the time-varying average values within one switching cycle of the corresponding instantaneous values [66]. In continuous conduction mode (CCM), this is also true in the instantaneous state variables and, therefore, the averaged state space can be constructed by computing the required items directly by applying circuit theory. The continuity is also reflected as the known length of the on-time and off-time. In DCM, the instantaneous variables are not anymore necessarily continuous signals but rather pulsating signals, which is also reflected as the unknown length of off-time. Therefore, their time-varying average values have to be computed based on the wave shapes of their instantaneous values and used for computing the length of the unknown off-time. A number of variants are available for the basic SSA method in continuous time as well as in discrete time, which can also be used for obtaining the dynamic models but they do not offer usually such benefits, which would justify their usage in practical applications.

The original SSA method can be applied as such only to the converters, which operate in CCM under DDR control, which is also known as voltage-mode (VM) control [39]. The last term is not recommended, however, to be used, because it will mean in the future the internal control methods in a CF converter, where the feedback is taken from the capacitor voltage (i.e., peak voltage mode (PVM) or average voltage mode (AVM)) similarly as the current-mode controls (i.e., peak current (PCM) or average current (ACM)) in a VF converter. The dynamic models (i.e., the small-signal state space) induced by the DDR control will serve as the base for the modeling of the converters, where the internal feedback loops are used to affect the duty ratio generation, that is, the dynamics associated with the duty ratio. The modeling of those converters can be simply done by developing proper duty-ratio constraints, where the perturbed duty ratio is expressed as a function of the state and input variables of the converter [7]. In case of variable-frequency operation, the duty ratio is nonlinear and, therefore, the on-time of the switches has to be used as the control variable instead of duty ratio [7,68].

1.4 Linear Equivalent Circuits

As an outcome of the SSA modeling method [64], the dynamics of the associated converter was represented by means of the canonical equivalent circuit given in Figure 1.6, which is valid for a second-order or two-memory-element converter operating in CCM under DDR control. The structure and the circuit elements of the equivalent circuit can be found from the corresponding small-signal state space. Similar equivalent circuit can also be constructed for the higher order converters as well as for CF converters (see Figure 1.7) applying the same methodology. Figures 1.6 and 1.7 provide clear physical insight into the dynamic processes inside the converters as well as clearly indicate the differences the duality transformation produces in the converter. As being a linear representation of the converter, the effect of the source and load impedances can be computed by applying circuit theory, which is very important for understanding the dynamic behavior of the practical systems.

Figure 1.6 Canonical equivalent circuit for a second-order VF/VO converter.

Figure 1.7 Canonical equivalent circuit for a second-order CF/CO converter.

Similar equivalent circuits as in Figures 1.6 and 1.7 cannot be, however, constructed for the converters operating in DCM or containing internal feedbacks, for example, PCM control. More general equivalent circuit can be constructed based on the set of transfer functions comprising the network parameters G, Y, H, and Z, which can be utilized similarly as the canonical equivalent circuits in Figures 1.6 and 1.7 to assess the effect of nonideal source and load [7,70]. Figures 1.8 and 1.9 show such a generic equivalent circuit representing the dynamics of VF/VO DC–DC and a VF/CO DC–DC converters, respectively. On comparing the equivalent circuits in Figures 1.6 and 1.7 with the equivalent circuits in Figures 1.8 and 1.9, the main difference found between them is that the latter equivalent circuits present explicitly the main terminal characteristics of a converter. This information is actually very important for being able to fulfill the terminal constraints stipulated by the different input and output sources.

Figure 1.8 Generic equivalent circuit for a VF/VO converter.

Figure 1.9 Generic equivalent circuit for a CF/CO converter.

Similar equivalent circuits as in Figures 1.6 and 1.7 can also be constructed for the three-phase grid-connected converters by means of their small-signal state space given in the synchronous reference frame applying power invariant transformation (i.e., power-invariant d–q state space), as shown in Figures 1.10 and 1.11 [71,72]. The corresponding physical schematics are given in Figures 1.12and 1.13, respectively. According to Figures 1.12 and 1.13, the converters can be constructed from each other by changing the direction of power flow. This similarity is also visible in the corresponding equivalent circuits. These equivalent circuits would give the same physical insight as the corresponding DC–DC equivalent circuits.

Figure 1.10 Canonical equivalent circuit for a three-phase AC–DC converter.

Figure 1.11 Canonical equivalent circuit for a current-fed three-phase DC–AC converter.

Figure 1.12 Three-phase grid-connected rectifier.

Figure 1.13 Three-phase grid-connected current-fed inverter.

Similar equivalent circuits as in Figures 1.10 and 1.11 cannot be, however, constructed for the converters operating in DCM or containing internal feedbacks. Similarly, as in the case of DC–DC converters, the more general equivalent circuits can be constructed based on the set of transfer functions comprising the network parameters G, Y, H, and Z, which can be utilized similarly as the canonical equivalent circuits in Figures 1.10 and 1.11 to assess the effect of nonideal source and load [7,73]. Figure 1.14 shows such a generic equivalent circuit representing the dynamics of a three-phase grid-connected AC–DC converter, and Figure 1.15 shows a generic equivalent circuit representing the dynamics of a three-phase grid-connected current-fed inverter. On comparing the equivalent circuits in Figures 1.10 and 1.11 with the equivalent circuits in Figures 1.14 and 1.15, the main difference found between them is that the latter equivalent circuits present explicitly the main terminal characteristics of a converter. This information is actually very important for being able to fulfill the terminal constraints stipulated by the different input and output sources.

Figure 1.14 Generic equivalent circuit for a three-phase grid-connected VF/VO converter.

Figure 1.15 Generic equivalent circuit for a three-phase grid-connected CF/CO converter.

The variables of the equivalent circuits with a superscript s denote the three-phase variables transformed into the synchronous reference frame (SRF) composed of direct (d) and quadrature (q) components of the variables, respectively. The transfer functions represented with boldface letters denote a transfer function matrix composed of two or four discrete transfer functions. The computation of the effect of nonideal source and load has to be performed by applying matrix manipulation techniques instead of circuit theoretical methods [73].

The generic equivalent circuits are very flexible tools for solving the dynamic problems associated with the impedance-based interactions [37,71,74] as well as for assessing the stability in the practical interconnected systems [75,76]. The dynamic equivalent circuits as well as the corresponding matrix-form representations can be equally utilized by means of the model-based analytic transfer functions and the corresponding measured frequency responses or even by their combination.

1.5 Impedance-Based Stability Assessment

Stability assessment of a system composed of interconnected power electronic converters as well as passive impedance-like elements can be effectively performed at any interface within the system by means of the ratio of upstream and downstream impedances measured or predicted at the interface [7,22,63,75–84]. The method was originally launched in Refs [77,78] for designing stable input-filter converter systems. The ratio was named as minor loop gain, where the input-filter output impedance is the upstream impedance and the input impedance of the converter is the downstream impedance. The minor loop gain denotes the ratio of the upstream and downstream impedances. The stability of the interconnected system is retained when the minor loop gain satisfies Nyquist stability criterion. It has been later observed that the original minor loop gain is only valid for a certain type of interfaces, that is, the upstream subsystem is a voltage-type system and the downstream system a current-type system. A general definition for the construction of the minor loop gain is such that the numerator impedance shall be the internal impedance of the voltage-type subsystem and the denominator impedance shall be the internal impedance of the current-type subsystem [22,62,78].

The minor loop gain concept is nowadays applied commonly in assessing the stability and transient performance in interconnected power electronic systems. The concept of forbidden region was launched in Ref. [79], which ensures robust stability of the system if the minor loop gain stays out of the forbidden region. The forbidden region launched by Middlebrook in Refs [77,78] is a circle having radius of inverse of gain margin (GM) and the center at origin, as shown in Figure 1.16. Middlebrook's forbidden region was deemed to be too conservative, that is, occupying unnecessary amount of area in the complex plain [79]. As a consequence, new forbidden regions were developed for reducing the conservatism [79–84] such as ESAC (energy systems analysis consortium) [79], GMPM (gain margin phase margin) [80], and opposing argument [81] criteria illustrated in Figure 1.16.

Figure 1.16 Collection of forbidden regions in the complex plane according to Refs [77–84]. Source: Vesti 2013. Reproduced with permission of IEEE.

According to Figure 1.16, all the different criteria aim to maintain robust stability (i.e., acceptable transient performance) by requiring the minor loop gain to satisfy certain PM and GM conditions. Reference [75] proposed a new forbidden region by means of a circle having radius of inverse of maximum peak value allowed in the affected system transfer functions and the center at the point (−1,0) as depicted in Figure 1.17, which outperforms the other earlier launched forbidden regions in terms of occupied area in the complex plain. The forbidden region concept is applicable to DC and AC domain systems as well.

Figure 1.17 Maximum peak criteria (MPC)-based forbidden region versus EASC and GMPM regions [75]. Source: Vesti 2013. Reproduced with permission of IEEE.

1.6 Time Domain-Based Dynamic Analysis

Time domain-based dynamic analysis and control design are quite common in control engineering [85,86] and are also utilized in conjunction with the grid-connected power electronics applications [87]. The time domain responses do not, however, reveal the origin of the observed transient behavior or how close the system is for instability. Figure 1.18 shows the output-voltage transient behavior of a buck converter when a step change is applied in the load current without (Figure 1.18a) and with the input LC or EMI filters (Figure 1.18b and c). If both the original and EMI filter-affected responses were not known, then it would be very difficult to distinguish between the poor controller design and other external reasons, because the decaying oscillation at the output-voltage response would be similar with low margins (i.e., PM and GM) in the feedback loop.

Figure 1.18 Output-voltage response of a buck converter to a step change in load current.

Figure 1.19 shows the measured output-voltage feedback loop without and with the input EMI filter. According to Figure 1.19, the EMI filter has not caused such a change in the feedback loop, which would affect the transient response, that is, the PM and GM are not changed. Figure 1.20 shows the measured closed-loop output impedance of the converter, where the EMI filter has created a resonance, which actually initiates the decaying oscillation at the output-voltage response [88,89]. More specifically, the resonance at the output impedance is caused by the interacting EMI-filter output impedance and short-circuit input impedance of the converter [90].

Figure 1.19 The measured original and EMI-filter-affected output-voltage feedback loops.

Figure 1.20 Original and EMI-filter-affected closed-loop output impedances.

Figure 1.21 shows that the grid-connected inverter may become unstable when the control bandwidth of the phase locked loop (PLL) is increased under certain grid impedance conditions. PLL is used for synchronizing the inverter to grid. The reason for the instability is the tendency of the inverter output impedance to have negative resistor-like behavior at low frequencies, that is, at the frequencies lower than the PLL crossover frequency [91]. The frequency responses of the inverter output impedance and the grid impedance (Figure 1.22) can be used to reveal explicitly the problems associated with instability phenomenon. The time domain plot does not tell anything about the reasons behind the problem or how much the condition has to change that the instability will vanish or occur again.

Figure 1.21 Instability of three-phase grid-connected inverter induced by PLL control bandwidth.

Figure 1.22 Effect of the PLL bandwidth on the inverter output impedance.

It may be quite obvious that the time domain evidence does not suffice to proving the quality of design or the validity of the modifications for removing the problem. The frequency domain evidence will provide a medium to assess the robustness of the design as well as to reveal the risks left in the design for reoccurrence of the “removed” problem.

1.7 Renewable Energy System Principles

Large-scale utilization of the renewable energy sources such as solar PV, wind, and fuel cells necessitates the use of power electronic converters for providing the grid integration [4]. The solar PV power plants are either constructed by using one DC–AC stage (i.e., single stage) (Figure 1.23) or cascaded by using DC–DC and DC–AC stages (i.e., double stage) (Figure 1.24) [92]. The full-power converter wind energy and fuel cell systems are most often constructed by using double-stage converter schemes according to Figure 1.24 [31,93–95].

Figure 1.23 Single-stage renewable energy system principle.

Figure 1.24 Cascaded renewable energy system principle.

The basic operation mode of these systems in terms of grid connection is either grid-parallel (i.e., grid-feeding, grid-supporting) or grid-forming mode [96–98]. In grid-parallel operation mode, the inverter serves as current source, and the grid determines the level of AC voltage and frequency (Figures 1.25 and 1.26). Usually maximum available power in the renewable energy source is supplied into the grid applying different maximum power point (MPP) tracking algorithms [99–102]. A characteristic of the grid-parallel operation mode is that the outmost feedback loops of the power electronic converters are taken from the input terminal of the converters (see Figures 1.25 and 1.26).

Figure 1.25 Single-stage grid-parallel energy system.

Figure 1.26 Cascaded grid-parallel renewable energy system.

In grid-forming operation mode (i.e., standalone, off-grid, or islanding), the inverter serves as a voltage source taking care of both the voltage level and the frequency (Figures 1.27 and 1.28). The level of output power supplied into the system depends on the load of the system. A characteristic of the grid-forming mode is that the outmost feedback loops are taken from the output terminal of the power electronics converters (see Figures 1.27 and 1.28).

Figure 1.27 Single-stage grid-forming energy system.

Figure 1.28 Cascaded grid-forming renewable energy system.

The feedback arrangements mean that the power electronic converters in grid-parallel mode are CF/CO converters and in grid-forming mode VF/VO converters. The change of operating mode is usually required in renewable energy systems (i.e., from grid-parallel to grid-forming mode and back). The dynamic behavior of the converters will profoundly change depending on the operation mode, which has to be carefully considered when designing the control systems for ensuring stable operation [97].

1.8 Content Review

The book is divided into four parts as follows: Part One, comprising Chapters 1 and 2, is dedicated to the introduction as well as to the dynamic analysis and control design preliminaries in a generalized manner. Part Two, comprising Chapters 3–6, is dedicated to the dynamics of voltage-fed DC–DC converters. Part Three, comprising Chapters 7–11, is dedicated to the dynamics of current-fed DC–DC converters as well as to the properties of photovoltaic generator and its effects on the interfacing converter dynamics. Part Four, comprising Chapters 12–17, is dedicated to the dynamics and control of grid-connected three-phase VSI-type converters. The content of the subsequent chapters is briefly reviewed in order to clarify the message, which each chapter will deliver.

The conceptual and theoretical basis of the book is provided in Chapter 2 in a simple and practical manner without using difficult mathematical treatments, but at the same time in general form. The same theoretical formulas are repeated in explicit modes in the associated chapters if deemed to be necessary for understanding the message.

In Part Two, the dynamic modeling, analysis, and control of VF converters are treated. Chapter 3 provides the unified dynamic modeling of direct-on-time-controlled converters applied to the basic converters (i.e., buck, boost, and buck–boost) as well as to the superbuck or two-inductor buck converter in the fixed-frequency mode of operation. The dynamic models provided by Chapter 3 are utilized to model the dynamic behavior of the current-mode-controlled converters in Chapter 4. The similarity between PCM and ACM controls is clearly pointed out. The modeling of PCM control is also introduced in case of several simultaneous inductor-current-feedback arrangements as well as when coupled inductors are utilized. The source and load interactions in PCM- and DDR-controlled converters are compared and the origin of the differences is explained. Chapter 5 introduces the modeling of current-output converters based on the models of the VF/VO converters. The source and load interactions as well as impedance-based stability analysis are introduced and compared with the VF/VO converters. Chapter 6 is dedicated for the control design issues in VF converters. The factors affecting the load transient response are explicitly explained, which would facilitate the control design.

In Part Three, the implementation, dynamic modeling, analysis, and control of CF converters are treated. Chapter 7 provides the methods to implement CF converters applying duality transformation and adding necessary components at the input terminal for satisfying the terminal constraints imposed by the current-type input source. Chapter 8 provides the dynamic models of DDR-controlled basic CF converters implemented by duality-transformation methods or by adding a capacitor at the input terminal of a VF converter. Chapter 9 introduces the dynamic modeling of PCM- and PVM-controlled CF converters. Observed stability problems in conjunction with PCM control applied in PV interfacing converters are explicitly explained. The influence of the PCM and PVM controls in source and load interactions as well as impedance-base stability assessment are explicitly explained. Chapter 10 introduces the characteristics of PV generator as well as the MPP tracking methods and design constraints. Chapter 11 is dedicated to the photovoltaic generator interfacing problematics from the power electronics converter viewpoint, including the PV generator-induced effects on the dynamics of the interfacing converters as well as the associated stability issues.

In Part Four, the dynamic modeling, analysis, and control of grid-connected three-phase VSI-type converters are treated. Chapter 12 provides consistent methods to develop the dynamic models of voltage- and current-fed three-phase PWM inverters in synchronous reference frame (or dq-domain) by utilizing space vector theory. Chapter 13 is dedicated to applying the dynamic models to design the required control functions in an inverter. The effect of different control anomalies caused by the input terminal sources are explicitly treated as well. Chapter 14 introduces reduced-order dynamic modeling of the inverters to relax the high complexity of the inverter dynamics for achieving satisfactory dynamic descriptions applicable for control design. Chapter 15 provides the detailed models for analyzing the closed-loop dynamics of the inverter in multivariable environment. Chapter 16 provides detailed information on the impedance-ratio-based stability assessment methods applying generalized Nyquist stability criterion. Chapter 17